Records from 1985 to 2021. Most recent: inspection, 1 January 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 37
1 January 2021
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7120156
18 July 2011
Administrative Inspection
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 4086437
20 January 2009
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3397179
26 September 2008
Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3333234
30 October 2007
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3090165
3 October 2006
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2792895
13 July 2006
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2711604
1 February 2006
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2577786
13 September 2005
Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2492398
7 May 2002
Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1614260
9 March 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1391506
22 February 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1430829
28 June 1999
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1090121
22 April 1999
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1125907
10 March 1999
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1375676
30 March 1998
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1123357
30 March 1998
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1364659
5 June 1997
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1406127
11 May 1997
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1406126
9 April 1996
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1357542
27 March 1996
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1357543
13 March 1995
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1357055
7 March 1995
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 864150
6 April 1994
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1436854
29 March 1993
Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1142672
16 March 1992
COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 956781
12 March 1991
COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1224442
16 March 1990
COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 901868
21 February 1989
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1351527
26 January 1988
Hull Examination · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1020473
5 May 1987
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1017975
16 February 1987
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1328618
11 February 1987
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1021803
11 February 1987
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1021964
24 February 1986
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 989101
26 July 1985
Credit Drydock
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1294416
7 March 1985
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1288182
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 September 2008
Resolved
Provide crane certification as per 46 CFR 107.258.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2009
Construction/Loadline › Structures › Deck Plating
Issued 7 June 2006
Resolved
Renew all of main cargo deck due to wastage.
Action required: 705 - Other - as specified
Resolved 7 June 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 June 2006
Resolved
Provide an ammeter for the generator.
Due 7 July 2006
Resolved 3 October 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 June 2006
Resolved
Provide guards for rotating hazards in engine room over both shafts.
Due 7 July 2006
Resolved 13 June 2006
Fire Fighting › Firemans Outfit › Axe
Issued 7 June 2006
Resolved
Provide a fire ax.
Due 7 July 2006
Resolved 13 June 2006
Electrical › Lighting (service) › Conductor
Issued 7 June 2006
Resolved
Remove clamp on light in cabin that is hard wired with zip cord.
Condition: Placed in Improper Service
Due 7 July 2006
Resolved 13 June 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 June 2006
Resolved
Remove gasoline container that is being used for water in cabin and if needed replace with proper potable water storage.
Due 7 July 2006
Resolved 13 June 2006
Construction/Loadline › Structures › Door
Issued 6 June 2006
Resolved
Service cargo deck water-tight door. Due to wastage and irregular bent surface, frame will not seal against new gasket.
Due 8 June 2006
Resolved 13 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 June 2006
Resolved
Service all portable fire extinguishers.
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 13 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 6 June 2006
Resolved
Provide appropriate marine brackets for portable fire extinguishers at "Stations" and number stations in 1/2" lettering.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 13 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 June 2006
Resolved
Remove wiring for load that is directly attached to the batteries bypassing the breaker panels - identified with inline fuses.
Due 6 July 2006
Resolved 13 June 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 June 2006
Resolved
Provide a magnetic compass in accordance with 46CFR122.402
Condition: Unknown
Due 6 July 2006
Resolved 13 June 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 June 2006
Resolved
Provide 100' line in accordance with 46CFR199.70(a)(3)(A) for the life ring buoy.
Due 8 June 2006
Resolved 13 June 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 June 2006
Resolved
Provide a second life ring buoy in accordance with 46CFR199.70 and place floating water light on this life ring.
Due 8 June 2006
Resolved 13 June 2006
Lifesaving › Lifebuoys › Stowage
Issued 6 June 2006
Resolved
Stow one life ring aft and one forward and mark stowage location with either the words "LIFEBUOY", or "LIFE BUOY", or with the appropriate symbol from IMO Resolution A.760(18).
Due 8 June 2006
Resolved 13 June 2006
Navigation › Piloting/Steering › Marine Charts
Issued 6 June 2006
Resolved
Correct charts (average age over 25 years) or provide newer more currently corrected charts for area of operation.
Condition: Improper/Lack of Maintenance
Due 8 June 2006
Resolved 13 June 2006
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 June 2006
Resolved
Provide draft marks.
