HAI JIN

HAI JIN is a 2013 freight ship. The Coast Guard has recorded 16 inspections since 2016, most recently in April 2024, along with 22 deficiencies and 6 operational controls.

Records from 2016 to 2024. Most recent: inspection, 15 April 2024.

Built
2013
Last inspected
15 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 April 2024
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9617674
9V7102
1228173
Flag
SINGAPORE
Maury page id
psix-1228173

Documentation record

Tonnage as PSIX records it58018 - Dead Weight, Metric Ton
68970 - Displacement, Metric Ton
32846 - Convention (Subpart B), Gross Ton
19582 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

15 April 2024 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7886678
3 October 2022 PSC B · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7569790
13 September 2022 PSC B · Appeal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7556150
1 September 2022 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7548531
23 February 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7139907
4 October 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7071153
10 July 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6735656
9 July 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6743903
10 January 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6608860
25 December 2018 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6602541
24 December 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6602294
17 April 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6125946
17 April 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6126103
16 April 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6126448
26 June 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5919008
13 June 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination · COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5900474

Deficiency record · 22

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 3 October 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO observed active fuel leak from the lifeboat. Upon review of the SMS and maintenance records, PSCO observed testing has been completed, however, proper testing/maintenance procedures were not followed and did not capture the active fuel leak. Recommend audit. 74 SOLAS (20) IX/3.1 ISM Code A 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 15 April 2024
Resolution: PSCO observed that the fuel line had been repaired in the Lifeboat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2022 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed an active fuel leak of the lifeboat main engine. Due to this, approx. 2 gallons of fuel were in the bilge. 74 SOLAS (20) II-2/4.1
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2022
Resolved 6 October 2022
Resolution: Class submitted report attesting to the satisfactory repair of the lifeboat engine.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 October 2022 Resolved
All life saving appliances shall be in working order and ready for immediate use. PSCO observed rescue boat engine not running without the choke fully engaged. 74 SOLAS (20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2022
Resolved 6 October 2022
Resolution: Class submitted report attesting to the satisfactory repair of the rescue boat engine.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 September 2022 Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING CONDITION. PSCO OBSERVED THE OUTBOARD MOTOR FOR THE RESCUE BOAT HAD AN INOPERABLE COOLING SYSTEM. 74 SOLAS (a.) 2020 CONS. III/20.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 September 2022
Resolved 17 September 2022
Resolution: The attending surveyor verified rescue boat engine as inoperable due to faulty water pump impeller. Repairs were completed & engine tested to the satisfaction of the attending surveyor. Deficiency considered rectified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 September 2022 Resolved
IN A SHIP IN WHICH OIL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED EXCESSIVE FUEL OIL LEAKS ON THE FOLLOWING EQUIPMENT PRESENTING A SERIOUS FIRE RISK ONBOARD: MAIN ENGINE #3 AND #4 CYLINDERS, #2 AND #3 AUXILIARY ENGINE FUEL SYSTEMS. IN ADDITION, NUMEROUS CONTAINERS OF OIL AND OTHER COMBUSTIBLE OIL LIKE PRODUCTS ARE STORED IN THE STEERING GEAR ROOM PRESENTING A SERIOUS FIRE HAZARD. 74 SOLAS (a.) 2020 CONS. II-2/4.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 September 2022
Resolved 17 September 2022
Resolution: The attending surveyor has verified that the vessel's main engine leaks were cleaned and found in order at the time of the inspection. In addition, the auxiliary engines were overhauled; See narrative and class report in documents
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 13 September 2022 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. DUE TO OBJECTIVE EVIDENCE IN DEFICIENCIES ISSED ON 13SEP22, THE VESSEL IS NOT IN SUBSTANTIAL COMPLIANCE WITH THE RELEVANT CONVENTIONS CALLING INTO QUESTION THE ADEQUACY AND IMPLEMENTATION OF THE VESSEL'S SMS UNDER THE ISM CODE, AN ADDITIONAL AUDIT, BY THE CERTIFICATE ISSUING AUTHORITY, IS REQUIRED PRIOR TO THE VESSEL'S RELEASE FROM DETENTION. 74 SOLAS (a.) 2020 CONS. IX/3.1 ISM CODE 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 September 2022
