Records from 2015 to 2022. Most recent: inspection, 25 October 2022.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 18 March 2013
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
25 October 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7583413
10 August 2021
Administrative Inspection · Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7272556
5 March 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7150958
27 July 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7017143
18 March 2019
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6644194
5 March 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6636670
5 June 2018
Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6434729
28 June 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6175504
28 February 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6096074
31 August 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5987614
3 May 2016
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5868140
26 August 2015
DAPI Audit · Annual Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5226649
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 October 2022
No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1). Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
46 CFR 176.500
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021
Resolved
Overdue for dry dock/ISE.
Action required: 10 - Deficiency Rectified
Due 5 March 2021
Resolved 10 August 2021
Resolution: Annual and Dry Dock completed on 10AUG2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 July 2020
Resolved
All vessels over 26 feet in length and have compartments with through-hulls are required to have a visual and audible high level alarm at the operating station. Bilge high level alarm in center compartment is not sounding. Repair or replace.
46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2020
Resolution: replaced panel at the operating station and functions properly now.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2020
Resolved
Alternator is not maintaining a charge for the batteries associated with the engine and causing them to die. Repair or replace alternator.
46 CFR 183320
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2020
Resolution: Alternator was replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2019
Resolved
A means to reset devices used to automatically shut down engines shall be installed. Automatic override switch is not working as intended. Make repairs. - 46 CFR 181.420(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2019
Resolution: Technician fixed electrical connection. System properly tested and operates to satisfaction of Marine Inspector
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2019
Resolved
Inspection of each hand portable fire extinguisher should be free of corrosion. BII fire extinguisher in forward compartment is wasting. Repair or replace with at a minimum 40BC. - 46CFR176.810(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 30 April 2019
Resolution: Fire Extinguisher Replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2019
Resolved
Complete audit of drug & alcohol program. - 33CFR151.16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2019
Resolution: Conducted satisfactory DAPI Audit
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 March 2019
Resolved
Complete man overboard - 46CFR185.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2019
Resolution: Conducted Satisfactory MOB Drill
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 March 2019
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is prohibited from operations until a drydock examination and an internal structural exam has been completed by a US Coast Guard Marine Inspector. 46 CFR 176.600 (c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2019
Resolution: Completed a satisfactory dry dock with CGMI.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 28 June 2017
Resolved
PROVIDE TECH REPORT PROVING PROPER OPERATION OF FIRE BOY SYSTEM. 46 CFR 181.410.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2017
Resolved 29 June 2017
Resolution: PROVIDED TECH REPORT PROVING PROPER OPERATION OF FIRE BOY SYSTEM.
Lifesaving › Hand Flares › Quantity
Issued 28 June 2017
Resolved
PROVIDE 6 RED FLARES AND 6 ORANGE FLARES. 46 CFR 185.614.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 29 June 2017
Resolution: PROVIDED 6 RED FLARES AND 6 ORANGE FLARES.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 August 2016
Resolved
Vessel must provide a copy of the valid COD. 46CFR67.7
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 8 September 2016
Resolution: Provided COD
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 31 August 2016
Resolved
Provide proper operation of fire suppression engine shutdown. 46CFR181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2016
Resolution: Verified tech servicing certificate and witnessed satisfactory test of engine sutdown/overide.
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 August 2016
Resolved
Provide proper operation of high bilge alarm. 46CFR182.530
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 8 September 2016
Resolution: Tested Bilge alrams
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 August 2016
Resolved
Provide new lifline and operational water light for ring buoy. 46CFR180.70
Action required: 705 - Other - as specified
Due 7 September 2016
Resolved 8 September 2016
Resolution: New lifline and battery for waterlight provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 August 2016
Resolved
Conduct underway MOB and fire drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2016
Resolution: Conducted drills
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 August 2015
Resolved
Provide EPIRB Log with monthly checks.
Due 23 September 2015
Resolved 11 November 2015
Resolution: EPIRB revomed from vesssel, Route changed to reflect removal.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 26 August 2015
Resolved
Provide EPIRB hydrostatic release (updated/valid)
Due 23 September 2015
Resolved 11 November 2015
Resolution: EPIRB revomed from vesssel, Route changed to reflect removal.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 August 2015
Resolved
Provide servicing report for Fire Boy system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2015
Resolution: Fire fighting equipment serviced.