BALTIC PROSPERITY

BALTIC PROSPERITY is a 2012 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in February 2026, along with 22 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 13 February 2026.

Built
2012
Last inspected
13 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9576820
1232798
Flag
CYPRUS
Maury page id
psix-1232798

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it18044 - Dead Weight, Metric Ton
23472 - Displacement, Metric Ton
11383 - Convention (Subpart B), Gross Ton
5590 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 11

13 February 2026 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8309267
13 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8295588
23 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8216206
5 June 2025 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8150990
17 April 2025 Appeal
Administrative · Commandant (CG-CVC) · Activity 8134932
18 February 2025 In-Service Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8079283
17 February 2025 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8080399
22 December 2023 PSC B · COC-CHEM & TVE Renew · Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7841073
9 February 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6082446
16 August 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5974408
14 January 2016 ISPS III Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5794763

Deficiency record · 22

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 February 2026 Resolved
The purpose of this regulation is to contain a fire in space or origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed the following “A” doors would not latch: 108, 134 and a hole in the “A” boundary bulkhead leading to steering gear room. Code 07105, 74 SOLAS (09) II-2/9.1.3, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 February 2026
Resolution: Ship's crew rectified the deficiency to the satisfaction of attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 February 2026 Resolved
Monthly inspections should be carried out to ensure that all fireman’s outfits, fire extinguishers, fire hydrants, hose and nozzles are in place, properly arranged, and are in proper condition. PSCO observed CO2 extinguisher #41 had not been inspected in over 2 months. Code 07110, 74 SOLAS (09) II-2/14.2.2.1; MSC/Circ.850, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 February 2026
Resolution: Ship's crew performed required monthly inspection to the satisfaction of attending PSCO.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 February 2025 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company.[10.1] The technical nature of the deficiencies listed below provide objective evidence of a serious failure of the implementation of the ISM Code, and an external audit of the vessel's SMS focusing on engine room maintenance, electrical maintenance and alterations, and fire boundaries and electrical runs is required. 74 SOLAS (20) IX/3.1 ISM Code 10.1 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 February 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel leaks on 4 of 7 fuel pumps on the Main Engine. 74 SOLAS (20) II-2/4.1.1 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 February 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a piece of wood jammed into the #1 cylinder head on the main engine. 74 SOLAS (20) I/11(a) 30ac
Condition: Improper Installation
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 February 2025 Resolved
Ships shall be designed constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the administration. PSCO observed multiple electrical panels with broken latches being tied shut and propped closed with metal piping. 74 SOLAS (20) II-1/3-1 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 February 2025 Resolved
The purpose of this regulation is to detect a fire in the space of origin and to provide for alarm for safe escape and fire-fighting activity. For this purpose, the following functional requirements shall be met: Fixed fire detection and fire alarm system installations shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. PSCO observed multiple faults on the vessel's fire detection system. 74 SOLAS (20) II-2/7.1.1 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 February 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. PSCO observed crew not having equipment to test temperature sensors on board. 74 SOLAS (20) II-2/14.1.2 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 February 2025 Resolved
Self-closing fire doors of the same fire integrity standards shall be fitted in the enclosure. PSCO observed warped A class doors that do not shut entirely. 74 SOLAS (20) II-2/13.4.1.1.1 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 19 February 2025 Resolved
Plans and booklets shall be kept up to date; any alterations thereto shall be recorded as soon as practicable. PSCO observed fire doors removed, piping alterations, and penetrations of bulkheads for electrical wiring that were not in accordance with on board fire control plan. 74 SOLAS (20) II-2/15.2.4.1 30ac
Condition: Improper Installation
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 February 2025 Resolved
