Records from 1986 to 2026. Most recent: inspection, 20 March 2026.
Inspection history · 62
20 March 2026
Vessel Attendance · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8328093
19 August 2025
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8213399
7 April 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8103304
29 February 2024
Drydock Exam · Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7871639
23 January 2024
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7853570
17 April 2023
Administrative Inspection · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7670115
9 December 2021
Simplified Stability Test · Deficiency Check · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7365476
6 December 2021
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7364003
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110405
8 December 2020
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7107879
2 July 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6993270
26 March 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6642677
30 November 2018
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6590119
7 December 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6320826
8 November 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6306913
10 May 2016
Internal Structural Exam · Examination of Repairs · Drydock Exam · Simplified Stability Test · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5873472
27 May 2014
Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4870482
2 August 2011
Damage Survey · Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4103865
1 August 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4103893
17 December 2010
Deficiency Check · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3913265
23 November 2010
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3896579
18 November 2010
COI Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3889877
5 October 2010
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3860578
5 January 2010
DAPI Audit · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3656771
3 March 2009
Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3425205
3 March 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3157989
10 January 2008
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3127892
11 September 2007
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3055462
23 May 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2938039
23 May 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2938106
9 February 2007
Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2869533
5 December 2005
COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2546185
27 October 2005
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2523163
22 February 2005
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2297205
3 August 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2154354
19 June 2003
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1821268
20 May 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1797322
14 February 2003
Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1743882
22 August 2002
Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1665008
29 July 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1653653
13 March 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1060815
20 February 2001
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412230
9 December 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 807289
12 November 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434766
7 August 1997
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396768
1 August 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445104
30 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 882757
10 October 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367525
10 August 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1437002
8 September 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867242
14 July 1994
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370895
24 May 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 862849
8 July 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440723
11 February 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141445
21 January 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463032
13 August 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 958498
9 July 1991
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 936530
24 May 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 913469
18 January 1990
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 930278
1 December 1989
COI Inspection · Hull Examination · Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1222573
29 July 1986
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1310903
12 June 1986
COI Inspection · Credit Drydock
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 992057
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 April 2026
Resolved
Each life float must be fitted with a lifeline, pendants,two paddles, a painter, and a light. Marine inspector found incorrect and inoperable painter line.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2026
Resolved 8 April 2026
Resolution: Painter line replaced. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 April 2026
Resolved
The shutoff at the tank must be manually operable from outside the compartment. Marine Inspector found shut off valve was not in compliance with fire retardant materials and rubber hoses as reach rod lengths.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 April 2026
Resolved 9 April 2026
Resolution: Rubber hoses replaced with metal rod. Deficiency cleared.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 April 2026
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Marine Inspector found hydrostatic release expired June 2025.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2026
Resolved 8 April 2026
Resolution: Hydrostatic release replaced with expiration date April 2028. Deficiency cleared.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2026
Resolved
The Rules concerning shapes shall be complied with by day. Vessel did not have any day shapes onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 13 April 2026
Resolution: Dayshapes on board. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 April 2026
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Egress from berthing to pilot house was not marked properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 10 April 2026
Resolution: Egress marked appropriately. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 April 2026
Resolved
Each item of survival craft equipment must be of good quality. Marine Inspector found degrading reflective tape on life floats and paddles not secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 10 April 2026
Resolution: Reflective tape replaced and paddles secured. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2026
Resolved
Each ring life buoy on a vessel must be orange in color. Marine Inspector found ring life buoy color faded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 10 April 2026
Resolution: Life bouy ring replaced. Deficiency cleared.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 8 April 2026
Resolved
Radiotelephone required must be carried on board. Marine Inspector found Bridge-to-Bridge Certificate expired June 2025.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 8 April 2026
Resolution: Vessel rep sent proof of new documents. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2026
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers. Not all pages of vessel COI were posted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 10 April 2026
Resolution: All pages of COI posted and visible to passengers. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 8 April 2026
Resolved
A vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Observed cracked welds on the following locations. Steering room port exhaust bulkhead penetration, steering room stbd exhaust bulkhead penetration, and engine room stbd fixed ballast
structure support.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 10 April 2026
Resolution: cracked welds fixed to satisfaction of marine inspector. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2026
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Not all pages of vessel stability were posted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 10 April 2026
Resolution: All pages of Stability letter posted. Deficiency cleared.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 April 2026
Resolved
The owner, managing operator, or a qualified servicing facility must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 9 April 2026
Resolution: Monthly inspection tags added to extinguishers. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 April 2026
Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. Hydraulic lines servicing steering gear were not adequately supported.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2026
Resolved 9 April 2026
Resolution: Supports added to satisfaction of marine inspector. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 August 2025
Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. MSU Brownsville discovered vessel out of water with ongoing work with no notification to the Coast Guard. 46CFR2.01-15
Continue to work with Coast Guard for repair of crack in doubler near propeller.