Due 6 July 2006
Resolved 3 October 2006
Construction/Loadline › Hull › Strut/Cross Tie
Issued 7 May 2002
Resolved
Crop and Renew Aft deck stanchions in center void due to wastage/knife edging at lower ends, three on port side LEGACY COMPONENT DESC: Stanchions
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 2 March 2006
Construction/Loadline › Hull › Stiffener
Issued 7 May 2002
Resolved
Crop and renew the transverse deck stiffener on centerline, aft of hatch in forward center void. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 2 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 7 May 2002
Resolved
Crop and renew the main cargo deck, inboard of last deck/side shell renewals, due to deformation coupled with wastage. Or, prove that more than required minimum scantlings remain for deck strength. Ultrasonic gaugings will be acceptable to prove plate thickness. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 2 March 2006
Resolution: Rewritten to encompass all of the main cargo deck.
Construction/Loadline › Hull › Transverse Frame
Issued 7 May 2002
Resolved
Crop and renew both of the transverse deck stiffener on centerline, aft of hatch in center void #2.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 2 March 2006
Construction/Loadline › Hull › Stiffener
Issued 7 May 2002
Resolved
Replace two missing plate stiffeners on aft transverse watertight bulkhead in center void #2
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 2 March 2006
Construction/Loadline › Hull › Weld
Issued 7 May 2002
Resolved
Pick up weld where missing in Stbd void #2 at inboard lower corner of watertight bulkhead between #2 & #3. LEGACY COMPONENT DESC: Transverse watertight bulkhead in double sides
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 22 May 2006
Construction/Loadline › Hull › Weld
Issued 7 May 2002
Resolved
Pick up weld where missing in Stbd void #2 at outboard lower corner of watertight bulkhead between #1 & #2. LEGACY COMPONENT DESC: Transverse watertight bulkhead in double sides
Condition: Improper Installation
Due 11 May 2002
Resolved 22 May 2006
Construction/Loadline › Hull › Weld
Issued 7 May 2002
Resolved
Pick up weld where missing in port void #3 at area of flame discoloration at bottom of watertight bulkhead between voids #2 & #3. LEGACY COMPONENT DESC: Transverse watertight bulkhead in double sides
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 22 May 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 May 2002
Resolved
Provide proper fittings to penetrate watertight bulkhead between engine room and main cargo deck (open deck) where hydraulic lines penetrate bulkhead rendering bulkhead not watertight. LEGACY COMPONENT DESC: Forward Engine room water tight bulkhead
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 1 May 2006
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 May 2002
Resolved
Insert improper vents in watertight bulkhead between engine room and cargo deck (open deck) which renders watertight bulkhead not watertight. (Engine room has proper ventilation through goosenecks on main deck.) LEGACY COMPONENT DESC: Improper vents
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 1 May 2006
Construction/Loadline › Penetrations › Weld
Issued 7 May 2002
Resolved
Remove improper ventilation penetrations in aft engine room watertight bulkhead between engine room and lazerette. Weld in inserts and provide proper ventilation through goose necks installed on main deck. LEGACY COMPONENT DESC: Transverse watertight bulkhead
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2002
Resolved 1 May 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 7 May 2002
Resolved
Provide steel hatch in main deck between engine room and control space. Providing an A-15 hatch in A-60 deck. Installed hatch is made of wood. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 22 May 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 7 May 2002
Resolved
Provide welded insert in hole in main deck between engine room and control space where carpet is only fire boundary. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 22 May 2006
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 7 May 2002
Resolved
Renew air receiver to air compressor with a class II pressure vessel constructed to ASME U or UM standards in accordance with 46CFR54.01-5(c)(4).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 22 May 2006
Resolution: Air receiver removed.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 7 May 2002
Resolved
Provide a through hull isolation valve for the keel coolers or provide installation meeting 46CFR56.50-96(a)(2)(i). LEGACY COMPONENT DESC: Cooling water
Condition: Placed in Improper Service
Due 6 July 2006
Resolved 3 October 2006
Fire Fighting
Issued 10 March 1999
Resolved
Replace one B-II with a USCG or UL approved "marine type" fire extinguisher, and recharge or replace one other B-II extinguisher that is under charged. This must be corrected prior to getting under way and not later than 10APR99.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Deck/Cargo
Issued 10 March 1999
Resolved
Conduct test of cargo gear as described in 46CFR91.37-40, in the presence of a USCG Marine inspector.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 10 March 1999
Resolved
Replace the survival craft which was out for service, prior to getting underway.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 30 March 1998
Resolved
Provide evidence of crew enrolled in a drug testing program.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Fire Fighting
Issued 11 May 1997
Resolved
Have three fire buckets on board and ready for use as per new regs.