The means for securing these doors weather-tight shall consist of gaskets and clamping devices or other equivalent means shall be permanently attached to the bulkhead or to the doors themselves, and the doors shall be so arranged that they can be operated from both sides of the bulkhead. PSCO observed weather-tight seals missing on multiple doors and vents. ICLL (88 Prot.) Reg 12(1) 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 February 2025 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed electrical conduit on deck corroded though in multiple areas exposing wiring. 74 SOLAS (20) II-1/45.11 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2025 Resolved
A fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. PSCO observed fixed storage tank with insufficient supply of hydraulic fluid. 74 SOLAS (20) II-1/29.12.3 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 February 2025 Resolved
The system shall be capable of discharging through fixed discharge outlets a quantity of foam sufficient to produce an effective foam blanket over the largest single area over which fuel oil is liable to spread. PSCO observed low expansion foam tank gauging in-operable. 74 SOLAS (20) II-2/10.8.1.3 FSS 6.4.1.2 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 February 2025 Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be: Painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter (0.33 foot) and the width of the middle yellow band must be 0.8 meter (2.64 feet); and Labeled with the word “VAPOR” painted in black letters at least 50.8 millimeters (2 inches) high. PSCO observed all vapor piping incorrectly marked. 46 CFR 39.2001(h) 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 28 February 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 December 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The objective evidence of the deficiencies below brings into question the validity of the Safety Management System as required in the International Safety Management Code. An external audit is required to be submitted to the Coast Guard. 74SOLAS 20 IX/3.1 ISM CODE Part A/10.1
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2023
Resolved 24 December 2023
Resolution: Accepted external audit.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 22 December 2023 Resolved
Tankers shall be equipped with at least one portable instrument for measuring flammable vapor concentrations, together with a sufficient set of spares. Suitable means shall be provided for the calibration of such instruments. The vessel does not have the appropriate span gas on board to calibrate it's portable gas detectors. 74SOLAS 09 II-2/4.5.7.1
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2023
Resolved 24 December 2023
Resolution: Vessel acquired span gas. Conducted calibration of portable gas detector. Sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 December 2023 Resolved
Ships shall be maintained in compliance with the structural requirements of the Class Society which is recognized by the Administration. The hatchway of cargo tank four (04) starboard was found to be leaking inert gas / cargo vapors. 74 SOLAS 20 II-1/3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2023
Resolved 24 December 2023
Resolution: Replaced gasket, no more leak observed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 December 2023 Resolved
Tankers of less than 20,000 tons dead-weight shall be provided with a deck foam fire-extinguishing system complying with the requirements of the Fire Safety Systems Code. The vessel's most forward foam monitor was leaking water from 02 fittings on the main body and as a result was unable to provide sufficient pressure to throw 15 meters in still conditions as required by the Code. 74 SOLAS 09 II-2 10.8.1.3 FSS CODE 14.2.2.2.2
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2023
Resolved 24 December 2023
Resolution: Repaired foam monitor and PSCO observed adequate stream of water.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 December 2023 Resolved
All life-saving appliances shall be in working order and ready for immediate use. Rescue boat steering was found not able to steer to port, therefore unable to satisfactorily maneuver the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2023
Resolved 24 December 2023
Resolution: Steering was repaired.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 22 December 2023 Resolved
If during a voyage any equipment required by this part stops operating properly, the person directing the movement of the vessel may continue to the next port of call, subject to the directions of District Commander or the Captain of the Port. The vessel did not notified the Coast Guard of it's inoperable speed log and has not requested a Deviation From the Rules. Request an outbound Letter of Deviation and comply with any vessel movement restrictions that the Captain of the Port may impose. 33CFR 164.53(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2023
Resolved 24 December 2023
Resolution: Sat.
Engineering › Steering Gear System › Feedback Unit
Issued 14 January 2016 Resolved
1510-Navigation Equipment-The condition of the ship's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. During steering gear test, PSCO observed the rudder to be hunting at amidships when under bridge control on pump no. 1, system no. 1 follow up mode. SOLAS (am) I/11(a)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2016
Resolved 15 January 2016
Resolution: Recieved tech report that the technician adjusted the dead band settings and the rudder feedback alignment.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.