← All vessels
PETIT CHAM
PETIT CHAM is a freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in August 2022, along with 7 deficiencies and 1 operational control, 1 with no removal date recorded.
Records from 2016 to 2022. Most recent: inspection, 23 August 2022.
- Built
- Not recorded
- Last inspected
- 23 August 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9637210 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRLG7
1230782
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1230782
Inspections, by type
…with no type recorded1
Years with a record
4 calendar years (2016–2022)
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it36332 - Regulatory (Subpart C or D), Gross Ton
36332 - Convention (Subpart B), Gross Ton
63525 - Dead Weight, Ton
36332 - Convention (Subpart B), Gross Ton
63525 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
23 August 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7541431
2 July 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7493000
12 November 2020
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7093838
15 October 2020
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7073912
8 October 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7073964
15 December 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6321037
21 October 2016
ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6029346
Deficiency record · 7
14 - Pollution Prevention › 148 - Ballast Water › Extraordinary Condition Claims
Issued 2 July 2022
Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 16 October 2020
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Batter connections for emergency generator were found zip tied to battery terminal posts. Wire connecting batteries for 24V configuration does not appear to be of original installation design.
74 SOLAS (2014) II-1/45.1.2 50ac
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. Hydraulic system for #1 cargo hold found leaking at flange, at frame 137, inboard.
74 SOLAS (2014) I/11 50ac
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 15 December 2017
Resolved
9900- Other(not clearly hazardous)-The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The gasket on a flange within the oil purifier system was corroded and leaking water. 74 SOLAS (2014) II-1/26.1-40ac
Engineering › Bilge Water Management System › Piping
Issued 15 December 2017
Resolved
9900- Other(not clearly hazardous)-The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The pipe by the OWS system is leaking into the bilge. 74 SOLAS (2014) II-1/26.1-40ac
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 15 December 2017
Resolved
0725-Fixed fire extinguishing installation-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The line connecting CO2 cylinder 33 to cylinder 34 was disconnected. 74 SOLAS(2014)II-2/14.2.1.2-10c
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 15 December 2017
Resolved
1420-Cleanliness of Engine Room-Provisions shall be made to facilitate cleaning, inspection, and maintenance of auxiliary machinery. There was an excessive amount of oil in the containment surrounding the generators. 74 SOLAS (2014) II-1/26.7 10c
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.