MAURY USCG vessel records
← All vessels

JAYDEN

JAYDEN is a 2012 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in January 2026, along with 43 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 19 January 2026.

Built
2012
Last inspected
19 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1231247
Flag
MICRONESIA, FEDERATED STATES OF
Maury page id
psix-1231247

Inspections, by type

Years with a record 8 calendar years (2016–2026)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it63 - Simplified, Gross Ton
56 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

19 January 2026 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8296105
25 November 2024 PSC C
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8036074
5 December 2022 STCW 95 Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7604056
1 October 2021 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7324393
16 September 2020 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7059621
28 March 2019 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6650941
29 January 2019 NPV Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6616472
5 April 2018 NPV Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6390012
30 November 2016 Deficiency Check · NPV Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6048968

Deficiency record · 43

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 January 2026 Resolved
During a Port State Control (PSC) examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified an active, pressurized lubricating oil leak at the flanged connection of the main propulsion engine oil cooler. The leak has resulted in a significant accumulation of viscous oil and sludge on the engine block and cooling system piping. Pursuant to 46 CFR § 90.05-1, this vessel is subject to the applicable standards of 46 CFR Subchapter F (Marine Engineering). The current material condition of the propulsion machinery fails to meet the standards for design and workmanship established in 46 CFR § 58.05-1, which requires propulsion machinery to be equivalent to American Bureau of Shipping (ABS) rules. Specifically, the failure of a pressure-side sealing element in a vital system violates the requirement for machinery to be maintained in a safe, efficient operating condition. This condition constitutes an immediate fire hazard under 46 CFR § 92.05-1 due to the proximity of flammable oil to high-temperature exhaust surfaces. Furthermore, the uncontrolled discharge of oil into the machinery space bilges is a violation of 33 CFR § 155.770. 46 CFR § 58.05-1 Code 17(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2026
Resolved 20 May 2026
Resolution: The FSM surveyor approved the repair. PSCO witnessed operation of the engine with no oil leaks observed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 January 2026 Resolved
During a Port State Control examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified that the engine room bilge suction piping (red pipe) lacks a required strainer at the suction terminus. Pursuant to 46 CFR § 90.05-1, this cargo vessel is required to comply with the engineering standards of 46 CFR Subchapter F. Specifically, 46 CFR § 56.50-50(g) mandates that 'each individual bilge suction shall be fitted with a suitable bilge strainer having an open area of not less than three times at of the suction pipe. The current arrangement, which lacks any form of suction protection, allows for the ingestion of solids into the piping system. This constitutes a failure to maintain a vital dewatering system in an efficient operating condition and creates a significant risk of pump failure during emergency operations due to debris ingestion. 46 CFR § 56.50-50(g) 17(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2026
Resolved 20 May 2026
Resolution: The FSM surveyor approved the repair.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 January 2026 Resolved
During a Port State Control examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified that the vessel's installed fire main system is not being maintained in an appropriate condition for service. Specifically, a significant seawater leak was observed at the housing of the independent fire pump sea suction strainer, resulting in standing water on the engine room deck. Pursuant to 46 CFR § 90.05-1, this vessel must meet the fire protection standards of Subchapter I. The current condition violates 46 CFR § 95.10-5(a), which requires an installed firemain system appropriate for the vessel's service. A leak on the suction side of an emergency pump compromises system reliability and the vessel's primary firefighting capability. Furthermore, under the engineering standards of Subchapter F incorporated by reference, the failure to maintain a leak-tight pressure boundary violates 46 CFR § 58.01-5, which requires all vital machinery and associated fittings to be maintained in an efficient operating condition. 46 CFR § 95.10-5(a) 17(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2026
Resolved 20 May 2026
Resolution: The FSM surveyor approved the repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2026 Resolved
During a Port State Control examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified that the vessel's power-operated steering gear system is missing required rudder stops. Pursuant to 46 CFR § 90.05-1, this vessel is subject to the engineering standards of 46 CFR Subchapter F. Specifically, 46 CFR § 58.25-50(b) mandates that 'strong and effective structural rudder stops must be fitted' unless adequate positive stops are provided within the steering gear itself. The current absence of these stops poses a direct threat to the mechanical integrity of the rudder stock and the steering gear assembly, as there is no physical means to limit rudder travel and prevent structural over-stressing. 46 CFR § 58.25-50(b) 17(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2026
Resolved 20 May 2026
Resolution: The FSM surveyor approved the repair.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 January 2026 Resolved