Resolved 17 September 2022
Resolution: Class NKK provided countermeasures taken by the vessel's gear to remedy deficincies & set additional audit date deadline for 15December2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 September 2022 Resolved
THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF OTHER FLAMMABLE OILS EMPLOYED UNDER PRESSURE IN POWER TRANSMISSION SYSTEMS, CONTROL AND ACTIVATING SYSTEMS AND HEATING SYSTEMS SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED EXCESSIVE HYDRUALIC OIL LEAKS ON THE HYDRAULIC STEERING SYSTEM PRESENTING A SERIOUS SAFETY AND FIRE RISK. 74 SOLAS (a.) CONS. II-2/4.2.4
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 September 2022
Resolved 17 September 2022
Resolution: The attending surveyor has verified that the Steering gear leaks were cleaned and at the time of the inspections found in order. In addition, the Expansion tank welding seams repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 September 2022 Resolved
THE ELECTRICAL POWER AVAILABLE SHALL BE SUFFICIENT TO SUPPLY ALL THOSE SERVICES THAT ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY. PSCO OBSERVED FUEL STORAGE TANK AT AN INSUFFICIENT FUEL LEVEL TO SUPPLY ALL SERVICES LISTED THAT ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY. 74 SOLAS (a.) 2020 CONS. II-1/43.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 13 September 2022
Resolved 17 September 2022
Resolution: The attending surveyor has verified that the Fuel oil tank refilled and found in order.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 September 2022 Resolved
The purpose of this regulations is to prevent the ignition of combustible materials or flammable liquids. For this purpose. the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO's observed excessive oil accumulation and leaks throughout the engine room including an active leak identified on the Fuel Oil Service Tank in the purifier space, a pool of oily water spanning the breadth of the forward engine room bilge, an approximately 3-by-5 foot patch of oil adhered to the purifier space overhead including piping and wiring, oil saturation beneath all 3 auxiliary generators, and various pools of oil located throughout the engine room and near machinery. 74 SOLAS (14) II-2/4.1.1 ACTION TAKEN: 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 September 2022
Resolution: PSCO's verified oil leaks have been rectified and accumulated oil has been cleaned
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 1 September 2022 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed deterioration of OWS piping between the OWS and 3-way valve resulting in complete separation of the pipe. 74 SOLAS (20) I/11(a) ACTION TAKEN: 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 September 2022
Resolution: PSC received Class Survey Statement (see attached document) attesting to replacement of the broken pipe section. PSCO's concurred with attestation following attendance on 08SEP2022 and functional test of the OWS and system piping.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 September 2022 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at the openings and penetrations. PSCO's observed the door for primary access to the engine room through the A-60 boundary was unlatchable. Crew repaired the latch, but the door was then unable to be opened as the latch handle is missing, and a hold is present where the handle belongs. 74 SOLAS (14) ii-2/9.1.3 ACTION TAKEN: 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2022
Resolution: PSC received Class Survey Report (see attached document) attesting to proper repair and function of A-60 door. PSCO's concur with recitification upon 08SEP2022 attendance following inspection and test of the A-60 door.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 1 September 2022 Resolved
Each incinerator on a ship constructed on or after 01 January 2000 shall meet the requirements contained in appendix IV to this Annex. Each incinerator subject to this paragraph shall be approved by the Administration taking into account the standards developed by the Organization. PSCO's observed substantial oil leakage from Incinerator Sludge Tank piping to the incinerator. Multiple flanges on these pipes were missing bolts and/or improperly seated. Refractory bricks are significantly deteriorated. 73/78 MARPOL VI/16.6.1 ACTION TAKEN: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2022
Resolution: PSCO verified that incinerator and components have been repaired
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 1 September 2022 Resolved
The recording device should also store data for at least eighteen months and should be able to display or print a protocol for official inspections as required. Vessel's crew was unable to present PSCO's with records of Oily Water Separator operation from the Oil Content Meter. 73/78 MARPOL I/14.6 MEPC.107(49) 4.2.9 ACTION CODE: 17ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 April 2024
Resolution: PSCO verified that new OCM has been installed and technician provided training to vessel's crew. Old OCM has been removed from vessel and technician will provide report attesting to corruption of OCM
