This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it98451 - Convention (Subpart B), Gross Ton 30876 - Convention (Subpart B), Net Ton 81828 - Dead Weight, Metric Ton 112089 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 7
26 January 2022Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7386229
30 December 2021COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7368411
26 October 2020COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7078911
13 September 2019Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6804407
5 September 2019Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6804427
7 September 2018ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6533715
4 January 2017ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6063411
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 30 December 2021Resolved
The water spray system should cover all areas mentioned in 11.3.1 with uniformly distributed water spray. PSCO observed 05 nozzles on tank top 01 that were not operating.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 January 2022
Resolved 26 January 2022
Resolution: Satisfactory report from Recognized Organization of corrective action taken provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 December 2021Resolved
Lighting fittings should have pressurized fittings and enclosures or be of the flameproof type. PSCO observed 03 cracked light enclosures in the cargo machinery room and 01 in the cargo motor room.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 January 2022
Resolved 26 January 2022
Resolution: Satisfactory report from Recognized Organization of corrective action taken provided.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 30 December 2021Resolved
For spaces listed in 13.6.7, alarms should be activated for flammable products when the vapour concentrations reach 30% of the lower flammable limit. PSCO observed the fixed gas sampling system was reading the lower flammable limit incorrectly beyond the allowance of the span gas, therefor incorrectly activating the 30% LEL alarm.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 January 2022
Resolved 26 January 2022
Resolution: Satisfactory report of corrective action from Recognized Organization provided.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 September 2018Resolved
1138 - A master gas fuel valve that can be closed from within the machinery space should be provided within the cargo area. The vessel does not have any valves designated as the master gas valve.
SOLAS 74 (2014 Cons.) VII/13.1
IGC Code 16.3.7
50a/c
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2018
Resolved 7 September 2018
Resolution: The MGV's have been identified as listed on the ICOF and accepted as anequivalent to the IGC Code 16.3.7.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.