MAURY USCG vessel records
← All vessels

AAL GLADSTONE

AAL GLADSTONE is a freight ship. The Coast Guard has recorded 14 inspections since 2017, most recently in October 2025, along with 19 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 30 October 2025.

Built
Not recorded
Last inspected
30 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 October 2025
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9393541
1227464
Flag
CYPRUS
Maury page id
psix-1227464

Documentation record

Tonnage as PSIX records it19128 - Convention (Subpart B), Gross Ton
35111 - Displacement, Metric Ton
24984 - Dead Weight, Metric Ton
19128 - Regulatory (Subpart C or D), Gross Ton
9736 - Convention (Subpart B), Net Ton
9736 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

30 October 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8260741
22 September 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8239307
20 September 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8006548
10 September 2024 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7998676
7 September 2024 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7996398
6 September 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7997793
29 May 2023 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7699610
16 May 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7687265
13 November 2021 Deficiency Check · PSC B · MARPOL Annex VI Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7350099
18 August 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7290328
17 May 2021 Deficiency Check · PSC B · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7192523
9 May 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7192524
11 October 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6823093
12 January 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6065140

Deficiency record · 19

01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 10 September 2024 Resolved
The continuous synopsis record shall be issued by the administration to each ship that is entitled to fly its flag and it shall contain at east the following information: the name of all classification society(ies) with which the ship is classed. PSCO observed vessel's CSR lists Germanischer Lloyd as ship's classification society. 74 SOLAS (20) XI-1/5.3.11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2024
Resolved 25 September 2024
Resolution: received updated CSR
01 - Certificates & Documentation › 013 - Documents › Ship Energy Efficiency Management plan
Issued 7 September 2024 Resolved
After the end of calendar year 2023 and after the end of each following calendar year, each ship of 5,000 gross tonnage and above which falls into one or more of the categories in regulations 2.2.5, 2.2.7, 2.2.9, 2.2.11, 2.2.14 to 2.2.16, 2.2.22, and 2.2.26 to 2.2.29 of this Annex shall calculate the attained annual operational CII over a 12-month period from 1 January to 31 December for the preceding calendar year, using the data collected in accordance with regulation 27 of this Annex, taking into account the guidelines to be developed by the Organization. Vessel's SEEMP Statement of Compliance has no assigned CII rating. Vessel's documents (DOC) list "Ship Type" as General cargo ship, which falls into the regulation listed above (2.2.15). MARPOL VI/28.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 September 2024
Resolution: PSCO conducted MARPOL ANNEX 6 exam, determined vessel to designated as a Heavy Load Carrier based upon classification certificate.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2023 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of cargo ships, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and 9.6...PSCOs observed an opening in the A-Class bulkhead between the galley and duty mess unable to close due to electrical wiring passing through the opening. 74SOLAS(20)II-2/9.2.3.3.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 16 May 2023
Resolved 16 May 2023
Resolution: Electrical wiring was removed from passing through the opening.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 May 2023 Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions...Fire Control Plan does not show the opening on A-Class bulkhead between the galley and duty mess. 74SOLAS(20)II-2/15.2.4.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 29 May 2023
Resolution: Vessel submitted class report attesting to deficiency being rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 November 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. As referred in section 4.8.3.10.4, planned Preventative Maintenance in the vessel’s SMS the preventative maintenance must include the following items as a minimum safety: safety, damage-control, firefighting, lifesaving, and smoke, gas, and heat detection. As referenced in MacGreyor Instruction Manual section 5.005.49 E, every ten years replace all hydraulic hoses (crane). Vessel was unable to provide objective evidence that hydraulic hoses have been replaced per MacGregor Instruction Manual. As delineated in deficiencies 02 and 04, the company had failed to provide the necessary replacements in a timely manner. Vessel requisitioned replacement flame detectors 24Feb21 and window 01Mar2021. Internal audit is required prior to movement. Audit should focus on maintenance of equipment. 74 SOLAS (20) IX/ 3.1 ISM Code 10.1 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 November 2021
Resolution: Vessel conducted an internal Audit and issued two Non-comformities and provided Class DNV surevy for equipment repaired and a plan forward for the vessel drydock in February. Narrative contains audit specifics.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 November 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order. PSCO’s observed two fire detectors held in place above the #2 generator attached using shipping tape. 74 SOLAS (20) II-2/ 14.2.1.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2021
Resolution: Vessel provided Internal ISM audit which included comments and pictures of the fire detectors being fixed. Auditor also noted grating would need to get replaced at dry dock in February.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 November 2021 Resolved
