Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Inspection history · 18
4 March 2026
Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8320129
11 March 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8094117
26 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8085939
14 January 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8060254
11 March 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872653
23 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7626795
14 December 2022
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7601777
5 January 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7378748
24 June 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7233697
26 January 2021
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7131519
22 October 2019
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6845309
2 September 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6802127
13 August 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6783054
22 January 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6615094
11 January 2018
COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6335507
15 November 2017
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6307276
22 June 2017
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6180471
22 September 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6006997
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems, it must be SAE J-1942 or be specifically approved by the Commandant. In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required. Flexible J1942 fuel hoses from fuel tank to the filter were severely corroded and must be replaced. Flexible hoses from the filter to outboards were not J1942 and not double hose clamped. Ensure all approved fuel lines that are not J1942 are double hose clamped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 11 March 2025
Resolution: Attended vessel, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 February 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Marine Inspector observed multiple dead-end wires identified under steering console. Vessel must adequately removed or cap all dead-end wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 11 March 2025
Resolution: Attended vessel, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 February 2025
Resolved
Portable fire extinguisher installation must be to the satisfaction of the Officer in Charge, Marine Inspection. Marine Inspector observed brackets either wasted or missing. Vessel must replace and install brackets for each portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 11 March 2025
Resolution: Attended vessel, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 February 2025
Resolved
A vessel not required to have a power drive fire pump must have at least three 2.5 gallon buckets with the words "FIRE BUCKET" stenciled in contrasting color on each bucket. Marine Inspector observed one bucket was over 2.5 gallons and was not properly stenciled. Vessel must have three 2.5 gallon buckets all stenciled properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 11 March 2025
Resolution: Attended vessel, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 February 2025
Resolved
A vessel must carry one floating waterlight. Marine Inspector observed the battery was expired for the lifering buoy waterlight. Vessel must replace battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2025
Resolved 11 March 2025
Resolution: Attended vessel, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 December 2022
Resolved
Inspect hull in accordance with 46 CFR 176.802. Three keel stiffener planks were pulling away from hull. Repair at January 2023 drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 15 February 2023
Resolution: Keel stiffeners repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 January 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterline. The port amidships high water level alarm was not functional.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2022
Resolved 1 February 2022
Resolution: Attended vessel verified H/W alarm worked as designed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 January 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's navigation lights were not functioning.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2022
Resolved 1 February 2022
Resolution: Attended vessel witnessed proper operation of navigation lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2022
Resolved
An adult life jacket must be provided for each person carried on board. in additino, child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. 06 child and 01 adult life jackets were highly deteriorated and must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2022
Resolved 7 February 2022
Resolution: Received photo from O/O showing new lifejackets onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 January 2022
Resolved
Vessel must carry a minimum of three hand red distress signals and three orange smoke distress signals. Vessel only had 4 hand red distress signals present on board. Provide additional flares IAW 46CFR180.68
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2022
Resolved 1 February 2022
Resolution: Attended vessel verified proper number of flares onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 January 2022
Resolved
Portable and semi-portable extinguishers must be inspected and maintained IAW NFPA 10. Inspection and maintenance records were not available for inspection and must be provided.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2022
Resolved 1 February 2022
Resolution: Attended vessel verified new/certified fire extinguishers were onboard.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 June 2021
Resolved
Conduct interior hull inspection in accordance with 46 CFR176.802. Fwd port bilge stiffener noted in special note was repaired during off season. Repair was beginning to separate. Provide satisfactory long term repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 14 July 2021
Resolution: Proposal provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 June 2021
Resolved
Inspect bilge alarms in accordance with 46 CFR 176.804. Fwd port bilge alarm was inoperative.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 14 July 2021
Resolution: Alarm satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 June 2021
Resolved
Conduct interior hull inspection in accordance with 46 CFR176.802. Fwd port bilge stiffener noted in special note was repaired during off season. Repair was beginning to separate. Satisfactory long term repair proposal was provided to be completed by 31 Jan 22. Monitor separation and notify MSD PANAMA CITY if further damage occurs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2022
Resolved 25 January 2022
Resolution: Witnessed satisfactory repair of fwd port bilge stiffener.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 January 2019
Resolved
Vessle missing night flares.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 February 2019
Resolution: New flares placed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 January 2019
Resolved
Vessel Navigation lights inoperable. Provide proof of properly operating Navigation lights.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 January 2019
Resolution: Navigation lights operational, corrected prior to departure.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2019
Resolved
Replace broken fire extinguisher bracket in bar area.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 February 2019
Resolution: New bracket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 January 2019
Resolved
Replace or renew life rings, properly install lights and line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
Resolution: New Life ring and light line clip installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 22 January 2019
Resolved
Mount Life jacket donning placard.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2019
Resolution: New sign posted.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 22 January 2019
Resolved
Properlydisplay Emergency Prodedure Instructions.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
Resolution: Procedures provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 January 2019
Resolved
Provide proof of proper operation of propulsion and electrical system.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 January 2019
Resolution: Demonstrated propulsion and electrical system test, all sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2018
Resolved
Prove Proper Operation of the vessel's nav lights
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2018
Resolved 25 January 2018
Engineering › Bilge Water Management System › Not Operational
Issued 11 January 2018
Resolved
Repair Bilge High Water Alarms to ensure an audible alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2018
Resolved 25 January 2018
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 11 January 2018
Resolved
Provide 2 more life jackets. Max persons on board reduced by 2.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 25 January 2018
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 January 2018
Resolved
Conduct crew drill (Prior to COI issued).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2018
Resolved 25 January 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 November 2017
Resolved
Complete a credit annual exam. Vessel annual exam is overdue as of 02Oct17
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2017
Resolved 25 January 2018
Engineering › Fuel Oil Service System › Tank
Issued 22 September 2016
Resolved
Fuel tank ground was missing
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 29 September 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 September 2016
Resolved
First Aid kit was out of date
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 29 September 2016
Resolution: First aid kit was replaced.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 22 September 2016
Resolved
Coast pilot was missing
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 29 September 2016
Resolution: Coast Pilot was replaced.