MAURY USCG vessel records Sign in
← All vessels

FINCH ARROW

FINCH ARROW is a 2013 freight ship. The Coast Guard has recorded 8 inspections since 2014, most recently in November 2025, along with 3 deficiencies.

Records from 2014 to 2025. Most recent: inspection, 6 November 2025.

Built
2013
Last inspected
6 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9574860 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1231153
Flag
PANAMA
—
Maury page id
psix-1231153

Inspections, by type

Years with a record 7 calendar years (2014–2025)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it84740 - Displacement, Metric Ton
69990 - Dead Weight, Metric Ton
46295 - Convention (Subpart B), Gross Ton
21763 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

6 November 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8261411
21 October 2022 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7581520
19 October 2022 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7573944
22 October 2020 PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7078919
27 September 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6822607
27 November 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6309218
4 September 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5229286
2 June 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4872271

Deficiency record · 3

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 October 2022 Resolved
The machiery, boilers, and other pressure vessels, assosicted iping systems and fittings shall be of a design and construction adequate for the service for this the are intended...Vessel experienced a high temperature alarm on the M/E #3 cylinder exhaust. 74SOALS (20)/II-1, Reg 26.1 (17ac)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2022
Resolution: Vessel crew examine the injectors and the exhaust valve. Leakage of Lube Oil from broken oil seal identified. The defective valve was replaced with properly tested spare parts.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 19 October 2022 Resolved
Cite: 46 CFR 162.060-22 (a) Each Ballast Water Management System (BWMS) manufactured under Coast Guard approval must have name plate which is securely fastened to the BWMS and plainly marked by the manufacturer with the information listed in paragraph (b) of this section. BWMS does not have a nameplate with the information required in paragraph (b)of this section.
Action required: 10 - Deficiency Rectified
Due 19 October 2022
Resolved 19 October 2022
Resolution: Corrected on spot, crew had nameplate ordered and received it prior to arrival at Port Hueneme but did not attach it to the BWMS system. Crew attached it after being notified by PSCO.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 October 2022 Resolved
Cite: 74 SOLAS (20 Cons.) II-2/14.2.1.2 Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed Fire Main valve in the Fire contol station was in the closed position and not ready for immediate use.
Action required: 10 - Deficiency Rectified
Due 19 October 2022
Resolved 19 October 2022
Resolution: Fire main valve was opened by crew after being notified by PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.