Records from 1991 to 2025. Most recent: inspection, 29 September 2025.
Inspection history · 62
29 September 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8243210
29 September 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8247161
20 August 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8257230
14 May 2025
Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8136140
2 May 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8160231
1 August 2024
COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7948132
20 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7827891
28 September 2021
Polar Code Examination · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7322122
13 November 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7124120
1 October 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7069098
21 November 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6860092
24 July 2019
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6760710
29 July 2015
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5205689
8 February 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4800015
26 November 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4762152
13 December 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4501743
26 October 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4474725
20 March 2012
MTSA Verification · DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4273230
21 July 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4138294
20 May 2011
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4021892
11 August 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3876913
24 February 2010
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3686479
27 August 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3581692
22 April 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3189526
11 December 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3115565
22 September 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3063581
21 September 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3062968
21 September 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3071232
11 March 2006
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 2606567
3 February 2006
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2578568
3 February 2006
Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2578849
30 January 2006
Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2576139
30 January 2006
Damage Survey
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2576140
21 December 2005
MTSA Verification · Uninspected Other
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2561583
4 July 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2419817
28 June 2004
MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2113479
12 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980783
21 November 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1953156
3 April 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1768269
27 September 2002
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1683759
14 August 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1661384
12 August 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1660070
24 July 2002
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1804090
12 December 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1474851
19 November 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 84322
6 November 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 159171
28 December 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 84942
25 September 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 210580
25 September 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 756479
19 September 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 30356
17 September 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 8995
2 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 136732
26 March 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 57330
17 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 110568
11 June 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 83283
13 December 1997
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 20411
2 February 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 126527
17 September 1995
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 383031
24 February 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 667688
10 February 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 375559
22 May 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 367358
29 June 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 229065
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 September 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. VSL report a clutch fire on their port clutch. VSL shall proceed to port to effect repairs on unaffected engine, VSl shall not engage in any towing operations in transit.
46 CFR 143.205 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 September 2025
Resolved
Towing vessels of more than 65 feet in length must carry—(1) At least the minimum number of portable fire extinguishers set forth in table 142.230(b); and(2) One 40-B portable fire extinguisher fitted in the engine room for each 1,000 brake horsepower of the main engines or fraction thereof. A towing vessel is not required to carry more than six additional 40-B portable fire extinguishers in the engine room for this purpose, regardless of horsepower. VSl expended 02 portable fire extinguishers.
46 CFR 142.230 (b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems must be maintained to ensure proper operation. The vessel's generator was inoperable due to clogged filter causing loss of steering.
46 CFR 143.205(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2025
Resolution: Accepted as condition of class & closed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2025
Resolved
A vessel owner, charterer, managing operator or agent shall immediately notify either of the following Coast Guard officers if there is reason to believe a vessel is lost or imperiled. Vessel notified the Coast Guard 12 days after the incident occurred.
46 CFR 4.04-1
Action required: 10 - Deficiency Rectified
Resolved 14 May 2025
Resolution: CG was notified.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 28 September 2021
Resolved
Vessel does not have Long Range Identification and Tracking of ships (LRIT) capability. Prior to vessel's next international voyage, install LRIT IAW 74 SOLAS (14) V/19-1.4.1
Action required: 702 - Prior to embarking on international voyage
Resolved 25 October 2021
Resolution: Verified LRIT report.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 28 September 2021
Resolved
Vessel does not have bunker notes onboard along with fuel samples. As discussed with operator, vessel will be bunkering before next international voyage. Before next international voyage, obtain and carry onboard bunker notes and bunker samples. MARPOL Annex VI, Reg 18.6
& MARPOL Annex VI, Reg 18.8.1
Action required: 702 - Prior to embarking on international voyage
Resolved 25 October 2021
Resolution: Moving forward, bunker delivery notes will be maintained.
01 - Certificates & Documentation › 013 - Documents › Ship Energy Efficiency Management plan
Issued 28 September 2021
Resolved
Vessel shall develop Ship Energy Efficiency Management Plan (SEEMP). MARPOL Annex VI, Reg 22
Action required: 702 - Prior to embarking on international voyage
Resolved 25 October 2021
Resolution: SEEMP verified.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 28 September 2021
Resolved
Vessel shall amend Garbage Management Plan and have updated placards to reflect polar operation. MARPOL Annex V, Reg 10
Polar Code II-A/5.2.3
Action required: 702 - Prior to embarking on international voyage
Resolved 25 October 2021
Resolution: Verified updated placards.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 November 2019
Resolved
Except as provided by 15.725 of this part, no vessel may be navigated unless it has in its service and onboard the crew compliment required by the COI. It was reported that the vessel is sailing with out an Able Seamen or Ordinary Seamen with a proper credential to serve as rating forming part of a navigational watch. Provide the required crew complement required by the vessel's COI at the first port after departure from Midway Island, USA.
Action required: 705 - Other - as specified
Resolved 30 September 2020
Resolution: Verified proper manning per the vessel's Certificate of Inspection. //s// [name withheld], LT
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 21 September 2007
Resolved
Vessel had a port main diesel engine fire which cause a brief loss of propulsion.
Action required: 705 - Other - as specified
Due 5 October 2007
Resolved 25 September 2007
Resolution: Received proper technician report attesting to repairs made to a faulty seal on vessel''s MDE turbo.
Construction/Loadline › Hull › Weld
Issued 30 January 2006
Resolved
Effect permanent repairs to cracked weld in deck in way of starboard mooring bit support framing to satisfaction of an attending ABS class surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 February 2006
Resolved 3 February 2006
Resolution: Recieved a satisfactory ABS class report this date attesting to repairs completed.
Engineering
Issued 10 February 1995
Resolved
VESSEL DID NOT HAVE ONBOARD ANY OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Accommodation/Occupational Safety
Issued 10 February 1995
Resolved
VESSEL'S MSD OVERBOARD DISCHARGE VALVE WAS IN THE OPEN POSITION ALLOWING RAW SEWAGE TO ENTER DIRECTLY INTO THE CAPE FEAR RIVER.
Condition: Unknown
Due 10 February 1995
Resolved 24 February 1995
Lifesaving
Issued 10 February 1995
Resolved
PFD'S MISSING REQUIRED LIGHTS.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Lifesaving
Issued 10 February 1995
Resolved
ALL FLARES ONBOARD VESSEL WERE EXPIRED.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995