Inspection history · 5
6 December 2021
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7363018
25 October 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7336347
13 September 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5996287
13 September 2016
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6000215
13 September 2016
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6001782
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2021
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. Following a Captain of The Port (0579-21) order, PSCO conducted damage survey following propulsion irregularity. Observed start air compressor (model #:WP 271 L) operation and a low start air alarm (@1.79 bars) on the alarm history log in engine control room. Provide concurrence from Class Society to attest that system is operation properly. 74 SOLAS (20) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Due 6 December 2021
Resolved 7 December 2021
Resolution: Reviewed and accepted class report from Korean Register, CoTP order cleared.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 October 2021
Resolved
The following Fire Protection Systems shall be kept in good order so as to ensure their required performance if a fire occurs: Fire detection and fire alarm systems. PSCO observed failure of smoke detector over incinerator to operate during test. Crew records state detectors tested 10/24/21.
07106, Fire Detection and alarm system, 74 SOLAS (AM) II-2 / 14.2.1.2, 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2021
Resolution: Received, reviewed and accepted Class Report from [name withheld] stating the smoke detector above the incinerator was replaced and tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 October 2021
Resolved
The fixed fire detection and fire alarm system required in paragraph 4.1.1 shall be so designed and the detectors so positioned as to detect rapidly the onset of fire in any part of those spaces and under any normal conditions. PSCO witnessed bag secured over smoke detector located over boiler cascade tank. Chief engineer stated due to steam from cascade tank creating false alarms, crew covers detector. Request verification from the certificate issuing authority of the covering of the detector as allowable procedure.
07106 Fire Detection and alarm system, 74 SOLAS (AM) II-2/7.4.2, 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2021
Resolution: Received, reviewed and accepted Class and ISM Audit Report from [name withheld] stating the bag removed from smoke detector. Smoke detector and cascade tank alarms tested all sat. Procedures reviewed with crew to the operation and covering of the tank.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 October 2021
Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the relevant rules and regulations and any additional requirements which may be established by the company. As noted in deficiencies 01 & 02 the PSCO believes there is objective evidence that the ship is not being maintained oroperated as required in relation to fire figthing systems/maintenance. Request ISM audit be conducted by the certificate issuing authority within 90 days.
15109 Maintenance of the ship and equipment,
74SOLAS(20)IX/3.1, ISM Code Chapter 10.1, C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2021
Resolution: Received, reviewed and accepted ISM Audit Report from [name withheld] stating the deficiencies and maintenance record keeping and testing of fire detection/suppresion was rectified.