NAVE BELLATRIX

NAVE BELLATRIX is a 2013 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in June 2026, along with 9 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 1 June 2026.

Built
2013
Last inspected
1 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 June 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9459084
1227802
Flag
PANAMA
Maury page id
psix-1227802

Documentation record

Tonnage as PSIX records it39999 - Dead Weight, Metric Ton
50778 - Displacement, Metric Ton
30052 - Convention (Subpart B), Gross Ton
13255 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

1 June 2026 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8385329
18 June 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8162155
27 March 2025 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8100126
21 August 2024 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7985977
17 August 2024 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7983334
9 April 2024 COC-CHEM Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7887329
2 April 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7422835
24 March 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7418172
19 March 2021 COC-CHEM & TVE Annual
Type not classified · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7157126
18 February 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7142475
18 March 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6927560
4 February 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6902273
25 September 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6822689
5 June 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6699255
6 March 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6637635
1 February 2019 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6618777
16 January 2019 ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6610011
30 November 2018 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6586060
5 April 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6385576
20 March 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6374211
5 May 2017 COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6140063
11 August 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5967757

Deficiency record · 9

14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 9 April 2024 Resolved
SUBJECT TO THE PROVISIONS OF REGULATION 4 OF THIS ANNEX AND PARAGRAPHS 2, 3 AND 6 OF THIS REGULATION, ANY DISCHARGE INTO THE SEA OF OIL OR OILY MIXTURES FROM SHIPS SHALL BE PROHIBITED. DURING TEST OF INERT GAS GENERATOR, IT WAS OBSERVED BY THE PSCO, A VISIBLE SILVER SHEEN BE PRODUCED FROM VESSELS STBD AFT QUARTER. CREW SECURED IG SYSTEM AND THE PRODUCTION OF SHEEN CEASED. VESSEL SHALL NOT USE IG SYSTEM IN U.S. WATERS UNTIL THE CAUSE IS IDENTIFIED AND RECTIFIED. VESSEL SHALL NOT CONDUCT CARGO OPERATIONS IN U.S. PRIOR TO RECTIFICATION. MARPOL I/15.1 17A/C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2024
Resolution: Received satisfactory class report attesting to the correct operation of the IGG system.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 June 2019 Resolved
07102-Inert Gas System. The inert gas system refered in paragraph 5.5.3.1 shall be designed, constructed and tested in accordance with the FSS Code. Audible and visual alarms shall be provided bades on system design. The high O2 alarm was set at 6% O2, rather 5% as required by the SMS. Reccommended corective action be taken by company to ensure SMS compliance. 74SOLAS II-2/5.5.3.2 FSS 15.2.2.4.5.1 ISM7 action taken 10c.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Crew was able to change the O2 high level settings.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 June 2019 Resolved
07126-Oil accumulation in engine room. In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with following provisions 2.2.1. PSCO observed fuel leaks from all fuel pumps on auxiliary engine # 3, fuel leaks from fuel pump#2 and 6 on auxiliary engine #, and fuel leaks from fuel pumps #1,3,5,6 on main engine. 74SOLASII-2/4.2 action taken 60.a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 June 2019
Resolved 7 June 2019
Resolution: Received, reviewed and accepted class report from NKKstating the deficiency was rectified.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 20 March 2018 Resolved
1899 -Detailed instruction manuals shall be provide covering operations, safety, and maintenance requirements. Inert gas generator calibration instructions state to calibrate at 1.5% oxygen content. Calibration gas on hand has 2.0% oxygen. IGG calibration instructions state to use calibration gas at 0.5-1.0 BAR. Calibration gas was at 5.0 BAR during test. 74 SOLAS(04) II-2/4.5.5.1.1 FSS Code 15.2.2.5 10c
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 20 March 2018
Resolution: Rectified deficiency
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 20 March 2018 Resolved
1499 -Maintenance of condition after survey. The condition of the ship and its equipment shall be maintained to conform with the provisions of the regulation to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. Exhaust leak was discovered on the incinerator exhaust line. 74SOLAS(14) I/11(A) 50a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 5 April 2018
Resolution: Received Class report attesting to the repairs on the exhaust line to the incinerator, see attached document.
Engineering › Steam System (main) › Piping
Issued 20 March 2018 Resolved
1499 -Every steam pipe and every fitting connected there to through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. A steam leak was discovered in the boiler system. 74 SOLAS (14) II-1/33.1 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 5 April 2018
Resolution: Received Class report attesting to the repairs made to the boiler steam line, see attached document.
Engineering › Compressed Air System (control) › Fitting
Issued 20 March 2018 Resolved
1499 -Maintenance of condition after survey. The condition of the ship and its equipment shall be maintained to conform with the provisions of the regulation to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. The #1 camshaft airline was leaking at the fitting and had an inadequate temporary repair. 74SOLAS (14) I/11(A) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 20 March 2018
Resolution: Rectified deficiency
Engineering › Generator (propulsion/auxiliary-electric) › Heating Element Circuitry
Issued 20 March 2018 Resolved
1430 -Maintenance of condition after survey. The condition of the ship and its equipment shall be maintained to conform with the provisions of the regulation to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. #3 Generator water temperature inlet sensor was removed from the system. 74SOLAS(14) I/11(A) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 20 March 2018
Resolution: Rectified deficiency
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 March 2018 Resolved
1499 –Emergency switchboards shall be arranged so as to give easy access as may be needed to apparatus and equipment without danger to personnel. Batteries were improperly stored on the deck behind the emergency switchboard. 74SOLAS(14) II-1/45.2 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 20 March 2018
Resolution: Rectified deficiency

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.