MAURY USCG vessel records Sign in
← All vessels

IKI

IKI is a 2005 freight ship. The Coast Guard has recorded 11 inspections since 2014, most recently in May 2020, along with 4 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 2014 to 2020. Most recent: inspection, 18 May 2020.

Built
2005
Last inspected
18 May 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9300881 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1232737
Flag
PANAMA
—
Maury page id
psix-1232737

Inspections, by type

…with no type recorded2
…past their stated due date1
Years with a record 6 calendar years (2014–2020)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13694 - Simplified, Gross Ton
6537 - Simplified, Net Ton
13694 - Convention (Subpart B), Gross Ton
6537 - Convention (Subpart B), Net Ton
20190 - Dead Weight, Ton
26126 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

18 May 2020 Deficiency Check · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6951073
17 May 2020 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6955465
14 August 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6774772
27 July 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6492591
24 January 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6342880
21 November 2016 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6045213
30 October 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6031963
16 October 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6022908
7 August 2015 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5206471
19 August 2014 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4959877
9 August 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4948686

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 May 2020 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. Port State control team ovserved a cardboard box covering flame detector above incinerator.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 19 May 2020
Resolution: RECEIVED CLASS REPORT CLEARING DEF.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 18 May 2020 Resolved
The condition of the ship and equipment shall be maintained to conform with the provisions of the present regulations...Port State inspectors found the incinerator's refractor wasted, along with associated V-shaped hooks missing, per manufactures standar. C/E has welded non-approved rebar. This disables the prevention of spreading of flame thus causing previoulsy mention alarm to activate.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 19 May 2020
Resolution: RECEIVED CLASS REPORT CLEARING DEF.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 18 May 2020 No resolution recorded
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. Multiple non-approved modifications were found on the steam line, boiler drain.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2020 — due date passed with no resolution recorded
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 9 August 2014 Resolved
The vessels charges were expired on all four line throwing appliances. (to the satisfaction of CG and Class)
Action required: 705 - Other - as specified
Due 23 August 2014
Resolved 19 August 2014
Resolution: Vessel provided proof of current charges for the line appliances.

Ownership record