Action required: 705 - Other - as specified
Resolved 20 August 2025
Resolution: MI received satisfactory evidence of repairs.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 April 2025
Resolved
Up-to-date charts and nautical publications of large enough scale to make safe navigation possible as appropriate for the intended voyage, must be carried onboard vessels. MI found no local charts for intended voyages.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2025
Resolved 21 April 2025
Resolution: POC sent proof of new charts on deck.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 April 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessels port exhaust pipe in the lazarette has a broken bracket. Repair prior to credit Drydock.
Action required: 705 - Other - as specified
Resolved 25 August 2025
Resolution: Vessel completed in repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 April 2025
Resolved
For each alternating current generator, a means for measuring frequency must also be provided. Vessels frequency meter is OOC.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2025
Resolved 21 April 2025
Resolution: POC sent proof of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2024
Resolved
Receptacle outlets of the type providing a grounded pole or a specific direct current polarity must be of a configuration that will not permit improper connection. MI found grounded outlet using portable ground detector in passenger area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 29 April 2024
Resolution: Recieved pictures of corrective actions. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date; (1) charts of large enough scale to make safe navigation possible. MI found Vessel charts are not up-to-date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 29 April 2024
Resolution: Recieved pictures of corrective actions. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 April 2024
Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part, must be approved by the Commandant. MI found deteriorated life rings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 29 April 2024
Resolution: Recieved pictures of corrective actions. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 April 2024
Resolved
Each item of lifesaving equipment carried on board a vessel but not required under this part, must be approved by the Commandant. Vessel had deteriorated life ring grab lines.
46 CFR 180.25(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 29 April 2024
Resolution: Recieved pictures of corrective actions. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 January 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Prior to the carriage of passengers the vessel shall complete a drydock
46 CFR 176.600(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2024
Resolution: Conducted Credit Dry Dock
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 April 2023
Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter: The strength of the float-free link & the strength of the painter must be determined by the combined capacity of the group of life floats. Vessel had incorrect float-free link capacity. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2023
Resolution: Added correct float free link
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 April 2023
Resolved
If the vessel carries more than one life float in a group with each group secured by a single painter: Each life float must be individually attached to the painter by a line meeting § 180.175(f)(3) (ii), (iii), and (iv) and long enough that each life float can float without contacting any other life-float in the group. Vessel had two life floats sitting on top of each other with no spacers to prevent adhesion. Repair to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2023
Resolution: Took out of series.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 April 2023
Resolved
Equipment specifications for life floats. The equipment required for lifefloats must meet the following specifications: Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Batteries for the waterlights were all expired. Repair to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2023
Resolution: Batteries on lights were replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2023
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The reach-rod attached to the fuel shutoff on the aft tank in the engine room was broken off and unable to operate the shutoff vale. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2023
Resolution: Repaired reachrod.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 April 2023
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Two clamps must be used on each end of the hose. Vessel only had one hose clamp on each side of flexible hoses for the bilge/fire pump. Repair to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Put on new hose clamps
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 20 April 2023
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel was unable to provide current records for chemical tests. Maintain records to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2023
Resolution: Part of a consoritum
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 April 2023
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection which provide strength and support equivalent to fixed rails may be used. Deck rails minimum height 36". Vessels aft deck rail insert bracket was broken. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: welded new bracket
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 April 2023
Resolved
The means used to attach the float-free link to the vessel must: If synthetic, be of a dark color or of a type certified to be resistant to deterioration from ultraviolet light. Vessel unable to verify if line was synthetic or natural. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Verified line is correct.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 April 2023
Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Vessel was not testing on a monthly basis and logging test. Conduct and log monthly testing to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Conducted monthly test
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2023
Resolved
