Records from 1990 to 2021. Most recent: inspection, 23 February 2021.
Inspection history · 51
23 February 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7144659
14 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7005885
31 May 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6699171
3 May 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6676162
12 June 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6441858
16 March 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6105776
24 February 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6094141
20 January 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6074323
5 December 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6052665
14 January 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5797752
1 October 2014
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4995875
20 March 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4819877
17 March 2014
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4815016
9 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4221737
14 January 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3664000
10 July 2009
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3610209
12 May 2009
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3473270
7 October 2008
Re-Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3340624
5 August 2008
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3289997
1 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3070694
2 July 2007
Internal Structural Exam · Deficiency Check · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2980809
15 July 2006
Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2763336
21 June 2006
COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2687296
21 June 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2687339
9 March 2005
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2304955
23 June 2004
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2106685
6 August 2003
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1868504
18 June 2002
Hull Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1632512
5 June 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461405
7 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50199
24 May 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1391304
24 May 1999
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1365225
9 April 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788284
23 April 1998
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470437
8 February 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 156578
19 March 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385926
17 June 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417972
21 December 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1182325
3 March 1995
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374216
22 October 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1156690
26 August 1993
Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467388
21 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1152146
16 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262045
4 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947734
23 December 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666035
14 November 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666039
9 October 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666043
6 August 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934496
31 January 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1239857
18 December 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901359
25 April 1990
Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920919
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 February 2021
Resolved
STBD Main diesel engine oil lines were cracked.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2021
Resolved 24 February 2021
Resolution: Oil lines were replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 February 2021
Resolved
Gasket on emergency escape hatch for the engine room does not make contact with the knife edge.
Replace gasket and ensure proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 February 2021
Resolved 24 February 2021
Resolution: gaskets were replaced. hatch functioned as designed and sealed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 February 2021
Resolved
various dead end wires were found in the engine room.
remove dead end wires.
Action required: 10 - Deficiency Rectified
Due 23 February 2021
Resolved 23 February 2021
Resolution: dead end wires removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 February 2021
Resolved
guards were not installed on rotating machinery in the engine room.
install guards on the outboard side of MDE's.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 24 February 2021
Resolution: guards were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2019
Resolved
Each vessel must be fitted with an appropriate number of life-jackets for the number of persons carried. Vessel found with 01 life-jacket not servicable. Corrcct to the satisfaction of attending CG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 June 2019
Resolution: Verified appropriate number of life-jackets for the number of persons carried.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 31 May 2019
Resolved
Vessel must carry one rescue boat due to inablility to maneuver to recover a person from the water. Vessel's rescue boat engine become inoperable shortly in to witnessing test. Correcct to satisfaction of attending CG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 June 2019
Resolution: Got underway verified workboat engine working properly.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 31 May 2019
Resolved
each vessel must be equipped with a public address system. Public address system was not audible on back deck. Correct to the satisfaction of attending CG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 June 2019
Resolution: MI witnessed proper operation of PA.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 31 May 2019
Resolved
No person may operate a U.S. non-oceangoing ship in the navigable waters of the United States, unless it has the capacity to retain on board all oily mixtures. Vessel is currently fitted with an automatic independint electric submersible bilge pump in an oily engine bay presenting a pollution hazard. Correct to the satisfction of attending CG MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 June 2019
Resolution: Pump removed and pipe blanked off.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 January 2016
Resolved
Ring buoy not labeled with hailing port.
Action required: 705 - Other - as specified
Resolved 3 February 2016
Resolution: Vessel provided hailing port to life ring.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 January 2016
Resolved
Cableway support not present in engine room over fwd passageway.
Action required: 705 - Other - as specified
Resolved 3 February 2016
Resolution: Vessel provided cableway supports.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 January 2016
Resolved
Missing Labeling
Action required: 705 - Other - as specified
Resolved 3 February 2016
Resolution: Labeling provided.
Engineering › Steering Gear System › Rudder
Issued 14 January 2016
Resolved
Port rudder seal missing bolt.
Action required: 705 - Other - as specified
Resolved 3 February 2016
Resolution: Vessel provided bolt.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2014
Resolved
Provide machinery guard for PTO on port engine.
Due 25 March 2014
Resolved 19 March 2014
Resolution: Installed machinery guards.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2014
Resolved
Provide junction box for dead end wiring for STBD engine starter
Due 25 March 2014
Resolved 19 March 2014
Resolution: Installed junction box for dead end wiring.
Engineering › Fuel Oil Service System › Piping
Issued 17 March 2014
Resolved
Provide brackets and chaffing gear for all fuel piping in engine room.
Due 25 March 2014
Resolved 19 March 2014
Resolution: Bracketed all fuel and hydraulic lines in the engine room.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 March 2014
Resolved
EPIRB battery and hydrostatic release expired. Vessel has a lakes, bays, ands sounds route - equipment not required but is on board.
