Inspection record

Last inspected 26 March 2026
…with no type recorded4
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 15 calendar years (2012–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

NOCALLSIGN
1228578
Flag
UNITED STATES
Maury page id
psix-1228578

Documentation record

Registered dimensions (L × B × D)75.7 ft × 34.7 ft × 5.5 ft
Registered tonnagegross 76 / net 76
ITC dimensions (L × B × D)75.7 ft × 34.7 ft × 5.5 ft
ITC tonnagegross 114 / net 65
BuilderBASIC MARINE INC · ESCANABA, MI, UNITED STATES · built 2013
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger Barge (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
114 - Convention (Subpart B), Gross Ton
76 - Regulatory (Subpart C or D), Net Ton
65 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 43 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 43

26 March 2026 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8332310
5 March 2026 Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8320335
30 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8148423
6 May 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8129777
28 March 2025 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8101139
24 April 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7900942
28 March 2024 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7886238
4 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7803243
3 April 2023 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7661943
3 April 2023 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7892976
24 March 2023 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7650985
13 October 2022 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7576464
4 March 2022 DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7404519
4 March 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7150904
11 July 2020 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7004893
11 July 2020 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7015000
5 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7038125
29 June 2019 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6733961
4 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6661006
29 March 2018 COI Inspection · DAPI Audit · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6370082
25 October 2017 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6297655
25 August 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6251436
19 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6152211
18 May 2017 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6149011
15 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6088801
16 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5912927
28 April 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5864999
7 April 2016 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5848975
7 July 2015 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5176426
4 June 2015 Deficiency Check · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5144231
4 August 2014 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4944560
24 July 2014 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4939017
24 July 2014 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5018883
19 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4893133
12 June 2014 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4891004
6 May 2014 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4851637
20 March 2014 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4820263
20 March 2014 Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4820338
13 December 2013 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4768982
16 August 2013 Examination of Repairs · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4711092
18 July 2013 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4657135
13 June 2013 Initial Certification · MARPOL Annex VI Survey · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4620445
31 August 2012 Drydock Exam · In-Service Inspection · Deadweight Survey · Deficiency Check · Initial Construction-Excluding Oversight · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4598307