At each inspection for certification all observed unsafe practices and other hazardous situations must be corrected and must be in satisfactory condition. A light on the port side aft of the engine was filled with a water and oil mixture. Repair to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
Resolution: Removed liquid from lights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2023
Resolved
All cable and wire must:Be installed with metal supports spaced not more than 24" apart, and in such a manner as to avoid chafing and other damage. Vessel had numerous areas in the spaces where wires were not supported with metal supports and more than 24" apart. Repair to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
Resolution: placed wires inside supports.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 20 April 2023
Resolved
Piping conveying vapor, gas, or liquid, the temperature of which exceeds 150 °F, must be suitably insulated. Vessel had missing insulation on the port engine exhaust. Repair to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
Resolution: Installed lagging around exhaust pipe
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 April 2023
Resolved
At each inspection for certification all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and must be in satisfactory condition. The port side engine exhaust mount has a cracked weld at deck access hatch coaming. Vessel drilled holes through fractured mount and bolted together. Permanently repair to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Welded cracked bracket
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 20 April 2023
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. Vessel did not have a garbage management plan. Develop a garbage management plan to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
Resolution: Developed a garbage plan.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 20 April 2023
Resolved
If an inlet or discharge pipe is inaccessible, the means for complying with paragraph (c) of this section must be a shut-off valve that is: Operable from the weather deck or any other accessible location above the bulkhead deck; and Labeled at the operating point for identity and direction of closing. The valve for vessel sewage discharge line is below deck and inaccessible. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Verified shutoff pipe was accesible.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 April 2023
Resolved
At each inspection for certification all observed unsafe practices and other hazardous situations must be corrected and must be in satisfactory condition. The permanent fixed ballast on starboard side has broken bracket straps. Repair to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2023
Resolution: Welded brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 April 2023
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: On each life float. The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float. This number must: Be the number of persons the device is equipped for; and Not be greater than the number of persons the device is approved for as shown on its nameplate. The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Vessel did not have vessels name and capacity marked on each life float and vessels name on each life float paddle.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2023
Resolution: Painted name of vessel on life floats.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 20 April 2023
Resolved
The vessel must have on board a valid certificate which is issued by the FCC to prove installation of radio transmitting equipment. Vessels radiotelephone certificate is expired. Obtain a current certificate for your vessel.
46 CFR 80.401
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2023
Resolution: issued a new radiotelephony certificate
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2023
Resolved
A vessel of more than 26' in length, but not more than 65', must carry a minimum of one life buoy of not less than 24" in diameter; and at least one ring life buoy must be fitted with a lifeline and must carry one floating waterlight. Vessel had two 20" diameter life buoys on board which are not allowed. The waterlight required by the regulation was attached to a 20" diameter life buoy. Remove all incorrect size life bouys and attach lifeline and waterlight to appropriate life buoy.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2023
Resolution: Verified correct size
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2023
Resolved
Each generator must have a nameplate attached to it containing the information required by Article 445 of NFPA 70, and for a generator derated in accordance with paragraph (b)(2) of this section. Nameplate on the generator was faded and not legible. Replace with legible name plate to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2023
Resolution: Issued new def
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel did not have required fire buckets. Obtain fire buckets to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 April 2023
Resolution: Found fire buckets
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 April 2023
Resolved
TO MAINTAIN A VALID CERTIFICATE OF INSPECTION, YOU MUST COMPLETE YOUR ANNUAL INSPECTION WITHIN THE PERIODS SPECIFIED IN § 176.500(b)(1) AND YOUR CERTIFICATE MUST BE ENDORSED. VESSEL DID NOT UNDERGO AN ANNUAL INSPECTION WITHIN THE 3 MONTHS BEFORE OR AFTER EACH ANNIVERSARY DATE. (LAST ANNIVERSARY DATE 10JAN2022) VESSEL MUST CONDUCT A INSPECTION FOR RENEWAL TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2023
Resolution: Conducted COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 April 2023
Resolved
Each generator must have a nameplate attached to it containing the information required by Article 445 of NFPA 70, and for a generator derated in accordance with paragraph (b)(2) of this section. Nameplate on the generator was faded and not legible. Replace with legible name plate to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 October 2023
Resolution: Installed on generator
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 December 2021
Resolved
Vessel missed it's required annual inspection (past the 90 day window)
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2022
Resolved 10 January 2022
Resolution: Vessel owner completed a COI renewal inspection
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 July 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2020
