PROGRESO is a 2005 freight ship. The Coast Guard has recorded 48 inspections since 2016, most recently in July 2026, along with 13 deficiencies and 13 operational controls, 1 with no removal date recorded.
Records from 2016 to 2026. Most recent: inspection, 30 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it2978 - Convention (Subpart B), Gross Ton 4716 - Dead Weight, Metric Ton 1314 - Convention (Subpart B), Net Ton 6597 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 48
30 July 2026PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8450320
21 January 2026PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8298452
23 July 2025PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8188610
11 April 2025Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8110239
3 April 2025PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8104734
29 November 2024Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8041211
18 November 2024Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8036358
8 November 2024Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8032538
5 November 2024Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8029690
29 October 2024Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8026255
24 October 2024Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8024230
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 July 2026Resolved
Two sets of steel ladders as widely separated as possible leading to doors in the upper part of the space similarly separated and from which access is provided to the open deck, in general one of these ladders shall provide continued fire shelter from the lower part of the space to a safe position outside the space. PSCO observed an opening cut out in the bulkhead of the emergency escape trunk leading from the main engineering space, allowing free movement of both smoke and flame. 74 Solas (97) II-2 45.3.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2026
Resolution: Class report attesting to repair and insulating to A-60 boundary requirements.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 July 2026Resolved
Where penetrations of watertight bulkheads and internal decks are necessary for access etc,. arrangements are to be made to maintain the watertight integrity. PSCO observed a bulkhead penetration in the engine room escape trunk leading to a hatch above the waterline.
74Solas(04) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2026
Resolution: Received class report attesting to repair of escape trunk.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 April 2025Resolved
Any required sprinkler, fire detection, and fire alarm system shall be capable of immediate operation at all times. PSCO observed plastic barrier over smoke detector above main generator, rendering it ineffective.
Action required: 10 - Deficiency Rectified
Due 5 April 2025
Resolved 5 April 2025
Resolution: Vsl removed cover.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 April 2025Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed electric cable running through steering gear watertight door through aft engine room, through door into air condition room, preventing all doors from closing.
Action required: 10 - Deficiency Rectified
Due 5 April 2025
Resolved 5 April 2025
Resolution: vsl removed cable running through class A door and secured door.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 April 2025Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed emergency generator in low-lube oil alarm condition when operated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2025
Resolved 11 April 2025
Resolution: vsl opened and cleaned the contact on the emergency generator. Emergency generator was tested and no low pressure alarm was observed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 September 2024Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCOs observed one bullet hole in the STBD side of the lifeboat in the vicinity of the helmsman's seat.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2024
Resolution: Vessel provided a class report that repairs were conducted and accepted by class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 May 2024Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas-tight and self-closing. PSCO observed that the class A-0 fire door leading from the main stairwell to the engine room did not self-close when in the fully open position.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Engineers on the PROGRESO worked to tighten the fitting on the hydraulic arm to the door. The casing had been loose and needed tightening to work properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2024Resolved
13101 - PROPULSION AND AUXILIARY MACHINERY - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO WAS ALERTED TO LOSS OF PROPULSION DURING VESSEL'S INBOUND TRANSIT INTO THE PORT. UPON ARRIVAL AT THE VESSEL, [name withheld] THAT THE OIL MIST DETECTOR ALARM ON THE MAIN ENGINE WAS TRIGGERED SHUT DOWN THE MAIN ENGINE. OIL MIST FILTER WAS REPLACED AND VESSEL WAS ABLE TO FINISH TRANSIT. PSCO CONDUCTED AN OPERATIONAL TEST OF THE ENGINE FOR TEN MINUTES AND OBSERVED NO ALARMS OR FAULTS. TEST WAS FOUND TO BE SATISFACTORY.
SOLAS (04). I/11(a)/60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 February 2024
Resolved 28 February 2024
Resolution: PSCO conducted operational test of main engine, all found satisfactory.
02114 - Bulkhead - Corrosion
Where "A" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc...arrangements shall be made to ensure that the fire resistance is not impaired. Rust/corrosion on the ceiling panels of the CO2 room and resulting corrosion on the nozzles underneath indicate potential water ingress.
74 SOLAS (1997)/ II-2 Reg 18.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2024
Resolved 8 March 2024
Resolution: Received class survey attesting to repairs
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 February 2024Resolved
07109 - Fixed fire extinguishing installation
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSC team found CO2 bottles with corrosion on nozzles.
74 SOLAS (2004)/ I Reg 11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2024
Resolved 8 March 2024
Resolution: Received class survey attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 August 2021Resolved
THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. ELECTRICAL OUTLET IN LAUNDRY ROOM WAS MODIFIED TO DRAW POWER FROM THE OVERHEAD LIGHT FIXTURE.
74 SOLAS (04) II-1/40.1.3
50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 14 August 2021
Resolution: SEC HG recieved technician report that oriiginal outlet power was restored and connection from the light fixture was removed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 10 March 2021Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL EXPERIENCED LOSS OF STEERING WHILE TRANSITING FROM PROGRESO, MEXICO TO PANAMA CITY, FLORIDA. PROVIDE CLASS REPORT ONCE REPAIRS ARE COMPLETE. PSCO WILL VERIFY SATISFACTORY STEERING OPERATIONAL TESTS UPON RECEIPT AND REVIEW OF CLASS REPORT.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 10 March 2021
Resolved 17 March 2021
Resolution: Steering system repaired with repairs confirmed by class surveyor. USCG witnessed satisfactory of test of steering system.
The master, owner, operator, agent, or person in charge of a vessel subject to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC) by electronic ballast water report format using methods specified at NBIC's Web site at http://invasions.si.edu/nbic/submit.html. The ballast water report will include the information listed in paragraph (c) of this section and must be submitted as follows: For any vessel that is equipped with ballast water tanks and bound for ports or places in the United States and not addressed in paragraphs (b)(1) and (2) of this section: Submit the ballast water report no later than 6 hours after arrival at the port or place of destination, or prior to departure from that port or place of destination, whichever is earlier.
Vessel failed to comply with reporting requirements during port call to Tampa, FL.
Action required: 10 - Deficiency Rectified
Due 18 November 2020
Resolved 18 November 2020
Resolution: Vessel submitted NBIC report on 06NOV20 after prior port call.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.