Records from 2016 to 2025. Most recent: inspection, 10 February 2025.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 August 2018
Resolved
Means of control for flammable liquids in the space shall be provided. PSCO observed a 55 gallon drum of flammable products and a jug of gasoline for the rescue boat in the steering gear compartment.
SOLAS 74(a) 2004 cons. II-2/5.1.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 August 2018
Resolved 28 August 2018
Resolution: vessel moved flammable liquids to the proper space.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 28 August 2018
Resolved
Vessel is required to record visual inspections in accordance with the VGP. PSCO observed the visual inspections were not being recorded and crew was unaware of the requirements to conduct weekly checks while in U.S. Waters. PSCO conducted education with Captain and [name withheld] on VGP.
VGP parts 4.1.1, 4.1.1.1, and 4.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 August 2018
Resolved 28 August 2018
Lifesaving › Inflatable Liferafts › Painter
Issued 15 July 2016
Resolved
Beofre the ship leaves port and at all times during the voyage, all life-saving appliances shall be ready for immediate use. The PSCO observed the painter on all 4 life rafts attached to the wrong side of the hydrostatic release rendering the automatic inflation function inoperable. 74 SOLAS (a) III/20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 15 July 2016
Resolution: The Chief Mate corrected the painter arrangements on the spot.
Engineering › Steering Gear System › Pump
Issued 15 July 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a hydraulic oil leak from No. 2 main steering pump that was directed to a secondary temporary containment. 74 SOLAS (a) I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 21 July 2016
Resolution: Recieved class report that the ships crew renewed the seal on the hydraulic cylinder for the #2 steering pump and no more apparent leaks were noted.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 15 July 2016
Resolved
The SOLAS training manual shall contain the instructions and information on the operation and use of lifesaving equipment. PSCO found that the training manual did not contain the current life raft hydraulic release unit installed on four 16 person life rafts.
74 SOLAS (a) III/35
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 21 July 2016
Resolution: Recieved class report that the information on the liferaft hydrostatic release unit was added to the SOLAS Training manual and the crew was instructed on the use and installation of the unit.