MAURY USCG vessel records Sign in
← All vessels

JASMAN

JASMAN is a 1972 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 1994, most recently in November 2016, along with 19 deficiencies, 1 operational control and 2 casualty investigations between 2006 and 2013.

Records from 1994 to 2016. Most recent: inspection, 29 November 2016.

Built
1972
Last inspected
29 November 2016
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF8362
123092
Flag
UNITED STATES
367494060 (licence lapsed)
Maury page id
psix-123092

Inspections, by type

…with no type recorded1
Years with a record 17 calendar years (1994–2016)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)52.9 ft × 16.0 ft × 10.5 ft
Registered tonnagegross 51 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJAMES R. HITZ · BELLINGHAM, WA, UNITED STATES · built 1972
Hull materialConcrete
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF8362MMSI 367494060 · expired · compulsorily equipped · granted 9 June 2011, cancelled 14 August 2021 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 30

29 November 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6049210
6 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203267
20 July 2011 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4088080
21 December 2009 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3653663
15 April 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3451534
22 July 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3274952
20 July 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3001509
9 May 2007 Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2925945
18 July 2006 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2717072
14 July 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2719571
1 June 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2667356
4 June 2005 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2378828
24 May 2005 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2369696
9 May 2005 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2353465
26 May 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2079152
19 June 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1832096
28 May 2003 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1804098
6 June 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395762
22 May 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366352
5 June 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470803
2 July 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1087676
1 June 1999 Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1464849
20 July 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411716
17 June 1997 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1407903
2 July 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1089589
13 June 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1396534
1 August 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1184313
21 March 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 869516
11 October 1994 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1175273
7 June 1994 Hull Examination · COI Inspection · Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1419290

Deficiency record · 19

Documentation › Markings/Placards › Garbage Placard
Issued 12 August 2008 Resolved
Affix Garbage Placards.
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 12 August 2008
Resolution: Fixed on the spot w/ supplied placards.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 August 2008 Resolved
Provide one additional PFD to bring total count onboard in compliance with total persons allowed per COI.
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 12 August 2008
Resolution: Added additional PFD to vsl supply from extra stock in shore storage. PFD count in compliance.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 May 2007 Resolved
At entrance to engine room, starboard side above ladder, 2 cracks were in concrete ceiling; proposed them to be filled in.
Action required: 705 - Other - as specified
Resolved 29 May 2007
Resolution: Owner/operater found rust behind concrete causing the crack. Crack repaired. Received pictures to verify fix.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 1 June 2006 Resolved
Operator didn't ensure First Aid Cards for 50% of crew were availabe during inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2006
Resolution: provided documentation via fax.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 June 2006 Resolved
Replace leaking gasket on sea strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 2 June 2006
Resolution: Renewed gasket.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 May 2005 Resolved
Repair bilge line fractured in way of #2 void.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 27 May 2005
Resolution: Repairs complete and operational test conducted.
Construction/Loadline
Issued 1 June 1999 Resolved
SUBMIT PLANS FOR APPROVAL AND INSTALL A HIGH LEVEL ALARM SYSTEM THAT MEETS THE REQUIREMENTS OF 46CFR182.530.
Condition: Unknown
Due 1 June 1999
Resolved 13 July 1999
Construction/Loadline
Issued 1 June 1999 Resolved
SUBMIT PLANS FOR APPROVAL AND INSTALL A FIXED BILGE PIPING SYSTEM THAT MEETS THE REQUIREMENTS OF 46CFR182.510.
Condition: Unknown
Due 1 June 1999
Resolved 13 July 1999
Engineering
Issued 20 July 1998 Resolved
Install diesel fuel supply piping and fuel oil shut off valves as per 46CFR182.20-40.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Lifesaving
Issued 20 July 1998 Resolved
Liquid Compressed Gas system needs to be installed as per ABYC. System to be closed at the supply valve and not used until corrected. Instruction labels are missing and storage tank improperly installed.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Navigation
Issued 17 June 1997 Resolved
PROVIDE DEVIATION CARD.
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Construction/Loadline
Issued 17 June 1997 Resolved
SUBMIT PLAN FOR APPROVAL AND INSTALL A BILGE SYSTEM TO MEET 46 CFR 182.510.
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Documentation
Issued 13 June 1996 Resolved
PROVIDE DOCUMENTATION OF A CG APPROVED DRUG TESTING PROGRAM ON BOARD VESSEL
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Engineering
Issued 13 June 1996 Resolved
FUEL CUTOFF VALVE SIGNS MARKING LOCATION OF PORT AND STARBOARD FUEL CUTOFF VALVES MISSING.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Documentation
Issued 7 June 1994 Resolved
Provide valid radiotelephne cerificate.
Condition: Unknown
Due 23 June 1994
Resolved 21 July 1994
Construction/Loadline
Issued 7 June 1994 Resolved
Provide label for watertight combing for aft cabin to read "This combing toremain in place except during transit"
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994
Fire Fighting
Issued 7 June 1994 Resolved
Provide approved marine brackets for all BII extinguishers
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994
Accommodation/Occupational Safety
Issued 7 June 1994 Resolved
Provide labeling for MSD to read "overboard valve to remain closed while inU.S. waters"
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994
Lifesaving
Issued 7 June 1994 Resolved
Passengers are limited to 46 until 3 additional adult PFDs are provided.
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994

Casualty record · 2

14 July 2006Routine · role: Involved in a Marine Casualty · activity 2719571
30 November 2013Routine · role: Alleged Pollution Source · activity 4762178
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SHAWMANEE (2006–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record