Inspection history · 6
27 December 2025
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8283696
7 September 2021
PSC B · Polar Code Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7306868
6 November 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6850523
5 March 2018
MARPOL Annex VI Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6366323
28 August 2017
Ballast Water Examination · NPV Safety Exam · Random ISPS/MTSA/PSC
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6253836
16 November 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6037081
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 December 2025
Resolved
The arrangements for the storage, distribution and utilization of oil used in lubrication systems shall be such as to ensure the safety of the ship and persons on board. PSC Inspector discovered a corner in the engine room soaked in oil that was use to clean oil filters. 74 SOLAS 2024 II-2/2.4.2.3.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2025
Resolution: Sector Columbia River received a class report from DNV attesting to cleaning of engine room and rectification.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 December 2025
Resolved
Insulating materials shall be non-combustible. PSC Inspector found two separate laggings soaked of oil in the engine room. 74 SOLAS 2024 II-2/5.3.1.1
Action required: 10 - Deficiency Rectified
Resolved 27 December 2025
Resolution: Vessel was able to replace oil soaked lagging on the spot to satisfaction of the PSCO.
Operations/Management › Pollution › General
Issued 5 March 2018
Resolved
2430 - While ships are operating within an emission control area (ECA), the sulfur content used on board ships shall not exceed 1%. On March 03, 2018, while in the ECA, at 1530 the vessel switched from LSMGO to HSFO. The vessel then proceeded to the port of Baltimore and did not switch back to LSMGO until 1910 on March 04, 2018. The ship utilized fuel oil that does not comply with the MARPOL Annex VI ECA sulfur limits. MARPOL Annex VI Reg. 14.4 10c
Condition: Placed in Improper Service
Due 5 March 2018
Resolved 5 March 2018
Resolution: Deficiency rectified while in the port of Baltimore.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 16 November 2016
Resolved
1499-Other Prop Auxiluary Machinery. Second source of energy shall be provided with three additional starts within 30 minutes. PSCO's identified that the Battery Bank #1 for the Emergency Generator was inoperable. 74 SOLAS (14) II-1/44.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2016
Resolved 26 November 2016
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. 2 new batteries were purchased and successfully tested.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 16 November 2016
Resolved
0899-Other Accident Prevention. Each transfer pipe must be annually tested at 1.5 times the MAWP. Vessel had records of testing from 2014 but nothing within the past 12 months. 33CFR156.170
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Due 16 November 2016
Resolved 29 November 2016
Resolution: Recieved NKK Class report and the deficiency has been rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 November 2016
Resolved
1740-Oil Discharge and monitoring equipment. Vessel was unable to recall operational history with any accuracy due to dates and times being modified both before and after operations. MARPOL 73/78 Annex I/11.1, MEPC 107 (49) 4.2.9
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 29 November 2016
Resolution: Recieved NKK Class report and the deficiency has been rectified.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 16 November 2016
Resolved
0715-Fire Detection. Testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensure the reliability of the fire systems and appliances. PSCO's noted tha the heat detector in the engineers workshop was badly damaged. It tested satisfactorly, however the reliability of the unit is in question.74 SOLAS(14) II-2/14.2.2.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 29 November 2016
Resolution: Recieved NKK Class report and the deficiency has been rectified.