← All vessels
DL DAHLIA
DL DAHLIA is a 2013 freight ship. The Coast Guard has recorded 7 inspections since 2014, most recently in March 2024, along with 2 deficiencies and 3 operational controls.
Records from 2014 to 2024. Most recent: inspection, 12 March 2024.
- Built
- 2013
- Last inspected
- 12 March 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9659775 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FRN
1233664
Flag
PANAMA
—
Maury page id
psix-1233664
Inspections, by type
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it44603 - Convention (Subpart B), Gross Ton
27550 - Convention (Subpart B), Net Ton
96096 - Displacement, Ton
81667 - Dead Weight, Ton
27550 - Convention (Subpart B), Net Ton
96096 - Displacement, Ton
81667 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
12 March 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7869806
21 August 2020
Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7031057
12 August 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7031412
24 September 2016
Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6004321
29 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5010677
24 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5011645
20 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5022369
Deficiency record · 2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 August 2020
Resolved
"Stairways and lift truncks which penetrate more than a single deck shall be surronded by at least "A-0" class divisions and be protected by self-closing doors at all levels." PSCO observed 4 self closing doors leading out of Stairway held open with wood blocks and 2 self closing doors on the bridge held open with rope.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 August 2020
Resolved
"B" class divisions are those divisions formed by bulkheads, decks, ceilings or lining which comply with the following criteria: They are constructed as to be capable of preventing the passage of flame to the end of the first half hour of the standard fire test." PSCO observed a hole drilled in a "B" class fire boundary, between bathroom and VDR panle room on the bridge.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.