Resolved 2 July 2020
Resolution: FLARES WERE PURCHASED AND REPLACED
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2020
Resolved
ONE ADULT LIFE JACKET WAS MISSING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2020
Resolved 2 July 2020
Resolution: NEW LIFE JACKET WAS PURCHASED AND REPLACED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 July 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2020
Resolved 6 July 2020
Resolution: LIFE JACKET LIGHTS WERE PURCHASED AND REPLACED.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2020
Resolved
PORTABLE AND SEMI PORTABLE EXTINGUISHERS MUST BE INSPECTED AND MAINTAINED IN ACCORDANCE WITH NFPA. ANNUAL INSPECTION HAS NOT BEEN COMPLETED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2020
Resolved 2 July 2020
Resolution: MAINTAINANCE AND INSPECTION WAS COMPLETED.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2020
Resolved
Pre-engineered fixed fire protection system had not been inspected annually. inspect the system annually in accordance with the NFPA.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2020
Resolved 2 July 2020
Resolution: fire protection system had its annual inspection conducted by servicing company.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 July 2020
Resolved
up to date charts appropriate for the voyage were not provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 14 July 2020
Resolution: CHARTS WERE PURCHASED AND PUT IN SERVICE
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 July 2020
Resolved
life floats must be seperated by spaces.
seperate life floats with spacers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 14 July 2020
Resolution: SPACERS WERE PLACED BETWEEN LIFE FLOATS
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 March 2019
Resolved
EPIRB and it's hydrostatic release were expired, vsl restricted to not more than 1000ft from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 1 April 2019
Resolution: New hydrostatic release was installed.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 March 2019
Resolved
Sea rails were not installed on the electric cooking range.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 1 April 2019
Resolution: Sea rails were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2019
Resolved
Electrical connectors were not the captive type at the 12vDC screw type terminal block.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 1 April 2019
Resolution: Ring type connectors were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2019
Resolved
Grounding strap across the flexible hose section of the fuel tank fill pipe was broken & disconnected.
Action required: 10 - Deficiency Rectified
Due 26 April 2019
Resolved 26 March 2019
Resolution: Fixed onsite to the satisfaction of the attending USCG marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 March 2019
Resolved
Bilge suction for the bow void compartment was connected to the potable water system instead of the bilge system. Bilge suction piping is to be disconnected from the potable water system and properly connected to the bilge sysem with a proper valve arrangement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 1 April 2019
Resolution: Satisfactory piping modifications were completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2019
Resolved
Overcurrent protection for the 12vDC electrical system used non-approved blade type fuses. Fuses must be the cartridge type that are UL-listed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2019
Resolved 2 July 2020
Resolution: MI from Houma provided photos of cartridge fuses installed where blade fuses used to be during the course of a late annual exam.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 November 2017
Resolved
Provide up to date tides and currents IAW 46 CFR 184.420
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 8 November 2017
Resolution: Vessel owner found current publications on board prior to departure of MI
Operations/Management › Drills/Instruction › Fire
Issued 8 November 2017
Resolved
Properly document training and drills IAW 46 CFR 185.420, 185.520 and 185.524
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 8 November 2017
Resolution: New logs were created for the drills and training conducted during the inspection that were to the satisfaction of the MI
Communications › Radio Communications › VHF Radiotelephone
Issued 8 November 2017
Resolved
Link GPS to VHF and program correct MMSI number on all radions IAW 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 7 December 2017
Resolution: Checked MMSI
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 November 2017
Resolved
Provide copy of DAPI policy and proof of enrollment IAW 46 CFR 16
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 12 January 2022
Resolution: Vessel under new owner and management with a valid DAPI program.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 8 November 2017
Resolved
Porvide locking device for stove and secure stove and refrigerator to prevent movement IAW 46 CFR 184.220
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 7 December 2017
Resolution: Checked locking device
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 November 2017
Resolved
Remove corrosion from battery terminals in engine room IAW 46 CFR 183.50
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 8 November 2017
Resolution: Battery terminals were cleaned up to the satisfaction of the marine inspector prior to departing the vessel
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 8 November 2017
Resolved
Provide proof that the generator has been derated to 80% of full load rating and label generator accordingly IAW 46 CFR 183.320
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 7 December 2017
Resolution: Checked new breaker (115amps) and sticker placement
Engineering › Fuel Oil Service System › Filter
Issued 8 November 2017
Resolved
Install flame shield on fuel filter IAW 46 CFR 182.455
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 7 December 2017
Resolution: Checked metal filter housing
Construction/Loadline › Hull › Hull Plating
Issued 26 June 2014
Resolved
Repair portside shaft log in aft steering compartment. Currently has pin holes and corroded. Make repairs prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2014
Resolved 21 June 2016
Resolution: Conducted DD exam all wasted areas cropped and renewed.