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 September 2022 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation the requirements of this Code shall be treated as mandatory. In meeting these requirements the company should ensure that and non-conformity is repaired, with its possible cause if known; appropriate corrective action is taken; and records of these activities are maintained. (10.2) Vessel's SMS document MPM 9.5 paragraph 2 states (when a non-conformity is reported it should immediately be evaluated for the need to implement immediate corrective actions including follow up actions to prevent its recurrence.) Further, vessels SMS MPM section 10 outlines the maintenance procedures and required inspection intervals to be implemented. Referencing deficiencies 2, 3, 4, 5, and 6 objective evidence attests that the non-conformities were identified, not reported and immediate action was not taken to rectify all non-conformities. An external audit it required to be carried out with a focus on maintenance procedures and inspection intervals. Specifically for all equipment and appliances in the engine room, and firefighting appliance and the integrity of all fire boundaries. 74 SOLAS (14) IX/3.1 ISM Code 10.2.2 ISM Code 10.2.3 ISM Code 10.2.4
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 September 2022
Resolution: PSCO verified external audit was carried out to the satisfaction of the Coast Guard
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 February 2021 Resolved
Maintenance, testing and inspection shall be carried out based on the guidelines developed by the Organization (MSC.1/Circ.1432) and having due regard to ensuring the reliability of fire-fighting systems and appliances. Ship’s crew have not been testing flame detectors as a part of their fire systems maintenance since 29AUG2020, due to the fact that approved flame test lamp has not been provided onboard. PSCO unable to satisfactorily test flame detectors onboard. SOLAS 74 (2014 Cons.) II-2/14.2.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2021
Resolution: Satisfactory class report
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 February 2021 Resolved
Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. Vessel has not been provided with approved flame test lamp since 29AUG2020. Crew unable to satisfactorily test flame detectors onboard in accordance with their fire systems maintenance manual. SOLAS 74 (2014 Cons.) II-2/7.2.3 – FSS 9.2.5.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2021
Resolution: Satisfactory class report
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 23 February 2021 Resolved
Within 12 hours before departure, the ship’s steering gear shall be checked and tested by the ship’s crew. The test procedure shall include the rudder angle indicators in relation to the actual position of the rudder. Rudder angle indicator on starboard bridge-wing is reading an error of approximately 4-5 degrees. SOLAS 74 (2014 Cons.) V/26.1.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2021
Resolution: Satisfactory class report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 February 2021 Resolved
The Company should ensure that corrective action is taken, as appropriate. Crew has made two separate requisition orders for the approved fire test lamp since 29AUG2020 in order for them to appropriately test their flame detectors as per their fire systems maintenance plan. Crew has not been provided necessary equipment since 29AUG2020. SOLAS 74 (2014 Cons.) IX/3 – ISM 10.2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2021
Resolved 27 February 2021
Resolution: Satisfactory class report
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 17 April 2017 Resolved
ME had a loss of propulsion when it failed to respond to astern commands.
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 17 April 2017
Resolution: Rcvd survey report from DNV-GL surveyor.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 15 June 2016 Resolved
1420 - Cleanlines of engine room - means shall be provided to control leaks of flammable liquids. PSCO observed excessive engine oil pooled on top of main engine. 74 SOLAS 14 II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Engineering crew repaired fuel injector gasket and cleaned up excess fuel oil from top of engine.
Engineering › Steering Gear System › Piping
Issued 15 June 2016 Resolved
1499 - Other (prop. & aux. machinery) - Means shall be provided to control leaks of flammable liquids. PSCO observed hydraulic fluid leak from hydraulic fluid storage tank in steering gear room. 74 SOLAS 14 II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Engineering crew replaced seals on fixed piping coming from hydraulic fluid storage tank and cleaned up excess hydraulic fluid.
Fire Fighting › International Shore Connection › Washers
Issued 15 June 2016 Resolved
0799 - other (fire-fighting equipment) - International shore connections are required to have 08 washers. PSCO observed both international shore connections without adquate amount of washers. 74 SOLAS 14 II-2/10.2.1.7.1 / FSS CODE CH 2.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Deck crew replaced the washers for the international shore connections.