MAURY USCG vessel records Sign in
← All vessels

SILVER RAY

SILVER RAY is a 2013 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in August 2024, along with 1 deficiency and 2 operational controls.

Records from 2016 to 2024. Most recent: inspection, 8 August 2024.

Built
2013
Last inspected
8 August 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9493133 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1228315
Flag
LIBERIA
—
Maury page id
psix-1228315

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2016–2024)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6115 - Simplified, Net Ton
25056 - Displacement, Metric Ton
19801 - Dead Weight, Metric Ton
11733 - Convention (Subpart B), Gross Ton
6115 - Convention (Subpart B), Net Ton
11733 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

8 August 2024 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7977254
19 July 2024 COC-CHEM Renew · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7957202
12 July 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7956702
18 November 2022 COC-CHEM Renew · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7596864
31 July 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7521024
11 October 2021 COC-CHEM Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7330636
7 October 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7328447
28 November 2020 COC-CHEM & TVE Renew · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7102706
7 January 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6606384
27 October 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6569330
29 June 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459331
28 March 2016 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5841664

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 July 2024 Resolved
Where "A" class divisions are penetrated, such penetrations shall be suitably insulated by extension of the insulation at the same level of division. Wire insulation was missing in the foam room and in the nitrogen generator room. 74 Solas (20) II-2/9.3.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2024
Resolved 8 August 2024
Resolution: Attending surveyor confirmed the wire cable terminal insulation in the foam room and in the nitrogen generator room were sealed by new compound.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.