CMA CGM LA TRAVIATA is a 2005 freight ship. The Coast Guard has recorded 23 inspections since 2017, most recently in June 2026, along with 5 deficiencies and 9 operational controls.
Records from 2017 to 2026. Most recent: inspection, 21 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it48921 - Convention (Subpart B), Net Ton 101811 - Dead Weight, Metric Ton 135530 - Displacement, Metric Ton 91410 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2026Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED THAT ELECTRICAL PANEL FOR "NO. 2 HFO PURIFIER" WAS BROKEN, AND UNABLE TO SECURE, EXPOSING HAZARDOUS ELECTRICAL EQUIPMENT.
SOLAS (04) II-1 / 40.1.3
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 June 2026
Resolved 21 June 2026
Resolution: CREW ABLE TO SECURE PANEL BEFORE PSC TEAM DEPARTED VESSEL
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2026Resolved
THE MACHINERY...SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUMM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED NO LOCK-OUT TAG-OUT MECHANISMS IN PLACE WHILE BOTH NO. 1 & NO. 2 LO PURIFIERS FOR M/E LEFT OPEN FOR MAINTENANCE.
SOLAS (04) II-1 / 26.1
10 C
Action required: 10 - Deficiency Rectified
Due 21 June 2026
Resolved 21 June 2026
Resolution: CREW COMPLETED LOCK-OUT TAG-OUT PROCEDURES FOR BOTH PURIFIERS. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 March 2026Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PRWIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS: PSCO OBSERVED FUEL OIL LEAKS FROM THE FUEL OIL TRANSFER PUMP FUEL OIL BOOSTER PUMP, INDICATOR FILTER IN PURIFIER ROOM, AND MAIN FUEL PIPE LINE. PSCO ALSO OBSERVED FUEL OIL LEAK IN THE LS HFO SETTL DRAIN.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2026
Resolution: Sector Houston/Galveston received satisfactory Class Report attesting to the issued deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 January 2025Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCE observed oil accumulation in the #1 and #2 induction motors adjacent to the Main Diesel Engine.
74SOLAS(04)II-2 4.1.1
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2025
Resolution: Received class report and photos showing oil accumulation was resolved.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 8 April 2022Resolved
33 CFR 164.40(a) vessel is to repair speed log and provide tech report prior to departure.
Action required: 10 - Deficiency Rectified
Due 8 April 2022
Resolved 13 April 2022
Resolution: Technician repaired ships speed log.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.