MAURY USCG vessel records
← All vessels

O7 LAFITE

O7 LAFITE is a 2013 freight ship. The Coast Guard has recorded 34 inspections since 2016, most recently in March 2025, along with 8 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 23 March 2025.

Built
2013
Last inspected
23 March 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9534482
1227620
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1227620

Inspections, by type

…with no type recorded6
Years with a record 7 calendar years (2016–2025)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it6693 - Convention (Subpart B), Gross Ton
13015 - Displacement, Metric Ton
10018 - Dead Weight, Metric Ton
3441 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 34

23 March 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8095649
18 March 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8095617
29 October 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7585921
19 August 2022 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7538418
11 July 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7504124
6 June 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7463258
21 September 2020 PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7062288
17 February 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6910234
15 December 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6874090
4 September 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6803661
15 February 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6626334
10 February 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6623220
11 December 2018 Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6595952
6 December 2018 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6592833
11 November 2018 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6578785
24 September 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6547226
15 July 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6479418
11 January 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6335833
20 October 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6291720
15 March 2017 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6105094
11 January 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6069185
11 January 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6069233
10 December 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6055622
14 November 2016 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6040794
27 September 2016 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6010734
3 September 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5991110
31 August 2016 NPV Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5988533
13 July 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5939155
5 June 2016 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5897851
31 May 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5892951
6 May 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5870293
6 May 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5870302
6 May 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5870847
24 March 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5840042

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 August 2022 Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Vessel reported to PSC that one of two generator sets onboard was inoperable requiring repair. Vessel must rectify the issue by 18 September 2022 in keeping with Flag Dispensation issued regarding the same which permits the vessel to operate with only one generator set.
Action required: 705 - Other - as specified
Due 18 September 2022
Resolved 28 October 2022
Resolution: Vessel submitted satisfactory Class/Tech reports to Sector NOLA and were approved for rectification. Reports forwarded to Sector HOU/GAL for concurrence.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 6 June 2022 Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 parts per million. In considering the design of such equipment, the Administration shall have regard to the specification recommended by the Organization. The accuracy of the 15 ppm bilge alarms is to be checked by calibration and testing of the equipment conducted by a manufacturer or persons authorized by the manufacturer and should be done at intervals not exceeding five years after its commissioning, or within the term specified in the manufacturer's instructions. PSCO observed the last calibration date of the oil content meter was 23 May 2017. MARPOL (2017) Annex I/14.6 IMO Res MEPC 285(70)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 July 2022
Resolution: PSC NOLA recieved proper documentation from a technician satisfying the requirement.
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 January 2018 Resolved
1299: All pipes to which this regulation refers shall be of steel or other equivilent material to the satisfaction of the administration. A ship which undergoes repairs shall continue to comply with at least the requirements previously applicable to the ship. PSCO observed temporary patches on piping serving the inlet and outlet of main engine coolers and inlet and outlet of evaporator. IICL 66 Article 10 and I/22(5
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2018
Resolved 15 July 2018
Resolution: Received satisfactory class report attesting to permanent repairs to main engine coolers and evaporator.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 11 January 2018 Resolved
1541-Simple operating instructions with a block diagram showing changeover procedures for remote steering gear control systems and steering gear power units shall be permanently displayed on the navigation bridge. 74 SOLAS (14) V/26.3.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 11 January 2018
Resolution: A block diagram and simple change over procedures for remote steering were posted on the navigation bridge.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 31 August 2016 Resolved
The fire detection system located on the bridge is inoperable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 September 2016
Resolution: Received class report attesting to repairs of the fire detection circuit board.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 July 2016 Resolved
1020- Fire Alarm-Any required fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. The smoke detector in workshop area had a fitted cover over smoke detector preventing it's immediate operation. 74 SOLAS (2014 Cons.) II-2/7.2.2, FSS Code Ch. 8/2.5.1.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2016
Resolved 15 July 2016
Resolution: SEC HOU-GAL PSC received a class report from BV satisfying the requirement.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 13 July 2016 Resolved
Hydraulic power-operated steering gear shall be provided with a low level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on navigation bridge and in machinery space where they can be readily observed. Crew was unable to demonstrate operation of low level alarm. 74 SOLAS (2004) II-1/29.12.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2016
Resolved 15 July 2016
Resolution: SEC HOU-GAL PSC received a class report from BV satisfying the requirement.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 July 2016 Resolved
0820- Protection Machines/Parts- Machinery shall be installed and protected as to reduce danger to persons on board, due regard to moving parts. Ventilation fan located in stern engine room is exposed without a guard, rendering a hazard to the crew. 74 SOLAS (2004) II-1/26.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2016
Resolved 15 July 2016
Resolution: SEC HOU-GAL PSC received a class report from BV satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.