← All vessels
HAI SOON 61
HAI SOON 61 is a 2002 tank ship. The Coast Guard has recorded 23 inspections since 2017, most recently in December 2023, along with 53 deficiencies and 5 operational controls.
Records from 2017 to 2023. Most recent: operational control imposed, 29 December 2023.
- Built
- 2002
- Last inspected
- 20 December 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 53 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9276901 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
E5U3321
1228220
Flag
COOK ISLANDS
—
Maury page id
psix-1228220
Inspections, by type
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6564 - Dead Weight, Ton
9066 - Displacement, Ton
2085 - Convention (Subpart B), Net Ton
4251 - Convention (Subpart B), Gross Ton
9066 - Displacement, Ton
2085 - Convention (Subpart B), Net Ton
4251 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
20 December 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7841884
6 September 2023
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7776109
3 July 2023
PSC B · Deficiency Check · Appeal
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7721219
26 April 2023
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7676465
26 April 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7679883
7 February 2023
PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7632803
17 March 2022
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7413646
25 February 2022
PSC B · Deficiency Check · COC-TVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7397016
15 December 2021
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7368605
7 October 2021
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7319950
28 July 2021
Deficiency Check · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7256429
18 February 2021
PSC B · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7140138
28 December 2020
Ballast Water Examination · Deficiency Check · PSC B · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7116472
22 June 2020
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6978692
28 January 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6899905
24 January 2020
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6895806
21 January 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6893549
22 November 2019
Ballast Water Examination · ISPS II Exam · COC-TVE Annual · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6861058
2 April 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6654736
22 January 2019
PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6611436
7 December 2018
Ballast Water Examination · Deficiency Check · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6592036
18 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6543350
1 November 2017
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6298630
Deficiency record · 53
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 3 July 2023
Resolved
The company and ship shall comply with the requirements of the ISM Code. Objective evidence discovered in an expanded ISM examination revealed that the vessel’s implementation of its SMS failed to fully meet the requirements of the ISM Code. Specifically, the vessel was not maintained in conformity with the provisions of the relevant rules and regulations. This is made particularly evident by deficiency #02, as "2023" in the expiration date was obscured by an added label saying "2024," and deficiency #07, as the master had already signed the bottom of the page to attest that those equipment checks were done for the month of June. Deficiencies #03, #06, and #10 also show issues with vessel maintenance. Additionally, safe practices in ship operation and a safe working environment were not provided for. This is made particularly evident by deficiency #04, as following the operating instructions for the engine room fixed CO2 system would not have resulted in a discharge of the bottles, and deficiency #06, as attempts at temporary repairs were made, but using non-fire-resistant material. Deficiencies #02, #03, and #09 also show that a safe working environment was not being provided. An external audit is required.
74 SOLAS 20 IX/3.1
ISM Code 10.1
ISM Code 1.2.2.1
30ac
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 July 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. If a hydrostatic release unit is used in the float-free arrangements, it shall, if disposable, in lieu of the requirement in paragraph 4.1.6.3.6 be marked with a means of determining its date of expiry. Both liferafts had hydrostatic release units that expired in January 2023.
74 SOLAS 20 III/20.2
74 SOLAS 20 III/34
LSA 2017 4.1.6.3.8
17ac
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 July 2023
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and weathertight when closed. The means for securing these doors weathertight shall consist of gaskets and clamping devices or other equivalent means and shall be permanently attached to the bulkhead or to the doors themselves, and the doors shall be so arranged that they can be operated from both sides of the bulkhead.
ICLL 2021 12.1
17ac
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 3 July 2023
Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. To assist in casualty investigations, cargo ships, when engaged on international voyages, shall be fitted with a VDR which may be a simplified voyage data recorder (S-VDR) as follows: in the case of cargo ships of 3,000 gross tonnage and upwards but less than 20,000 gross tonnage constructed before 1 July 2002, at the first scheduled dry-docking after 1 July 2007 but not later than 1 July 2010. Vessel's S-VDR battery and acoustic beacon expired in June 2023.
74 SOLAS 20 V/16.1
74 SOLAS 20 V/20.2.2
17ac/ Changed to 50ac
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 3 July 2023
Resolved
Every tanker shall be provided with the means to enable the crew to gain safe access to the bow even in severe weather conditions. Such means of access shall be approved by the Administration based on the guidelines developed by the Organization. For tankers constructed on or after 1998, the access should be by means of either a walkway on the deck or a permanently constructed gangway of substantial strength at or above the level of the superstructure deck or the first tier of a deckhouse which should be fitted at each side throughout its length with a footstop and guard rails supported by stanchions. Such rails should consist of no less than 3 courses, the lowest being not more than 230 mm and the uppermost being at least 1 m above the gangway or walkway, and no intermediate opening should be more than 380 mm in height. Stanchions should be at intervals of not more than 1.5 m and be constructed of fire resistant and non-slip material. Vessel gangway has several corroded or broken stanchions and courses throughout the length of the gangway.
