MAURY USCG vessel records
← All vessels

FAITH

FAITH is a 2012 freight ship. The Coast Guard has recorded 12 inspections since 2017, most recently in September 2024, along with 5 deficiencies and 5 operational controls.

Records from 2017 to 2024. Most recent: operational control imposed, 25 September 2024.

Built
2012
Last inspected
25 September 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 September 2024
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9497529
1232872
Flag
LIBERIA
Maury page id
psix-1232872

Documentation record

Tonnage as PSIX records it37763 - Displacement, Metric Ton
30036 - Dead Weight, Metric Ton
18722 - Convention (Subpart B), Gross Ton
9991 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

25 September 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8008578
25 September 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8009445
28 June 2023 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7725757
23 June 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7714830
22 June 2023 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7720913
20 June 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7719220
4 August 2022 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7524720
27 May 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7460631
17 September 2021 Deficiency Check · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7314312
1 May 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7186813
1 June 2017 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6134792
11 May 2017 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6134762

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 June 2023 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met. Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO Observed both CO2 bottles for paint locker not able to be activated due to handles being seized with excessive corrosion. Inspect System to ensure all components are working properly. SOLAS (74) 2004 11-2/14.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2023
Resolution: Vessel provided flag state inspection report and technician report attesting to repairs.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 17 September 2021 Resolved
Any main and auxiliary steering gear control system operable from the navigation birdge shall be in the event of a failure of electrical power suply to the control system, an audible and visual alarm shall be given on the navigation bridge. Audible and visual alarm was not able to be activated on the bridge. 74 SOLAS (2004) II-1 Regulation 29.8.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 September 2021 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed hold-back hook on self-closing door to fire locker. 74 SOLAS (2009) II-2 Regulation 9.4.2.2
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2021
Resolved 27 September 2021
Resolution: Received Bureau Veritas Report of Survey attesting to crew removal of holdback hook and door being free to self-close.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 September 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed that the paint locker CO2 system manifold supply valve access box was locked and the access key was not immediately available. 74 SOLAS (2009) II-2 Regulation 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2021 Resolved
The machinery associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed leak on technical water pump #1 and valve on cargo bilge pipe. 74 SOLAS (2004) II-1 Regulation 26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 17 September 2021

Ownership record