During a Port State Control examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified that the starboard side fire hose valve is in a degraded and inoperable condition. The valve is mechanically stuck in a partially open position, preventing full water flow to the hose station. Pursuant to 46 CFR § 90.05-1, this vessel is subject to the fire protection standards of Subchapter I. The current condition violates 46 CFR § 95.10-5(a), which requires an installed firemain system appropriate for the vessel's service. Testing revealed the starboard hose station could only produce roughly half the pressure of the port station ({27.5} psi vs {55} psi), rendering the station ineffective for firefighting operations. Furthermore, the valve fails to meet the serviceability requirements of 46 CFR § 58.01-5 for vital auxiliary systems. 46 CFR § 95.10-5(a) 17(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2026
Resolved 20 May 2026
Resolution: The FSM surveyor approved the repair. PSCO witnessed operation of the fire hose and fire pump. The port side hose was found leaking and was addressed in a new deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 January 2026 Resolved
During a Port State Control examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified that the vessel’s inflatable life raft has not been serviced since 2023. Pursuant to 46 CFR § 91.25-15, life-saving appliances must be inspected to ensure they are in a serviceable condition and meet the requirements of Subchapter W. This vessel fails to meet the specific technical mandate of 46 CFR § 199.45(b)(4), which requires that each inflatable life raft be serviced at intervals not exceeding 12 months. The presence of expired primary life-saving equipment constitutes a major non-conformity and a significant risk to the safety of the crew. 46 CFR § 199.45(b)(4) 17(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2026
Resolved 20 May 2026
Resolution: The FSM surveyor approved the repair. PSCO verified the new life raft onboard is in a new condition with the appropriate inspection endorsements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 January 2026 Resolved
During a Port State Control examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified that the port main engine jacket water temperature gauge located at the helm station is inoperable. Pursuant to 46 CFR § 90.05-1, this vessel must adhere to the engineering standards of 46 CFR Subchapter F. Specifically, 46 CFR § 58.05-1, the arrangement of propulsion machinery must be equivalent to ABS Steel Vessel Rules, which require that essential parameters for the safe operation of the engines be monitored from the maneuvering station. The failure of this gauge deprives the operator of critical data necessary to prevent catastrophic engine failure and associated fire hazards. 46 CFR § 58.05-1 50(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 February 2026
Resolved 1 July 2026
Resolution: The FSM surveyor approved the repair. PSCO witnessed operation
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 January 2026 Resolved
During a Port State Control examination conducted under the authority of 46 CFR § 2.01-13, the attending inspector identified multiple failures in the vessel's weathertight and watertight closures. Pursuant to 46 CFR § 90.05-1, the vessel must be maintained in a safe condition. The following conditions represent a failure to meet the general safety and maintenance standards of 46 CFR § 91.25-10: Gaskets: The aft weathertight door leading to the crew space and the forward port hole window were found with damaged and improperly fitted gaskets, compromising the weathertight integrity of the superstructure. Hatch Fastenings: The watertight hatch openings for Void 2 and Void 3 each have one broken threaded pin previously welded to the deck and used to secure the watertight hatch. Per the requirements of 46 CFR § 91.25-10, the inspector must be satisfied that the hull and its closures are in a 'serviceable condition.' The current state of these gaskets and broken dogging pins prevents a uniform seal, posing an unacceptable risk of progressive flooding or water ingress during heavy weather. 46 CFR § 91.25-10 17(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2026
Resolved 1 July 2026
Resolution: The FSM surveyor approved the repair. PSCO witnessed operation
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 16 September 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 16 September 2020 Resolved
No medical certificates for Master. STCW 95 Reg I/9
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2020 Resolved
Starboard propulsion is not suitable for vessels service and route. Reduction gear exhibit slippage when oil temperature is in normal operation temperature. 46CFR58.10-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 September 2020 Resolved
Watertight hatch to steering compartment has severe material wastage around gasket. 46CFR42.15-35
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 September 2020 Resolved
Aft watertight door for crew space is not weathertight. Door gasket is not fully seated allowing water to leak by. 46CFR42.15-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2020 Resolved
Mast light, search light and anchor light are not operational. 72COLREGS
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 16 September 2020 Resolved
Rudder indicator in steering compartment is wasted and unreadable. 46CFR58.25-24
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 September 2020 Resolved
Salt water piping to Generator heat exchanger has temporary repair patch installed. Remove temporary patch and make permanent repairs.46 CFR 58.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2020 Resolved
Missing light and whistle on life jackets. 46CFR199.70(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 September 2020 Resolved
Fire detection system for engine room is not operational. 46CFR95.05-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 September 2020 Resolved
Annual service for Fixed fire extinguisher in engine room has expired. Crew are not familiar with procedures for system testing. 46CFR95.05-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 September 2020 Resolved
