Records from 1994 to 2016. Most recent: inspection, 29 November 2016.
Documentation record
Registered dimensions (L × B × D)52.9 ft × 16.0 ft × 10.5 ft
Registered tonnagegross 51 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJAMES R. HITZ · BELLINGHAM, WA, UNITED STATES · built 1972
Hull materialConcrete
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
29 November 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6049210
6 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203267
20 July 2011
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4088080
21 December 2009
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3653663
15 April 2009
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3451534
22 July 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3274952
20 July 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3001509
9 May 2007
Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2925945
18 July 2006
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2717072
14 July 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2719571
1 June 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2667356
4 June 2005
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2378828
24 May 2005
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2369696
9 May 2005
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2353465
26 May 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2079152
19 June 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1832096
28 May 2003
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1804098
6 June 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395762
22 May 2001
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366352
5 June 2000
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470803
2 July 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1087676
1 June 1999
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1464849
20 July 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411716
17 June 1997
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1407903
2 July 1996
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1089589
13 June 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1396534
1 August 1995
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1184313
21 March 1995
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 869516
11 October 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1175273
7 June 1994
Hull Examination · COI Inspection · Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1419290
Documentation › Markings/Placards › Garbage Placard
Issued 12 August 2008
Resolved
Affix Garbage Placards.
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 12 August 2008
Resolution: Fixed on the spot w/ supplied placards.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 August 2008
Resolved
Provide one additional PFD to bring total count onboard in compliance with total persons allowed per COI.
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 12 August 2008
Resolution: Added additional PFD to vsl supply from extra stock in shore storage. PFD count in compliance.
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 May 2007
Resolved
At entrance to engine room, starboard side above ladder, 2 cracks were in concrete ceiling; proposed them to be filled in.
Action required: 705 - Other - as specified
Resolved 29 May 2007
Resolution: Owner/operater found rust behind concrete causing the crack. Crack repaired. Received pictures to verify fix.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 1 June 2006
Resolved
Operator didn't ensure First Aid Cards for 50% of crew were availabe during inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2006
Resolution: provided documentation via fax.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 June 2006
Resolved
Replace leaking gasket on sea strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 2 June 2006
Resolution: Renewed gasket.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 May 2005
Resolved
Repair bilge line fractured in way of #2 void.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 27 May 2005
Resolution: Repairs complete and operational test conducted.
Construction/Loadline
Issued 1 June 1999
Resolved
SUBMIT PLANS FOR APPROVAL AND INSTALL A HIGH LEVEL ALARM SYSTEM THAT MEETS THE REQUIREMENTS OF 46CFR182.530.
Condition: Unknown
Due 1 June 1999
Resolved 13 July 1999
Construction/Loadline
Issued 1 June 1999
Resolved
SUBMIT PLANS FOR APPROVAL AND INSTALL A FIXED BILGE PIPING SYSTEM THAT MEETS THE REQUIREMENTS OF 46CFR182.510.
Condition: Unknown
Due 1 June 1999
Resolved 13 July 1999
Engineering
Issued 20 July 1998
Resolved
Install diesel fuel supply piping and fuel oil shut off valves as per 46CFR182.20-40.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Lifesaving
Issued 20 July 1998
Resolved
Liquid Compressed Gas system needs to be installed as per ABYC. System to be closed at the supply valve and not used until corrected. Instruction labels are missing and storage tank improperly installed.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Navigation
Issued 17 June 1997
Resolved
PROVIDE DEVIATION CARD.
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Construction/Loadline
Issued 17 June 1997
Resolved
SUBMIT PLAN FOR APPROVAL AND INSTALL A BILGE SYSTEM TO MEET 46 CFR 182.510.
Condition: Unknown
Due 17 June 1997
Resolved 17 June 1997
Documentation
Issued 13 June 1996
Resolved
PROVIDE DOCUMENTATION OF A CG APPROVED DRUG TESTING PROGRAM ON BOARD VESSEL
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Engineering
Issued 13 June 1996
Resolved
FUEL CUTOFF VALVE SIGNS MARKING LOCATION OF PORT AND STARBOARD FUEL CUTOFF VALVES MISSING.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Documentation
Issued 7 June 1994
Resolved
Provide valid radiotelephne cerificate.
Condition: Unknown
Due 23 June 1994
Resolved 21 July 1994
Construction/Loadline
Issued 7 June 1994
Resolved
Provide label for watertight combing for aft cabin to read "This combing toremain in place except during transit"
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994
Fire Fighting
Issued 7 June 1994
Resolved
Provide approved marine brackets for all BII extinguishers
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994
Accommodation/Occupational Safety
Issued 7 June 1994
Resolved
Provide labeling for MSD to read "overboard valve to remain closed while inU.S. waters"
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994
Lifesaving
Issued 7 June 1994
Resolved
Passengers are limited to 46 until 3 additional adult PFDs are provided.
Condition: Unknown
Due 29 July 1994
Resolved 3 August 1994