Action required: 705 - Other - as specified
Resolved 19 March 2014
Resolution: EPIRB battery and hydrostatic release were both renewed.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 17 March 2014
Resolved
Provide 60 month crane test IAW 107.260. Test must be performed in the presence of a Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 10 July 2014
Resolved 15 December 2014
Resolution: Witnessed satisfactory 5 year crane test. See Act#5028855 for results
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2014
Resolved
Portable extension cord in the bridge was used as permanent installation.
Due 17 March 2014
Resolved 17 March 2014
Resolution: Removed portable extension cord.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 March 2014
Resolved
Main deck life buoy waterlight not properly wired.
Due 17 March 2014
Resolved 17 March 2014
Resolution: Rewired the life buoy waterlight.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 March 2014
Resolved
During annual inspection, found vessel to be 59 days past the last 3 month grace period for their anniversary date. MI talked with vsl rep and operations rep and explained the 90 day window on either side of the anniversary date. Explained the vsl must get an inspection regardless if the vsl is working or not.
Condition: Invalid
Due 17 March 2014
Resolved 17 March 2014
Resolution: Vsl passed annual inspection, issued eight (08) defs. See inspection results for details.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 12 May 2009
Resolved
Repair handrails on Port side Pilot House deck
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2009
Resolved 12 May 2009
Resolution: Welded handrails on Port side Pilot House deck
Lifesaving › Rescue Boat › Propeller
Issued 12 May 2009
Resolved
Replace propeller due to damage
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2009
Resolved 12 May 2009
Resolution: Replaced propeller
Lifesaving › Rescue Boat › Propeller
Issued 12 May 2009
Resolved
Replace propeller due to damage
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2009
Resolved 12 May 2009
Resolution: Replaced propeller
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 October 2008
Resolved
Emergency fuel shut off valve on center tank not operable, needs to be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Resolution: New shut off valve installed and checked by marine inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 October 2008
Resolved
Port bilge alarm inop, needs to work properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Resolution: Alarm corrected and tested sat, witnessed by CG marine inspector.
Engineering › Lubricating Oil Service System › Piping
Issued 7 October 2008
Resolved
Pipe support missing on hydraulic supply line to wireline unit. Install support for piping.
Action required: 705 - Other - as specified
Resolved 15 December 2008
Resolution: Pipe support installed and viewed by marine inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 October 2008
Resolved
Due to the amount of time laid up in shipyard, crew must conduct and log a complete set of drills prior to going back to work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2008
Resolution: Vessel rep got u/w with crew to ensure all drills conducted prior to sail and logged.
Construction/Loadline › Hull › Bottom Plating
Issued 5 August 2008
Resolved
Port bottom hull adjacent to crane support holed and taking on water. Vessel to cut wasted metal and insert for CG inspection.
Action required: 705 - Other - as specified
Resolved 10 December 2008
Resolution: Vessel went to shipyard and had approx 40% of the hull replaced with new plate. All repairs tested SAT.
Communications › Radio Communications › EPIRB
Issued 5 August 2008
Resolved
Provide working registered EPIRB
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2008
Resolution: EPIRB on board at RIN
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 August 2008
Resolved
Repair all Emergency Electrical lighting
Action required: 705 - Other - as specified
Resolved 10 December 2008
Resolution: All e-lighting properly functioning during RIN.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 August 2008
Resolved
Provide current light list, tide currents, charts
Action required: 705 - Other - as specified
Resolved 5 December 2016
Resolution: All pubs on board at RIN.
Lifesaving › Lifefloat › Lifeline
Issued 2 July 2007
Resolved
Properly splice
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 July 2007
Resolved
Provide Alcohol test strips.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 July 2007
Resolved
provide
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 July 2007
Resolved
run and log all drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2007
Fire Fighting › Means of Escape › Blocked
Issued 2 July 2007
Resolved
Provide means of escape(ladder) through overhead in main deck accomodation space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 21 June 2006
Resolved
Failure to secure type II MSD prior to operating vessel in area discharge of untreated sewage is prohibited by EPA. Overboard tank by-pass valve in open position, sewage discharged directly over board.
Action required: 705 - Other - as specified
Due 21 June 2006
Resolved 20 September 2006
Navigation
Issued 31 January 1991
Resolved
CONDUCT TEST AND SUBMIT MAGNETIC COMPASS DEVIATION TABLE TO [name withheld].
Condition: Unknown
Due 31 January 1991
Resolved 31 January 1991
Lifesaving
Issued 25 April 1990
Resolved
PROVIDE A U.S. COAST GUARD APPROVED RESCUE BOAT. SEE 46 CFR 180.10-35.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILE, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS. SEE 46 CFR 177.05-1.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT [name withheld] 46 CFR 177.05-1.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C. VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL ISRECEIVED. SEE 46 CFR 109.121.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Navigation
Issued 25 April 1990
Resolved
CONDUCT TEST AND SUBMIT MAGNETIC COMPASS DEVIATION TABLE TO [name withheld] 46 CFR 164.35 (C).
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Documentation
Issued 25 April 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER WASHINGTON, D.C. FOR REVIEW AND APPROVAL. SEE 46 CFR 170.075 AND 46 CFR 170.090.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990