NORDIC LUEBECK is a 2013 freight ship. The Coast Guard has recorded 11 inspections since 2017, most recently in February 2026, along with 3 deficiencies and 2 operational controls.
Records from 2017 to 2026. Most recent: operational control imposed, 17 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it35351 - Dead Weight, Metric Ton 46153 - Displacement, Metric Ton 24341 - Convention (Subpart B), Gross Ton 12015 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
17 February 2026Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8311527
13 February 2026COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8310531
9 December 2025PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8278291
6 December 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8278472
3 July 2023Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7730727
22 September 2022Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7564267
13 May 2022PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7449804
23 May 2018ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6417219
15 November 2017Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6307657
15 November 2017Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6307682
13 November 2017Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6300732
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 December 2025Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed leak in fire main piping immediately down stream of emergency fire pump in emergency fire room.
74SOLAS(14) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2025
Resolution: PSCO cleared deficiency. Vessel replaced leaking pipe to the satisfaction of class and the Coast Guard.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 December 2025Resolved
The Oil Record Book Part 1 shall be completed on each occasion... Collection and disposal of oil residues (sludge). PSCO observed missing ORB entries. Corrections to the ORB must be made IAW MEPC.1/Circ.736/Rev.2 to account for the transfer of oil residues to the sludge tank.
MARPOL I/17.2.3
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 December 2025
Resolution: PSCO cleared deficiency on the spot after discussing with the Chief Engineer about the required entries for future entries.
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 15 November 2017Resolved
1410 - Propulsion main engine - Machinery, boilers and other pressure vessels shall be of design and construction adequate for service for which intended. Cylinder number three of the main engine crank case found to have metal particles. 74 SOLAS (14) II-1/26.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2017
Resolved 12 December 2017
Resolution: See Class and Tech report in documents.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.