Condition: Unknown
Due 11 May 1997
Resolved 11 May 1997
Engineering
Issued 11 May 1997
Resolved
Install flame screens on both fuel tank vents.
Condition: Unknown
Due 11 May 1997
Resolved 11 May 1997
Lifesaving
Issued 11 May 1997
Resolved
Insulated the port main engine exhuast pipe to prevent injury to persons inthe engine room.
Condition: Unknown
Due 11 May 1997
Resolved 11 May 1997
Lifesaving
Issued 11 May 1997
Resolved
Install lights on the three exposure suits on board.
Condition: Unknown
Due 11 May 1997
Resolved 11 May 1997
Unknown
Issued 12 March 1991
Resolved
PLACE ONBOARD,HAND,FIRE / BILGE PUMP._x001C_ REF 46CFR 181.10-5
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Unknown
Issued 12 March 1991
Resolved
POST EMERGENCY CHECKOFF LIST IN PILOT HOUSE._x001C_ REF 46 CFR 185.25-1 / 185.25-5
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Navigation
Issued 12 March 1991
Resolved
PLACE ONBOARD,UPDATED EDITION OF NAUTICAL RULES OF THE ROAD,_x001C_ COMDTINST M16672.2B_x001C_ REF 46 CFR 185.20-35 h
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Construction/Loadline
Issued 12 March 1991
Resolved
STENCIL WATERTIGHT DOOR BETWEEN WELL DECK AND ENGINE ROOM IN ACCORDANCE_x001C_ WITH, 46 CFR 185.30-25
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Electrical
Issued 12 March 1991
Resolved
INSTALL BATTERY TRAYS FOR ALL ACID BATTERIES LOCATED IN THE ENGINE ROOM._x001C_ REF 46 CFR 183.05-20 d
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Electrical
Issued 12 March 1991
Resolved
REPLACE SEARCH LIGHT KNIFESWITCH WITH APPROVED ACCESSORY SWITCH_x001C_ REF 46 CFR 183.05-35 a
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Engineering
Issued 12 March 1991
Resolved
INSTALL GUARDS ON ALL ROTATING MACHINERY IN ENGINE ROOM,PORT AND STARBOARD ENGINE ALTERNATORS.BOW RAMP WINCH DRIVE UNIT. _x001C_ REF 46 CFR 177.35-15
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Unknown
Issued 12 March 1991
Resolved
CLEAN VESSELS BILGES OF ACCUMILATED OILS,DEBRIS,STORED CONTAINERS OR OTHER MATERIALS THAT WILL SUPPORT COMBUSTION OR CREATE A SAFETY HAZARD._x001C_ REF 46 CFR 185.30-20 a
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Unknown
Issued 12 March 1991
Resolved
INSTALL REACH RODS ON EMERGENCY FUEL SHUT OFF VALVES,TO OUTSIDE ENGINE ROOM,LABEL IN ACCORDANCE WITH. 46 CFR 185 30-20 a
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Electrical
Issued 12 March 1991
Resolved
INSTALL PRIMARY WIRE, (ALTERNATOR AND STARTER MOTOR) ON PORT AND STARBOARD MAIN ENGINES IN CONDUIT OR EQUIVELENT PROTECTIVE DEVICE TO PREVENT MECHANICAL DAMAGE._x001C_ REF 46 CFR 183.05-50 a 2
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Construction/Loadline
Issued 26 January 1988
Resolved
MAKE PERMANENT REAIRS TO BOTTOM LONGITUDINALS IN #1 AND 2 VOIDS.
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Construction/Loadline
Issued 26 January 1988
Resolved
MAKE PERMANENT REPAIRS TO FRAMEWORK IN #1 AND 2 VOIDS
Condition: Unknown
Due 26 January 1988
Resolved 26 January 1988
Lifesaving
Issued 11 February 1987
Resolved
ADD THREE (3) ORANGE SMOKE FLARES
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Construction/Loadline
Issued 11 February 1987
Resolved
FREE ALL DOGS ON WATERTIGHT DOORS AND CLEAN GASKETS
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987
Lifesaving
Issued 11 February 1987
Resolved
REPLACE TWO (2) LIFE PRESERVERS
Condition: Unknown
Due 11 February 1987
Resolved 11 February 1987