Construction/Loadline › Structures › End Bulkhead
Issued 26 June 2014
Resolved
Repair holed fwd bulkhead in aft steering portside.
Due 26 July 2014
Resolved 8 July 2014
Resolution: Examined approved repairs.
Stability › Unintentional Flooding › General
Issued 27 May 2014
Resolved
Make watertight through hole for throttle cable in aft steering compartment.
Due 26 July 2014
Resolved 8 July 2014
Resolution: Examined approved repairs.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 May 2014
Resolved
Failed to make vessel available for an annual inspection within 3 months before or after each anniversary date.
Due 27 May 2014
Resolved 27 May 2014
Resolution: Def resolved.
Construction/Loadline › Hull › Side Shell
Issued 2 August 2011
Resolved
Crop and renew holed side shell on the port side at the waterline.
Action required: 705 - Other - as specified
Due 2 August 2011
Resolved 4 August 2011
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 December 2010
Resolved
Company has not submitted required reports
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 17 December 2010
Resolution: Cleared by SECTOR NOLA DAPI.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 18 November 2010
Resolved
Replace pressure relief valve on both air receivers with correct pressure relief valves.
Action required: 705 - Other - as specified
Due 23 November 2010
Resolved 23 November 2010
Resolution: Pressure Relief valves were replaced on both air recievers.
Engineering › Fuel Oil Service System › Hose
Issued 18 November 2010
Resolved
Replace fuel hoses on starboard MDE. Current hoses are chaffed and split.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 23 November 2010
Resolution: Fuel hoses on starboard MDE were replaced.
Communications › Radio Communications › EPIRB
Issued 18 November 2010
Resolved
Hydrostatic release is expired. Renew hydrostatic release and ensure date is properly etched.
Action required: 705 - Other - as specified
Due 23 November 2010
Resolved 23 November 2010
Resolution: Hydrostatic release was replaced with new unit.
Electrical › Electric Supply System (service) › Cable
Issued 18 November 2010
Resolved
Replace positive lead on stbd battery bank. Cable is bare at terminal lead.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 23 November 2010
Resolution: Positive lead on starboard battery bank was replaced.
Lifesaving › Lifefloat › Lifeline
Issued 18 November 2010
Resolved
Replace polypropylene line connecting the two lifefloats. Line is deteriorated and rotten.
Action required: 705 - Other - as specified
Due 23 November 2010
Resolved 23 November 2010
Resolution: Polypropylene line was replaced between the two life floats.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 November 2010
Resolved
Crewmembers were unfamiliar with requirements for Drug and Alcohol testing and indicated they had not received training. Conduct drug awareness training with crew of vessel.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 17 December 2010
Resolution: Cleared by SECTOR NOLA DAPI.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 5 January 2010
Resolved
EPIRB battery is expired. Vessel route restricted to rivers until deficiency is cleared.
Action required: 705 - Other - as specified
Due 2 February 2010
Resolved 8 January 2010
Resolution: Battery was replaced and received successful EPIRB test verification report.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 March 2008
Resolved
Vessel needs 1 float light for life ring, existing one is missing.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2008
Resolved 3 March 2009
Resolution: Noted 1 lifering with required float light attached.
Communications › Audible Communications › Bell
Issued 3 March 2008
Resolved
Wrong size bell for vessel, need 8"
Due 4 April 2008
Resolved 3 March 2009
Resolution: Vessel has 8.5" bell in pilothouse.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 3 March 2008
Resolved
Need day shapes for vessel
Due 4 April 2008
Resolved 3 March 2009
Resolution: Dayshapes not required per Colregs due to size, service and route of vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 March 2008
Resolved
Need Not Under Command Lights
Due 4 April 2008
Resolved 3 March 2009
Resolution: Not Under Command lights not required per Colregs due to size, service and route of vessel.