Deficiency record · 22

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 March 2026 Resolved
EACH ACCOMEDATION AND SERVICE SPACE MUST BE FITTED WITH A SMOKE ACTUATED FIRE DETECTION SYSTEM. VESSEL FIRE DETECTION SYSTEM HAS A TROUBLE ALARM, REPAIR SYSTEM.
Action required: 10 - Deficiency Rectified
Resolved 26 March 2026
Resolution: Vessel repaired fire detection system, left watching properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 March 2026 Resolved
SPANNER WRENCHES MUST BE PROVIDED FOR EACH FIRE HYDRANT. FIRE STATION #2 IS MISSING SPANNER WRENCH, PROVIDE THE SAME.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 March 2026
Resolution: Vessel replaced spanner wrench at fire station #2.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 26 March 2026 Resolved
AT EACH INSPECTION THE VESSEL SHALL BE PREPARED TO CONDUCT TESTS AND HAVE READY FORE INSPECTION OF ITS FIRE PROTECTION EQUIPMENT INCLUDING TESTING OF VENTILATION SHUTDOWN/CLOSURES. PORT SIDE ENGINE SPACE VENTILATION CLOUSURES ARE MISSING SECURING HARDWARE. REPLACE THE SAME.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2026
Resolved 2 April 2026
Resolution: MI verified that hardware has been replaced and ventilation closures are working properly.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 26 March 2026 No resolution recorded
WINDOWS AT OPERATING STATION MUST PROVIDE ADEQUATE VIEW FOR SAFE NAVIGATION. TUG WINDSHIELD WINDOW HAS CRACK AND RISKS SPREADING. REPAIR OR REPLACE. 46 CFR 116.1030(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 March 2025 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. Penetrations in engine room fiddley space on the tug are missing fire stop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2025
Resolved 6 May 2025
Resolution: Received photos of fire stop in all penetrations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2024 Resolved
(d) Cable and wire for power and lighting circuits must: (2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable. Cables from generator to batteries was found to be welding cable. Replace with approved cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2024
Resolved 24 April 2024
Resolution: Received photographs showing approved UL marine cable installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Discovered heat tape on vessel that has been impropperly installed. Remove heat tape or install in accordance with manufacturers instructions.
Action required: 10 - Deficiency Rectified
Due 28 April 2024
Resolved 28 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2023 Resolved
Vessels tug (Riverview O.N. 1246342) is undergoing modifications to the hull, electrical system and propulsion system. Proper operation of the Tug is a stipulation on the COI in the Routes and Conditions. Prior to carrying passengers, prove proper operation of all systems on the tug and barge, and conduct sea trails on the vessels route to the safisfaction of an attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2024
Resolved 28 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Vessel has suffered an electrical fire in it's main switchboard cabinet. Suspected failed component is an automatic voltage regulator for the #2 genset that is installed inside of the switchboard cabinet. Vessel must identify cause of fire/component failure, make all repairs, and test all applicable systems prior to operating with passengers to the satisfaction of the local OCMI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 April 2023
Resolution: Vessel has made all repairs with authorized Marathon parts as per approved plans and conducted satisfactory testing of system.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 March 2022 Resolved
Fire detection system/panel has been annually serviced but has developed a "Trouble Alarm" present on panel. Vessel must make repairs and test to the satisfaction of local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2022
Resolved 8 March 2022
Resolution: Loose connection in fire detection panel was re-terminated, eliminating the trouble alarm for a horn strobe circuit, by CertaSite Company to the satisfaction of local OCMI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 March 2020 Resolved
Life ring line too short. Replace with line at least 60 ft.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2020
Resolved 5 March 2020
Resolution: Replaced line.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 March 2020 Resolved
Emergency light in egine room is not working. Replace or repair to full operation. 46 CFR 120.200(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2020
Resolved 5 April 2021
Resolution: Emergency light in engine room has been restored to proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 June 2019 Resolved
Vessel lost propulsion while getting underway with passengers. Must make repairs and test to Satisfaction of CG Inspector prior carrying passengers. 46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 29 June 2019
Resolution: Posted proper sequence for lighting off enginering plant. Tested, test SAT
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2018 Resolved
Prove proper operation of lower amber tow light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: Item corrected prior to completion of exam.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2018 Resolved
Remove cameras from front of port and starboard running lights.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: Crew relocated cameras to below plan of lights and provided photos.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 29 March 2018 Resolved
Renew Seafire bottle onboard tug RIVERVIEW. 825 issued under barge using 46 CFR 115.840
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: Once bottle was warmed to 70 degrees gauge moved to green. Accepted with condition bottle would be renewed. Owner ordered replacement.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 May 2017 Resolved
Child PFD storage was not labeled
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 25 August 2017
Resolution: Proper label stencilled on.
Operations/Management › Drills/Instruction › Fire
Issued 18 May 2017 Resolved
MOB/ FIRE and Senior deckhand mooring of vessel were all unsat
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 19 May 2017
Resolution: Drills completed satisfactory
Lifesaving › Lifebuoys › Serviceable
Issued 7 April 2016 Resolved
Replace all 3 Life Ring Buoy's with new 30 inch. 46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 28 April 2016
Resolution: New liferings verified by marine inspector.
Electrical › Electric Supply System (service) › Cable
Issued 4 June 2015 Resolved
Extension cords behind bar ar daisy chained together and needs to be removed.
Action required: 705 - Other - as specified
Due 5 June 2015
Resolved 5 June 2015
Resolution: Cords removed.
Communications › Visual Communication › Warning Sign (gangway)
Issued 4 June 2015 Resolved
Fire control plan required to be updated.
Action required: 705 - Other - as specified
Due 17 July 2015
Resolved 8 July 2015
Resolution: Plan updated.
Engineering › Steering Gear System › Motor
Issued 24 July 2014 Resolved
steering gear not operating properly
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2014
Resolution: Tested steering all sat.