Fire pump (1) & (2) wee not opertional. 46CFR95.10-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 September 2020 Resolved
Visual and audible bilge high level alarm for #3 void is not operational. 46CFR62.35-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2020
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 September 2020 Resolved
Starboard rudder post has steady salt water leak through post packing gland. 46CFR42.15-30
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 September 2020 Resolved
Salt water leaking through Generator's salt water pump. 46 CFR 58.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 September 2020 Resolved
The vessel has no records of crew training or drills such as fire and abandon ship, ect. 46 CFR 97.35 & 46 CFR 97.15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 September 2020 Resolved
Improper bulkhead penetration aft engine room bulkhead. Bulkhead penetration in machinery space must be fire proof and water tight using stuffing tubes. 46CFR56.50-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 September 2020 Resolved
Remote shutoff valve for fuel tanks are not operational. 46CFR56.50-75
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 September 2020 Resolved
Exhaust gas leaking from generator exhaust pipe. 46CFR58.10-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2020
Resolved 30 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2019 Resolved
Vessel's propulsion must meet class requirement. VSL STBD engine sustained casualty to main bearing. Conduct repairs IAW engine manufacture procedures and provide Coast Guard approval letter from Flag State.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 January 2019 Resolved
VSL only generator is out of commission. VSL required power source adequate for maximum electrical loads. Conduct repairs and load test IAW manufacture instruction to the satisfaction of the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 January 2019 Resolved
Starboard propulsion engine and generator are not suitable for vessels service and route. Major exhaust leak on starboard propulsion engine aft of turbocharger. Exhaust pipe for generator wasted, disconnected between engine room ceiling and stack space. Repair both exhaust leak to the satisfaction of the attending MI. 46CFR58.10-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 29 January 2019 Resolved
Vessel does not meet watertight condition for machinery space. Wasted & holed port blower housing for engine room, allowing salt water to enter engine room. In addition, exhaust blower is out of commission. Conduct repairs to blower housing and blower motor to the satisfaction of the attending Coast guard Marine Inspector. 46CFR15-35
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 January 2019 Resolved
Forward engine room escape hatch locking mechanism is inoperable. Conduct repair to water tight hatch and show proper hatch operation to the attending Coast Guard Marine Inspector. 46CFR42.15-35
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 January 2019 Resolved
Hydraulic system for forward ramp is out of commission and not suitable for vessels service. Conduct repairs IAW equipment manufacture instruction and demonstrate proper ramp operation to attending Coast guard Marine inspector. 46CFR58.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2019
Personnel › Certificates/Documents/Licenses › License, Master
Issued 5 April 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 19 April 2018
Resolved 19 April 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 April 2018 Resolved
Fixed fire extinguisher must be serviced annually as required by 46 CFR 97.15-60. Provide proof of annual service for FFEG.
Due 19 April 2018
Resolved 19 April 2018
Lifesaving › Lifebuoys › Serviceable
Issued 5 April 2018 Resolved
All life saving equipments must be in serviceable codncitions as required by 46 CFR 199.70. Replace deteriorate lifebouys.
Due 19 April 2018
Resolved 19 April 2018
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 April 2018 Resolved
Electrical equipment must be protected from wet and corrosive environment as required by 46 CFR 90.25. Repair wasted junction box on starboard deck for engine exhaust blower.
Due 19 April 2018
Resolved 19 April 2018
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 April 2018 Resolved
Electrical equipment must be protected from wet and corrosive environment as required by 46 CFR 90.25. Install missing electrical outlet on main deck.
Due 19 April 2018
Resolved 19 April 2018
Lifesaving › Inflatable Liferafts › Servicing
Issued 5 April 2018 Resolved
Life raft must be serviced annual as required by 46 CFR 199.175. Provide proof of annual service on life raft.
Due 19 April 2018
Resolved 19 April 2018
Fire Fighting › Fire Main › Pressure
Issued 27 January 2017 Resolved
Found seized pressure gauges at port & STBD fire stations. Replace inoperable pressure gauges.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 7 February 2017
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 30 November 2016 Resolved
When port & STBD propulsion engines are clutched-in and placed in synchronize mode, the RPM of the slave engine is not in sync with the RPM of the master engine. Conduct repairs IAW engines manufacture instructions.
Due 27 February 2017
Resolved 27 February 2017
Personnel › Manning/Qualifications › Medical Fitness
Issued 30 November 2016 Resolved
Two of the crew have expired medical certificates. Provide valid medical certificates for the crew. ILO 47 & CONDTINST 16711.12.
Due 27 February 2017
Resolved 27 February 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 November 2016 Resolved
Hydraulic motor for steering system will trip-off line when the motor for cargo ramp winch is energized. Conduct survey on the electrical equipments, make repairs, and conduct test to the satisfaction of the attending Coast Guard Marine inspector.
Due 27 February 2017
Resolved 27 February 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.