Operations/Management › Passenger Operations › Safety Orientation
Issued 3 March 2008
Resolved
Need passenger orientation placard
Due 4 April 2008
Resolved 3 March 2009
Resolution: Passenger oientation placards mounted on aft bulkhead in main deck passenger compartment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2008
Resolved
Need metal wire clamps in engine and steering gear room
Due 4 April 2008
Resolved 3 March 2009
Resolution: Metal wire clamps were found in engine and steering gear room.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 March 2008
Resolved
Need cover mounted on panel in steering gear room
Due 4 April 2008
Resolved 3 March 2009
Resolution: Cover mounted on panel in steering gear room.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 March 2008
Resolved
Two (2) flex hoses from fuel tank need to replaced in the steering gear room.
Due 4 April 2008
Resolved 7 April 2009
Operations/Management › Pollution › Control of Garbage
Issued 23 May 2007
Resolved
Vessel must obtain and post waste management plan.
Due 22 June 2007
Resolved 7 December 2007
Resolution: Waste management plan posted.
Accommodation/Occupational Safety › Potable Water System › General
Issued 23 May 2007
Resolved
Install insect screens on potable water vent.
Due 22 June 2007
Resolved 7 December 2007
Resolution: Insect screen installed in vent.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 May 2007
Resolved
Renew lagging on exhaust on stbd main engine.
Due 22 June 2007
Resolved 7 December 2007
Resolution: New lagging installed on port MDE.
Engineering › Electric Propulsion System › Wiring
Issued 23 May 2007
Resolved
Repair engine tachometer for stbd main engine.
Due 22 June 2007
Resolved 7 December 2007
Resolution: Engine tac repaired and operating correctly
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 May 2007
Resolved
Operator failed to make vessel available for inspection.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 23 May 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 27 October 2005
Resolved
Replace missing light covers in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 7 December 2007
Resolution: Missing light covers replaced.
Lifesaving › Lifefloat › Lifeline
Issued 27 October 2005
Resolved
Replace deteriorated line to weak link.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 22 May 2007
Resolution: Line replaced and in good condition
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 October 2005
Resolved
Bilge alarms improperly wired. Bilge alarms are installed in engine room, crew quarters and engineering space. Alarm indicators on bridge only activate for engine room regardless of which bilge alarm was tested.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 7 December 2007
Resolution: Bilge alarm repaired and is operating correctly
Communications › Radio Communications › EPIRB
Issued 27 October 2005
Resolved
Hydrostatic release is expired.
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 22 May 2006
Resolution: Hydrostatic release replaced.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 October 2005
Resolved
Replace outdated pubs and charts.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 7 December 2007
Resolution: New nav charts on publications installed onboard.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 27 October 2005
Resolved
Repair anchor light.
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 22 May 2007
Resolution: Anchor light repaired and burning brightly.
Engineering › Fuel Oil Service System › Ventilation
Issued 27 October 2005
Resolved
Replace fuel vent flame screens.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 22 May 2007
Resolution: Flame screen for fuel vent in place and in good condition.
Engineering › Fuel Oil Service System › Ventilation
Issued 27 October 2005
Resolved
Prove proper operation of vent closures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 22 May 2007
Resolution: Vent closures close properly.
Engineering › Generator (propulsion/auxiliary-electric) › Outlet Box
Issued 27 October 2005
Resolved
Properly label shore power generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2005
Resolved 22 May 2007
Resolution: Panel labled properly.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 20 May 2003
Resolved
Prove B-1 fire extinguisher above stove has been serviced within one year. LEGACY COMPONENT DESC: Service
Due 20 June 2003
Resolved 19 June 2003
Navigation › Piloting/Steering
Issued 20 May 2003
Resolved
Provide up-to-date publications. LEGACY COMPONENT DESC: Publications
Due 20 June 2003
Resolved 19 June 2003
Communications › Radio Communications
Issued 20 May 2003
Resolved
Replace EPIRB batteries and hydrostatic release. Vessel may not operate beyond 3 miles from land until corrected. LEGACY COMPONENT DESC: EPIRB
Due 20 June 2003
Resolved 19 June 2003
Lifesaving › Buoyant Apparatus
Issued 20 May 2003
Resolved
Correct the following problems on the lifefloats: provide new weak link or prove the strength of the existing one; attach light to lower life float; attach paddles to the lifefloats; properly splice lines from the floats to the weak link. Vessel may not operate outside the river until corrected.
