MAURY USCG vessel records
← All vessels

BRISTOL WIND

BRISTOL WIND is a 2013 towing vessel. The Coast Guard has recorded 14 inspections since 2013, most recently in May 2026, along with 14 deficiencies.

Records from 2013 to 2026. Most recent: inspection, 21 May 2026.

Built
2013
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG8362
1231151
Flag
UNITED STATES
Maury page id
psix-1231151

Inspections, by type

Years with a record 9 calendar years (2013–2026)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)76.1 ft × 32.1 ft × 7.1 ft
Registered tonnagegross 145 / net 116
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFOSS MARITIME · RAINIER, OR, UNITED STATES · built 2013
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portANCHORAGE, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it145 - Simplified, Gross Ton
116 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 14

21 May 2026 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8358952
11 March 2026 Examination of Repairs · Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8327718
28 August 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8210103
9 July 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8180490
20 June 2024 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7939572
13 June 2024 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7936954
14 June 2023 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7716551
28 March 2023 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7658359
25 May 2022 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7458614
2 June 2021 Administrative Inspection · Initial Certification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7191916
20 April 2020 Administrative Inspection · Initial Certification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6972462
5 March 2018 Liferaft Servicing
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6367182
5 March 2018 Liferaft Servicing
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6367186
18 June 2013 MTSA/ISPS Verification · Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4630138

Deficiency record · 14

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either: A flammable liquid storage cabinet that satisfies UL 1275 or FM Approvals Standard 6050. A suitable flammable locker is not installed onboard for the storage of flammable materials.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Flammable products were found stored throughout the engine room and not in a flammable storage cabinet.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 August 2025 Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. A 40-B portable fire extinguisher is not installed in the proposed location for the new flammable locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 August 2025 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. The emergency lighting in the engine room was found to be inoperable and not providing sufficient illumination of escape routes.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 August 2025 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. The watertight hatch on the main deck leading to the engine room was unable to close and create a watertight seal.
Action required: 15 - Rectify deficiencies by next port
Due 11 September 2025
Resolved 29 August 2025
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 August 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. The starboard rudder stock packing gland was found to be leaking excessively and causing substantial build up of water in the lazarrette.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 29 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 28 August 2025 Resolved
The line throwing appliance must have an auxiliary line that: s at least 450 meters (1,500 feet) long; Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force); and Is, if synthetic, of a dark color or certified by the manufacturer to be resistant to deterioration from ultraviolet light. The auxiliary line was not onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 22 October 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 Resolved
Each watertight hatch must be marked on both sides in clearly legible letters at least (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. The watertight hatches on the main deck were not labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2025
Resolved 2 September 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 August 2025 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Tests of "Charge of storage batteries if the vessel is so equipped, for emergency lighting and power" must be completed "At least once every 3 months." The test of the storage batteries for the emergency lighting and power was not recorded in the Towing Vessel Record.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2025
Resolved 26 September 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 June 2024 Resolved
Emergency lighting must be provided for all internal crew working and living areas. All battery back-up emergency lighting for the machinery space is inoperable, replace batteries for emergency lighting in machinery space. 46 CFR 143.410(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2024
Resolution: Received photographs of E-lighting operational while vessel is "dark ship".
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2024 Resolved
There must be an installed or portable bilge pump for emergency dewatering. A pin hole leak was found on the bilge piping suction line for the machinery space inhibiting emergency dewatering, provide repair plan for bilge piping system. 46 CFR 143.275 21JUN2024: Received repair plan from Port Engineer to conduct permanent repair of the pin hole in the machinery space piping at the end of the operating season in October 2024. Extended deficiency to 31OCT24 to conduct permanent repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 9 July 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2024 Resolved
Simple, complete operating instructions must be conspicuously located at or near any release station and in the extinguishing agent cylinder storage room. The fixed fire extinguishing system did not have instructions or schematic diagram at the storage room, place instructions and schematic diagram in the storage room. 46 CFR 136.110 46 CFR 95.16-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 11 July 2024
Resolution: Instructions were posted in the stowage room.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 June 2024 Resolved
The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician. The recently installed Sea-Fire Marine fire detection system does not have a record of the installation being certified by NICET Level IV technician, provide proof of fire detection system certification by NICET level IV technician. 46 CFR 142.330(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 30 July 2024
Resolution: Received NICET Level IV certification of fire detection system. Uploaded to vessel documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2024 Resolved
Each crew berthing area shall be equipped with information regarding vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, drug and alcohol usage, and procedures and resources to report crimes. No information regarding company policies or resources were posted in crew staterooms, post required information in staterooms. 46 U.S.C. 11101(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 11 July 2024
Resolution: Company policies and procedures on SASH was posted in staterooms.

Ownership record