← All vessels
MSC CARMEN
Freight Ship · General Dry Cargo Ship class · Built 2000s · USCG East District (CGD-E) · Other hulls named MSC CARMEN
MSC CARMEN is a 2008 freight ship. The Coast Guard has recorded 18 inspections since 2015, most recently in August 2026, along with 10 deficiencies and 1 operational control.
Records from 2015 to 2026. Most recent: inspection, 4 August 2026.
- Built
- 2008
- Last inspected
- 4 August 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9349813 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EQT
1231272
Flag
PANAMA
—
Maury page id
psix-1231272
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it50963 - Convention (Subpart B), Gross Ton
30224 - Convention (Subpart B), Net Ton
82672 - Displacement, Ton
63359 - Dead Weight, Ton
30224 - Convention (Subpart B), Net Ton
82672 - Displacement, Ton
63359 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
4 August 2026
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8453489
10 January 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8293905
26 June 2025
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8167845
22 June 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8164097
10 August 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7975639
5 June 2024
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7928973
28 May 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7921439
23 February 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7868896
11 August 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7774176
8 August 2023
PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7762542
14 November 2019
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6855560
15 October 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6832259
4 September 2017
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6259051
17 July 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6211785
11 July 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5937063
19 August 2015
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5220351
11 August 2015
Administrative Inspection · ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5206696
10 August 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5211723
Deficiency record · 10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2025
Resolved
Atleast two independent means shall be provided for communicating orders from the navigation bridge to the position in the machinery space... One of these shall be an engine-room telegraph which provides visual indication of the orders and responses both in the engine room and on the navigation bridge. Master notified PSCO of inoperable bridge main engine telegragph.
74SOLAS(04)II-I/37.2
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 June 2024
Resolved
A fixed pressure water-spraying fire-extinguishing system complying with the provisions of the fire safety systems code. 74 SOLAS (20) II-2/10.4.1.1.3
Any required automatic sprinkler... shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. Vessel reported water mist system only works in local control. FSS Code 8.2.5.1.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 May 2024
Resolved
A fixed pressure water-spraying fire-extinguishing system complying with the provisions of the fire safety systems code. 74 SOLAS (20) II-2/10.4.1.1.3
Any required automatic sprinkler... shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. Vessel reported water mist system only works in local control. FSS Code 8.2.5.1.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019
Resolved
The date when musters are held, details of abandon ship drills and fire drills, drills of other life-saving appliances and on board training shall be recorded. Details of drills conducted were not being recorded. 50ac
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019
Resolved
Each transfer pipe system must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. The frequency of the tests and inspections required by this section must be, for vessels, annually. Vessel has conducted pressure test using air. Vessel is not allowed to bunker in the United States.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 July 2017
Resolved
0750-Fire resisting divisions shall be kept in good order so as to ensure their required performance if a fire occurs. A60 Heat shielding in emergency steering torn and not protecting boundary. 74 SOLAS (2014 CONS) II-2/14.2.1.1
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 July 2017
Resolved
0925-Enclosed space entry and rescue drills should be planned and conducted in a safe manner and shall be given with regular intervals of instructions in the use of the ship's lifesaving and fire extinguishing appliances every two months. Vessel has not conducted an enclosed space drill since 21JAN17. 74SOLAS(2014 CONS) iii/19.3.6
Operations/Management › Pollution › Retention of Oily Mixture
Issued 17 July 2017
Resolved
0999-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regs to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Excessive oily liquid build up in emergency steering gear room. 74SOLAS(2014 CONS) 1/11
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump
Issued 11 August 2015
Resolved
0725- fixed fire extinguishing installation- Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The local fixed water mist/fog system was found in the "off" position rendering the system incapable of being started automatically and from a remote position. 74SOLAS(04) II-2/14.2.1.2
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pressure
Issued 11 August 2015
Resolved
0725- fixed fire extinguishing installation- Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The local fixed water mist/fog system has a low water level and pump faults. 74SOLAS(04)II-2/14.2.1.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.