Due 20 June 2003
Resolved 19 June 2003
Engineering › Compressed Air System (start air)
Issued 20 May 2003
Resolved
By pass the small air reciever in main engine compartment so that the larger air receiver relief valve can be tested OR have the small air receiver MAWP certified by a shop.
Due 20 June 2003
Resolved 19 June 2003
Fire Fighting › Means of Escape
Issued 20 May 2003
Resolved
Mark crew quarters emergency exit from above with "Emergency Exit - Keep Clear." LEGACY COMPONENT DESC: Escape Route Signs
Due 20 June 2003
Resolved 19 June 2003
Navigation
Issued 29 July 2002
Resolved
PROVE CHARTS ARE BEING UPDATED.
Condition: Improper/Lack of Maintenance
Due 30 August 2002
Resolved 22 August 2002
Engineering › Bilge Water Management System
Issued 29 July 2002
Resolved
INSTALL STRAINER IN FOREPEAK ON BILGE PUMP. LEGACY COMPONENT DESC: Strainer
Condition: Unknown
Due 30 August 2002
Resolved 22 August 2002
Lifesaving › Buoyant Apparatus
Issued 29 July 2002
Resolved
REPAIR 12 MAN LIFEFLOAT AT APPROVED FACILITY. VESSEL IS RESTRICTED TO 12 TOTAL PERSONS ONBOARD UNTIL LIFEFLOAT IS BACK IN SERVICE. REPAIRS NEED TO BE CHECKED BY AN ATTENDING MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Due 30 August 2002
Resolved 22 August 2002
Engineering › Bilge Water Management System
Issued 29 July 2002
Resolved
PROVIDE AND INSTALL HIGH LEVEL BILGE ALARM IN STEERING COMPARTMENT. LEGACY COMPONENT DESC: ALARM
Condition: Unknown
Due 30 August 2002
Resolved 22 August 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 July 2002
Resolved
PROVIDE AND INSTALL GUARDS OVER ROTATING MACHINERY IN ENGINE ROOM.
Condition: Unknown
Due 30 August 2002
Resolved 22 August 2002
Engineering › Pressure Vessel
Issued 29 July 2002
Resolved
PROVIDE AND INSTALL PROPER GUAGE ON AIR RECEIVER. LEGACY COMPONENT DESC: Pressure Gauge
Due 30 August 2002
Resolved 22 August 2002
Engineering › Sea-water System (primary cooling)
Issued 29 July 2002
Resolved
MAKE PROPER REPAIRS TO SALT WATER COOLING PUMP LINE AND BULKHEAD PENETRATION IWO MID BODY VOID. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 30 August 2002
Resolved 22 August 2002
Electrical
Issued 20 February 2001
Resolved
LABEL BREAKER FOR STOVE AND LABEL OUTSIDE OF BREAKER BOX IN RED FOR STOVE DISCONNECT.
Condition: Unknown
Due 20 March 2001
Resolved 21 February 2001
Documentation
Issued 20 February 2001
Resolved
PROCURE SUBCHAPTER "T" 46 CFR FOR THE VESSEL.
Condition: Unknown
Due 20 March 2001
Resolved 13 March 2001
Navigation
Issued 20 February 2001
Resolved
PROVE CHARTS ARE BEING UPDATED.
Condition: Unknown
Due 20 March 2001
Resolved 13 March 2001
Lifesaving
Issued 20 February 2001
Resolved
REPLACE HYDROSTATIC RELEASE ON EPIRB AND PUNCH OUT DATES.
Condition: Unknown
Due 20 March 2001
Resolved 21 February 2001
Lifesaving
Issued 20 February 2001
Resolved
REPLACE CLIP ON LIFE RING WITH A NON CORROSIVE ONE.
Condition: Unknown
Due 20 March 2001
Resolved 21 February 2001
Engineering
Issued 20 February 2001
Resolved
INSTALL NEW RELIEF VALVES ON BOTH AIR COMPRESSORS. PROVE RELIEF VALVES WORKBELOW MAXIMUM ALLOWABLE WORKING PRESSURE OF THE TANK.