74 SOLAS 20 II-1 Regulation 3.3.2
17ac
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 July 2023
Resolved
Inspection of the life-saving appliances, including lifeboat equipment, shall be carried out monthly using the checklist required by regulation 36.1 to ensure that they are complete and in good order. A report of the inspection shall be entered in the log-book. Monthly checks for life jackets, immersion suits, line throwing appliances, communications, and the EPIRB were not documented for the month of June 2023.
74 SOLAS 20 III Regulation 20.7.2
16ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 July 2023
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The #2 general service pump is leaking a small but steady stream of water.
74 SOLAS 20 I/11(b)
10c
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 July 2023
Resolved
Lifebuoys complying with the requirements of paragraph 2.1.1 of the Code shall be so stowed as to be capable of being rapidly cast loose, and not permanently secured in any way. A lifebuoy in the forward starboard portion of the deck was stuck in its holder and not readily deployable.
74 SOLAS 20 III Regulation 7.1.1.2
10c
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 July 2023
Resolved
Lifeboat or rescue boat on-load release gear shall be maintained in accordance with instructions for on-board maintenance as required by regulation 36.
74 SOLAS 20 III Regulation 20.11.2.1
10c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2023
Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. While vessel was in transit, vessel lost astern propulsion due to a blocked air control valve as a result of trapped moisture.
74 SOLAS (04) II-1/28.1
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 7 February 2023
Resolved
All lifesaving appliances and arrangement shall comply with the applicable requirements of the code. The normal equipment of every lifeboat shall consist of: Six hand flares. 02 of 06 hand flares in starboard lifeboat are expired. 74 SOLAS (04) III/34 LSA code 4.4.8.14
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 7 February 2023
Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the code. The normal equipment of every lifeboat shall consist of: A food ration totaling 10,000KJ for each person the lifeboat is permitted to accommodate. 01 ration not in airtight packing. 74 SOLAS (04) III/34 LSA code 4.4.8.12
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2023
Resolved
No less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights. PSCO discovered 01 lifebuoy light on port side to be extinguished. 74 SOLAS (04) III/7.1.3
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 25 February 2022
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high level alarm and a tank overfill alarm. If installed after July 23, 1990, the high-level alarm and tank overfill alarm equipped by paragraph (a) of this section must-
(1) Be independent of each other
(2) Activate an alarm in the event of high loss of power to the alarm system. High water alarm not able to be demonstrated independently on all tanks.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 25 February 2022
Resolved
Each ballast water management system (BWMS) manufactured under Coast Guard approval must have a nameplate which is securely fastened to the BWMS and plainly marked by the manufacturer with the information listed in paragraph (b) of this section. No observable placard on BWMS and crew unable to locate it.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 25 February 2022
Resolved
Fire control plans and booklets shall be kept up to date: any alterations thereto shall be recorded as soon as practicable. Fire control plans that are kept in weathertight enclosures were not updated.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 October 2021
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Exhaust leak on emergency fire pump.
74SOLAS(04)II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 October 2021
Resolved
Where "B" class divisions are penetrated for the passage of electric cables, pipes, trunks, ducts, etc. or for the fitting of ventilation terminals, lighting fixtures and similar devices, arrangements shall be made to ensure that the fire resistance is not impaired. Cable penetration outside of owner's cabin has unknown type of putty used for insulation. Require fire rating of putty to be determined.
74SOLAS(01)II-2/18.1.2
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 July 2021
Resolved
THE CONDITIONS OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DAMAGE TO THE SHIP OR PERSONS ONBOARD. MAIN FIRE PUMP "P/P" LEAKING EXCESSIVELY. NUMBEROUS WATER LEAKS OF UNSATISFACTORY SCOPE DISCOVERED THROUGHOUT ENGINE ROOM BILGE, TO INCLUDE FRESHWATER LINE UNDERNEATH SHAFT AND SEVERAL PIPES IVO OILY WATER SEPERATOR.