All life-saving appliances and arrangements shall comply with applicable requirements of the code. PSCO’s observed pyrotechnics on the free fall life boat that did not meet the requirements of the LSA Code 74 SOLAS (20) III/34 LSA Code 4.4.8.13 LSA Code 4.4.8.14 LSA Code 4.4.8.15 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2021
Resolution: Vessel provided procurement delivery reciept and pictures for: 4ea-Pains Wessex Parachute Red Rocket,Mk8A 8ea-Pains Wessex Red Handflare,MK8 1ea-Pains Wessex Lifesmoke Mk9
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 November 2021 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. PSCO’s observed shattered window on bridge. Replacement window was requisitioned from company on 01Mar21. Company ordered replacement window on 18May21 ICLL 16.2 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2021
Resolution: Vessel provide Flag exemption letter stating they allow the vessel to perform voyages for the minimum necessary period not exceeding December 31, 2021 the latest, with one bridge window broken.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 May 2021 Resolved
THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEI REQUIRED PERFORMACE IF A FIRE OCCURS. STRUCTURAL FIRE PROTECTION, INSLUDING FIRE-RESISTING DIVISIONS, AND PROTECTION OF OPENINGS AND PENETRATIONS IN THESE DIVISIONS. THE PSCO OBSERVED 02 HOLES APPROX. 2 INCHES BY 2 INCHES IN BULKHEAD OF A CLASS BOUNDARY WATER CLOSET. 74 SOLAS(04) II-2/14.2.1.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 May 2021 Resolved
THE CONSTURCTION OF DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS, WITH THE MEANS OF SECURING THEM WHEN CLOSED, SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME EQUIVALENT TO THAT OF THE BULKHEADS IN WHICH THE DOORS ARE SITUATED. PSCO DISCOVERED ENGINE ROOM ENTRANCE DOOR DAMAGED. 74 SOLAS(04) II-2/9.4.1.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 May 2021 Resolved
THE CONSTURCTION OF DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS, WITH THE MEANS OF SECURING THEM WHEN CLOSED, SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME EQUIVALENT TO THAT OF THE BULKHEADS IN WHICH THE DOORS ARE SITUATED. PSCO FOUND 02 HOLES IN AC PIPE DOOR ON "B" DECK SITUATED ON AN "A" CLASS BOUNDARY. 74 SOLAS (04) II-2/9.4.1.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 November 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2021 Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. PSCO OBSERVED AREA OF FLOORING IN PRIMARY PASSAGE WAY ON MAIN DECK OUTISED LINEN CLOSET APPROX. 4FT BY 1FT SHOWING STRUCTURAL FAILURE. 74 SOLAS (04) II-1/3-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 14 November 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 May 2021 Resolved
CARGO, CARGO UNITS AND CARGO TRANSPORT UNITS CARRIED ON OR UNDER DECK SHALL BE SO LOADED, STOWED AND SECURED AS TO PREVENT AS FAR AS PRACTICABLE, THROUGHOUT THE VOYAGE, DAMAGE OR HAZARD TO THE SHIP AND THE PERSONS ON BOARD. PSCO FOUND SEVERE DETERIORATION AND WASTAGE OF CARGO SECURING GEAR BOX MEANT TO CONTAIN THE FOLLOWING: TWIST LOCKS, LASHING CHAINS, AND CHAIN TENSIONERS/BINDES; CREATING A SAFETY HAZARD FOR THE CREW LOCATED PORT SIDE, ALONG #1 CARGO HOLD. SOLAS 74 (14) VI/5.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 14 November 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 May 2021 Resolved
THE HOUSEKEEPING OF LIVING ACCOMODATION; DECK, ENGINE, AND CATERING DEPARTMENT STOREROOMS; PAINT IN STEERING GEAR ROOMS AND OTHER SUCH SPACES, TO ENSURE THE AVOIDANCE OF SITUATIONS PRESENTING A FIRE HAZARD. PSCO FOUND 02 UNAPPROVED WASHING MACHINES IN WATER CLOSET ON "E" DECK. WASHING MACHINES WERE RELOCATED BY CREW TO MAIN LAUNDRY ROOM. ILO 147 PG. 48 PWSA 46USC70002
Action required: 10 - Deficiency Rectified
Due 19 May 2021
Resolved 19 May 2021
Resolution: CREW REMOVED UNAPPROVED WASHING MACHINES FROM SPACE.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 May 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE FLAME SCREEN ON HIGH SULFUR FUEL OIL TANKS AND VENT SCREENS DISINTEGRATED ON TOUCH. 74 SOLAS (14) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 May 2021
Resolution: Vsl replaced flame screens on IFO Tank NO3 and NO1.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2021 Resolved
ALL ELECTRICAL APPARATUSES SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. GROUNDING WIRES ON 220V SWITCHES LOCATED THROUGHOUT CARGO DECK AREA WASTED OR MISSING. 74 SOLAS (04) II-1/45.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2021
Resolved 19 May 2021
Resolution: Vessel replaced all missing/wasted grounding wires.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 May 2021 Resolved
IN SPACES WHERE PENETRATION OF OIL PRODUCTS IS POSSIBLE, THE SURFACE OF INSULATION SHALL BE IMPERVIOUS TO OIL OR OIL VAPOURS. FORWARD MOST FUEL INJECTOR AND FUEL OIL FILTER RECENTLY HAD A MAJOR LEAK, SATURATING THE LAGGING AROUND AND UNDERNEATH FILTER. 74 SOLAS (04) II-2/4.4.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 May 2021
Resolution: Oil soaked lagging was replaced with fresh lagging
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 May 2021 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. ELECTRICAL CONNECTIONS ON ONE OIL PURIFIER AND FORWARD MOST MAIN DIESEL ENGINE OIL FILTER ARE COVERED/SOAKED IN OIL. 74 SOLAS (04) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2021
Resolved 19 May 2021
Resolution: Vessel cleaned all electrical connections in the oil purifier room.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 17 May 2021 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS WITH THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS ESTABLISHED BY THE COMPANY. THE COMPANY SHOULD ENSURE THAT APPROPRIATE CORRECTIVE ACTION IS TAKEN. PSCO NOTED CREW WAS UNABLE TO CONDUCT OR PERFORM PROPER MAINTENANCE DUE TO LACK OF COMPANY AID IN PROVIDING NECESSARY RESOURCES FOR MAINTENANCE. [name withheld] TO BE COMPLETED WITHIN 03 MONTHS. 74 SOLAS (14) IX/3 ISM CODE 10.2.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 August 2021
Resolved 23 November 2021
Resolution: Sector Houston- Galvston issued an ISM deficiency requesting an audit. See activity 7350099

Ownership record