Condition: Unknown
Due 20 March 2001
Resolved 13 March 2001
Engineering
Issued 12 November 1998
Resolved
PROVIDE BELT GUARDS FOR S/S GEN.
Condition: Unknown
Due 12 November 1998
Resolved 12 November 1998
Engineering
Issued 12 November 1998
Resolved
PROVIDE BELT GUARD FOR FRONT OF SMDE.
Condition: Unknown
Due 12 November 1998
Resolved 12 November 1998
Navigation
Issued 7 August 1997
Resolved
Provide deviation compass card for magnetic compass.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Documentation
Issued 7 August 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Engineering
Issued 7 August 1997
Resolved
Provide plug for port fuel oil filter impingment screen.
Condition: Unknown
Due 7 August 1997
Resolved 11 August 1997
Construction/Loadline
Issued 7 August 1997
Resolved
Provide double hose clamps for all flex hoses in engine room with direct access to the sea.
Condition: Unknown
Due 7 August 1997
Resolved 11 August 1997
Documentation
Issued 7 August 1997
Resolved
Provide new copy of 46 CFR 166-199 (1995 version).
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Construction/Loadline
Issued 7 August 1997
Resolved
Remove flex hose from stbd fwd sea chest to bilge manifold from fuel oil line, and properly cap fittings.
Condition: Unknown
Due 7 August 1997
Resolved 11 August 1997
Documentation
Issued 7 August 1997
Resolved
Provide valid FCC Safety Radio Telephony certificate. Vessel restricted towithin a 1000 feet from shore until provided.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Documentation
Issued 10 October 1995
Resolved
Provide satisfactory documentation that the marine employer has an established chemical testing program as identified in 46 CFR part 16.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Engineering
Issued 10 August 1995
Resolved
INSTALL PLUGS OR CAPS ON RACOR FILTER DRAINS.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Engineering
Issued 10 August 1995
Resolved
INSTALL 30X30 CORROSION RESISTANT FLAME SCREEN ON ALL FUEL VENTS.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Electrical
Issued 10 August 1995
Resolved
BLANK OFF OPEN BREAKER ON BRIDGE POWER PANEL.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Electrical
Issued 10 August 1995
Resolved
INSTALL JUNCTION BOX FOR SPLICED WIRING UNDER PASSENGER DECK.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Electrical
Issued 14 July 1994
Resolved
REMOVE HOUSEHOLD WIRING ON VESSELS BRIDGE. REPLACE WIRE NUTS UNDER VESSELSSTEERING CONSOLE WITH CRIMP FITTINGS.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Construction/Loadline
Issued 14 July 1994
Resolved
REPAIR/REPLACE DAMAGED PORTION OF STERN RUB RAIL AND GOUGE AND REWELD BROKEN WELDS IN STERN VOID LOCATED AT TOP OF AFT BULKHEAD.
Condition: Unknown
Due 14 August 1994
Resolved 26 July 1994
Engineering
Issued 14 July 1994
Resolved
PROVIDE FLAME SCREEN ON VESSELS FUEL TANK VENT.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Electrical
Issued 14 July 1994
Resolved
REPLACE HAND SPLICES IN LIGHTING WIRES AT OPENING OF ENGINE ROOM WITH CRIMPFITTINGS AND PLACE COVER/GLOBE OVER OLD LIGHT FIXTURE.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Deck/Cargo
Issued 14 July 1994
Resolved
PROVIDE AND PROVE PROPER OPERATION OF VESSELS ANCHOR WINDLESS.
Condition: Unknown
Due 14 July 1994
Resolved 14 July 1994
Engineering
Issued 21 January 1993
Resolved
MAKE VESSELS AIR RECEIVERS AVAILABLE FOR AN INTERNAL EXAM AND DEMONSTRATE PROPER OPERATION OF THE RELIEF VALVES ON SAME.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Documentation
Issued 13 August 1992
Resolved
PROVE PROPER VESSEL DOCUMENTATION.
Condition: Unknown
Due 20 August 1992
Resolved 17 August 1992
Construction/Loadline
Issued 1 December 1989
Resolved
INSTALL AUTOMATIC NON RETURN VALVE IN SCUBA TANK FILLING STATION DRAIN LINEAS CLOSE AS POSSIBLE TO THE HULL.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989