74 SOLAS(2014)I/II(a)
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 July 2021
Resolved
THE ARRANGEMENT OF SEA CONNECTIONS, FIRE PUMPS AND THEIR SOURCES OF POWER SHALL BE AS TO ENSURE THAT IN PASSENGER SHIPS OF LESS THAN 1,000 GROSS TONNAGE AND IN CARGO SHIPS, IF A FIRE IN ANY ONE COMPARTMENT COULD PUT ALL THE PUMPS OUT OF ACTION, THERE SHALL BE AN ALTERNATIVE MEANS CONSISTING OF AN EMERGENCY FIRE PUMP COMPLYING WITH THE PROVISIONS OF THE FIRE SAFETY SYSTEMS CODE WITH ITS SOURCE OF POWER AND SEA CONNECTION LOCATED OUTSIDE THE SPACE WHERE THE MAIN FIRE PUMPS OR THEIR SOURCES OF POWER ARE LOCATED. FIRE PUMP INOPERABLE. LARGE AMOUNTS OF OIL OBSERVED LEAKING FROM PUMP, AND VESSEL UNABLE TO DEMONSTRATE FIRE HOSE TEST AT BRIDGE WING AND FOSCLE.
74 SOLAS (01) II-2/10.2.2.3.1.2
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 July 2021
Resolved
MECHANICAL EQUIPMENT PRESENTING HAZARDS TO PERSONNEL SHALL HAVE INSTALLATIONS OF BUILT-IN GUARDS FOR MOVING PARTS. THE EMERGENCY FIRE PUMP BELT CHAIN IS NOT COVERED AND PRESENTS A HAZARD TO THE CREW.
PWSA 46 USC 70002
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 July 2021
Resolved
THE PURPOSE OF THIS REGULATION IS TO LIMIT THE FIRE GROWTH POTENTIAL IN EVERY SPACE OF THE SHIP. FOR THIS PURPOSE , THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: THEN USE OF COMBUSTIBLE MATERIALS SHALL BE RESTRICTED. PLASTIC GARBAGE CAN FOUND IN GALLEY. EXCESS GREASE FOUND IN GALLEY HOOD.
74SOLAS(04)11-2/5.1.3
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2021
Resolved
EACH LIFE BOUY SHALL BE MARKED IN BLOCK CAPITALS OF THE ROMAN ALPHABET WITH THE NAME AND PORT OF REGISTERY OF THE SHIP ON WHICH IT IS CARRIED. 2 LIFEBUOYS WITH ILLEGIBLE WRITING AND DISCENTEGRATED SOLAS TAPE.
74 SOLAS (14) III/7.1.4
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 February 2021
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. 04 doors in Galley Class A Boundary fitted with hold-back hooks.
74SOLAS(04)II-2/9.4.2.2
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 28 December 2020
Resolved
Suitable portable instruments for measuring oxygen and flammable vapour concentrations shall be provided. Portable instruments unable to calibrate to span gas specifications.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 December 2020
Resolved
The high level alarm must be identified with the legend "High Level Alarm" in black letters. High level alarm signage are marked in red letters.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 December 2020
Resolved
The overfill alarm must be identified with the legend "TANK OVERFILL ALARM" in black letters. Tank overfill alarm are marked in red letters.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 December 2020
Resolved
The design of all engine exhaust pipes, air ducts and other openings shall be such that water is excluded from the engine when the lifeboat capsizes and re-rights. Exhaust on port and starboard lifeboats was found seized in the open position.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 December 2020
Resolved
Structural fire protection systems, including fire resisting divisions shall be kept in good working order so as to ensure their required performance if a fire occurs. Self-closing A-class fire doors on the main ladder well boat deck and bridge decks failed to fully self close and operate as intended.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 June 2020
Resolved
The design of all engine exhaust pipes, air ducts and other openings shall be such that water is excluded from the engine when the lifeboat capsizes and re-rights. Exhaust cover on port side lifeboat was found seized in the closed position. 74SOLAS(14CONS) III/31.1.1.1- LSA Code 4.6.3.4
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 November 2019
Resolved
Fire protction systems and fire fighting systems and appliances shall be maintained ready for use. The emergency fire pump is inoperable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 November 2019
Resolved
Machinery spaces of category A shall be adequately ventilated so as to ensure that when machinery or boilers therein are operating at full power in all weather conditions including heavy weather, an adequate supply of air is maintained to the spaces for the safety and comfort of personnel and the operation of the machinery. Portable fans are being used to assist in cooling the #2 generator, #3 generator, and main engine equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 November 2019
Resolved
The design of all engine exhaust pipes, air ducts and other openings shall be such that water is excluded from the engine when the lifeboat capsizes and re-rights. On the port side lifeboat the exhaust cap blew off once the lifeboat engine started.
