MAURY USCG vessel records
← All vessels

ADRE

ADRE is a freight ship. The Coast Guard has recorded 6 inspections since 2017, most recently in May 2025, along with 7 deficiencies and 1 operational control.

Records from 2017 to 2025. Most recent: inspection, 4 May 2025.

Built
Not recorded
Last inspected
4 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 May 2025
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9575199
9V8641
1229162
Flag
LIBERIA
Maury page id
psix-1229162

Documentation record

Tonnage as PSIX records it35812 - Convention (Subpart B), Gross Ton
63301 - Dead Weight, Ton
21224 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

4 May 2025 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8123944
10 April 2025 Deficiency Check · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8100125
12 March 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7878046
10 July 2023 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7727145
16 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6776215
14 December 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6318719

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 April 2025 Resolved
74 SOLAS II-1/32.5 Amended Boilers shall be provided with means to supervise and control the quality of the feedwater. Suitable arrangements shall be provided to preclude, as far as practicable, the entry of oil or other contaminants which may adversely affect the boiler; vessel’s cascade tank has fuel oil intrusion. Tank must be free from petroleum products and prima facia evidence must be provided that waterside of boiler is free from petroleum products.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 April 2025
Resolution: Fuel Tank Steam lines were blanked off and cascade tank was cleaned. Inspected by Class, Flag and USCG. Objective evidence uploaded in documentation tab and notated in the narrative.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 April 2025 Resolved
74 SOLAS Amended II-2/10.5.6.2 Machinery spaces of category A above 500 m3 in volume shall, in addition to the fixed fire-extinguishing system required in paragraph 5.1.1, be protected by an approved type of fixed water-based or equivalent local application fire-extinguishing system; vessel’s hypermist system failed to operate in incinerator and purifier room when tested by PSCO and Flag State Inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 April 2025
Resolution: All valves were disassembled and cleaned and new PLC installed. Inspected by Class, Flag and USCG. Objective evidence uploaded in documentation tab and notated in the narrative.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 April 2025 Resolved
74 SOLAS Amended II-2/4.1 means shall be provided to control leaks of flammable liquids; several leaks on main engine, #2 Generator and fuel boost pump for main engine in purifier room.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 April 2025
Resolution: Engine room, Main Engin, Generator fuel Rack, and Purifier room was inspected by Class, Flag and USCG.Objective evidence uploaded in documentation tab and notated in the narrative.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 April 2025 Resolved
74 SOLAS Amended III/20.2 Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use; crew was unable to keep rescue boat running when directed by PSCO to start.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 15 April 2025
Resolution: Crew was able to fix rescue boat and run it in gear both forward and aft. Objective evidence uploaded in documentation tab and notated in the narrative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 April 2025 Resolved
74 SOLAS Amended II-1/26.7 Provision shall be made to facilitate cleaning, inspection and maintenance of auxiliary machinery; Engine room crew was unable to open incinerator door when directed by PSCO
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2025
Resolved 15 April 2025
Resolution: Incenerator was operated and tested. Objective evidence uploaded in documentation tab and notated in the narrative.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 10 July 2023 Resolved
74 SOLAS (14) II-2/2.1.1 THE MAIN INLET AND OUTLET OF ALL VENTILATION SYSTEMS SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE SPACED BEING VENTILATED. THE MEANS OF CLOSING SHALL BE EASILY ACCESSIBLE AS WELL AS PROMINENTLY AND PERMANENTLY MARKED AND SHALL INDICATE WHETHER THE SHUT-OFF IS OPEN OR CLOSED. PSCO OBSERVED 02 VENTILATION DAMPERS TO NOT BE CAPABLE OF BEING FULLY CLOSED FOR THE EMERGENCY GENERATOR ROOM VENTILATION SYSTEM.
Action required: 10 - Deficiency Rectified
Resolved 10 July 2023
Resolution: CORRECTED ON THE SPOT AFTER BRIEFING TO COMMAND
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 10 July 2023 Resolved
74 SOLAS (20) I/11(a) THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED REFRACTORY WITHIN INCINERATOR TO HAVE LARGE SECTIONS MISSING.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2024
Resolution: PSC NOLA received a class report from BV satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.