11 - Life Saving Appliances › N/A - No Subsystem › Thermal Protective Aids
Issued 22 November 2019
Resolved
Before the ship leaves port and at all times during the voyage all life saving appliances shall be in working order and ready for immediate use. Vessel's port lifeboat was found with a hydraulic leak on the steering gear system.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 22 November 2019
Resolved
Every company should develop, implement and maintain a safety management system (SMS) which includes the following functional requirements: instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and flag state legislation. Vessel did not have testing procedures or records of testing cargo tank pressure sensors and associated alarms for proper operation.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 November 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The bottom of the sewage treatment plant has a leak and has corroded the surrounding metal.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2019
Resolved
Each separate circuit shall be protected against short circuit and against overload. In the engine room the following circuit breakers had tape on them which would prevent the circuit breaker from moving into the off position. NO.1 Transformer, Oil Discharge Monitoring System Converting Unit, and Hyd. Oil Pump Unit Fwd. Mooring Winch.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 22 November 2019
Resolved
Vessel must have the maneuvering information displayed on a fact sheet in the wheelhouse required by 33 CFR 164.35(g)(7). Vessel is missing the required warning statement.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo ship safety equipment (including exemption)
Issued 28 January 2019
Resolved
OIL TANKERS SHALL CARRY FIRE-PROTECTED LIFEBOATS COMPLYING WITH THE REQUIREMENTS OF SECTION 4.9 OF THE CODE. THE EXHAUST PIPE SHALL BE SO ARRANGED AS TO PREVENT WATER FROM ENTERING THE ENGINE IN NORMAL OPERATION. EXHAUST FLAP MISSING ON PORT LIFEBOAT.
74 SOLAS (14) III/ 31.1.1.7
LSA CODE 4.4.6.6
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 22 January 2019
Resolved
FIRE CONTROL PLANS AND BOOKLETS SHALL BE KEPT UP TO DATE, ANY ALTERATIONS BEING RECORDED THERON AS SOON AS PRACTICAL. AFT REEFER CHAMBER IN STEERING SPACE IS BEING USED AS A GENERAL STORAGE LOCKER.
74 SOLAS (01) II-2/ 20.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2019
Resolved
TO ENSURE SAFE AN DEFFECTIVE OPERATION OF THE AMS EQUIPMENT, THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF A VESSEL MUST ENSURE THE AMS IS MAINTAINED AND OPERATED IN CONFORMITY WITH SYSTEM SPECIFICATIONS. SHIPS CREW BYPASSED FILTER STAGE OF BALLAST WATER TREATEMNT SYSTEM DURING BALLASTING OPERATIONS OF TANKS 5,6,7 ON 03JAN19 WHEN THE AMS SYSTEM SPECIFICATION STATES DURING BALLAST OPERATIONS THE BALLAST WATER WILL FIRST BE FILTERED THROUGH 40 MICRON FILTER.
33 CFR 151.2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 7 December 2018
Resolved
EACH SURVIVAL CRAFT SHALL BE STOWED: FULLY EQUIPPED AS REQUIRED BY THE CODE. THE NORMAL EQUIPMENT OF EVERY LIFEBOAT SHALL CONSIST OF A FOOD RATION TOTALLING NOT LESS THAN 10,000 KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMODATE. VESSEL DID NOT HAVE FOOD RATIONS FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMODATE. PORT AND STARBOARD LIFEBOAT IS NOT EQUIPPED WITH ANY FOOD RATIONS. 74 SOLAS(14) III/13.1.4; LSA CODE 4.4.8.12. 30 ABC
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 December 2018
Resolved
EVERY OIL FUEL PIPE, WHICH IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM A STORAGE SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE CONCERNED IN THE EVENT OF A FIRE OCCURRING IN THE SPACE IN WHICH THE TANKS ARE SITUATED. VESSEL WAS FOUND FITTED WITH HOLD-BACK DEVICE ON THE QUICK CLOSING VALVE FROM THE MGO SERVICE TANK, WHICH SERVICES THE SHIP SERVICE GENERATORS AND BOILER. 74 SOLAS(01)II-2/15.2.5; 30 ABC
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 December 2018
Resolved
A CHEMICAL TANKER SHALL COMPLY WITH THE REQUIREMENT OF THE INTERNATIONAL BULK CHEMICAL CODE. SUITABLY MARKED DECONTAMINATION SHOWERS SHALL BE AVAILABLE ON DECK IN CONVENIENT LOCATIONS. THE SHOWERS SHALL BE OPERABLE IN ALL AMBIENT CONDITIONS. 02 EMERGENCY DECK SHOWERS ARE INOPERABLE.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 7 December 2018
Resolved
FIRE DOORS IN STAIRWAY ENCLOSURES SHALL BE SELF-CLOSING AND BE CAPABLE OF CLOSING AGAINST AN ANGLE OF INCLINATION OF UP TO 3.5 DEGREES OPPOSING CLOSURE. SELF-CLOSING DOOR LOCATED FOR MAIN STAIRWAY ON CAPTAIN'S DECK WAS FOUND INOPERABLE. 74 SOLAS(01) II-2/30.4.1; 10C.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 7 December 2018
Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN ACCORDANCE WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS, WHICH MAY BE ESTABLISHED BY THE COMPANY. THE CREW MEMBER ASSIGNED THE RESPONSIBILITY OF CHECKING LIFEBOAT PROVISIONS MARKED THE RELEVANT MONTHLY CHECKLIST FOR 02 MONTHS THAT ALL PROVISIONS WERE ACCOUNTED FOR. DURING THE EXAM, BOTH PORT AND STARBOARD LIFEBOATS HAD NO FOOD RATIONS ONBOARD. 74 SOLAS (14) IX/3.1; ISM CODE 10.1. 50 ABC
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 7 December 2018
Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. THE COMPANY SHOULD ESTABLISH PROCEDURES, PLANS, AND INSTRUCTIONS, INCLUDING CHECKLISTS AS APPROPRIATE, FOR KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF THE PERSONNEL, SHIP AND PROTECTION OF THE ENVIRONMENT. THE VESSELS SMS DOES NOT CONTAIN A CHECKLIST OR PROCEDURE FOR TESTING THE OILY WATER SEPARATOR OR OIL CONTENT METER. FURTHERMORE, THE CREW CLAIMED TO HAVE COMPLETED SMS PROCEDURE P0104, INTERNAL CLEANING OF THE OWS AS PER THE VESSEL'S SMS ON 10/21/18. THE CREW FAILED TO LOG THE MAINTENANECE IN THE VESSEL'S SMS AND THE SMS DOES NOT CONTAIN A CHECKLIST OR PROCEDURE FOR THE INTERNAL CLEANING OF THE OWS. 74 SOLAS (14) IX/3.1, ISM CODE 7, 50ABC
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 1 November 2017
Resolved
Alternatively, pressure sensors may be fitted in each tank protected by the arrangement required in paragraph 6.1.2, with a monitoring system in the ship's cargo control room. pressure sensors found inoperable in cargo tanks 1, 2/s, 3p, 4/p, 5s, 6p, and 7s 74SOLAS(02)II-2/11.6.3.2/ IBC CH. 8.3.3
Engineering › Bilge Water Management System › Not Operational
Issued 1 November 2017
Resolved
The bilge system serving the cargo pump-room shall be operable from outside the cargo pump room. Debris and rust scale found throughtout cargo pump room bilge. The bilge system sunction line is blocked by debris making the system inoperable unless cleared by hand locally 74 SOLAS(02)VII/10.1; IBC CH.3.3.3.5
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 1 November 2017
Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the code to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onboard or present anunreasonable threat to the environment. The sea suction valve for the cargo tank washing located in the pump room is leaking sea water into the pump room. The calve appears to be in poor material condition. 74SOLAS(02)VII/10.1; IBC CH.1.5.3.1
Deck/Cargo › Cargo Heating › General
Issued 1 November 2017
Resolved
When provided, any cargo heating or cooling system shall be constructed, fitted, and tested to the satisfaction of the Administration, Cargo heating system pressure relief valve stem found wasted in cargo pump room partial deck. 74SOLAS(02)VII/10.1; IBC CH. 7.1.1
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 1 November 2017
Resolved
Cargo pump rooms shall be so arranged as to ensure unrestricted passage at all times from any ladder platform and from the floor. The ladder from the poop deck leading into the pump room is wasted at the upper connection to the bulkhead 74SOLAS(02) VII/10.1; IBC Ch. 3.3.1.1
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 1 November 2017
Resolved
The operator of a vessel with a capacity of 250 barrels or more of oil shall provide transfer procedures that meet 33CFR 155.750. Transfer procedures for the vessel are missing an index, mooring procedures, shutoff locations, line diagram for VCS piping, operating procedures for VCS, closing transfer valves are closed at completion of operation , description and procedure for emptying containment system, specific communication procedures, procedures for reporting oil discharge into the sea. 33CFR155.720
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.