Records from 2016 to 2026. Most recent: inspection, 19 February 2026.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portCLEARWATER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
19 February 2026
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8312740
29 May 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8127475
29 April 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8108844
11 June 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7917266
26 June 2023
COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7713415
17 May 2023
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7660333
5 October 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7570744
27 September 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7295440
19 April 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7178408
29 September 2020
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7060893
12 August 2019
In-Service Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6775576
16 May 2019
Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6679028
22 October 2018
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6565986
7 August 2018
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6505072
6 July 2018
COI Inspection · In-Service Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6469601
20 February 2018
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6358054
14 November 2017
Deadweight Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6306483
25 April 2017
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6122996
17 April 2017
In-Service Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6125962
16 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5878278
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2026
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q. MI observed an expired battery in the light apparatus. Replace battery.
Vessel restricted to daylight operations
46 CFR 180.70(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 April 2026
Resolution: Floating light battery replaced. See documents.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 April 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed missing contents of asprin. Replace.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 April 2026
Resolution: Aspirin replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. MI observed that the vessel's anchor light did not function. Vessel is restricted to daytime operations only until anchor light is functional.
46 CFR 183.420
Action required: 705 - Other - as specified
Due 29 April 2025
Resolved 10 May 2025
Resolution: Vessel rep sent photos of navigation lights working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2023
Resolved
Fuel tank vent pipes shall be installed to gradient upward to prevent fuel from being trapped in the line.
Starboard fuel tank vent was broken and not secured.
46 CFR 182.450(h)
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2023
Resolved 7 July 2023
Resolution: Received photo of newly installed fuel tank vent.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 26 June 2023
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously.
Rail mesh was ripping at top seams.
46 CFR 177.900(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2023
Resolved 7 July 2023
Resolution: Received photos of new mesh material on rails.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2023
Resolved
A portable hand bilge pump must be provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard.
Hand bilge pump was not long enough.
46 CFR 182.5209(b)(2) - 705c 7 days
Action required: 705 - Other - as specified
Due 3 July 2023
Resolved 30 June 2023
Resolution: Received photos of hand bilge pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. In the port side bilge, there were multiple connections made to two sea water pumps with twist on type connectors without any means to prevent loosening. One of these connections were hanging down into the bottom of the bilge.
46CFR183.340(i)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2019
Resolved 14 August 2019
Resolution: Wire connections replaced with end to end connections and secured out of the bilge.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 May 2019
Resolved
An internal structural examination conducted in compliance with §176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing, the hull plating and planking.
Inspector found de-lamination and separation of framing in starboard side aft of collision bulkhead.
Submit proposal and make repair available for marine inspector prior to credit drydock.
46 CFR 176.610(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 21 May 2019
Resolution: Repaired fiberglass and re-attached frame member.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 May 2019
Resolved
During the hull examination all accessible parts of the vessel’s under- water body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination.
Inspector found delamination to bottom of hull inboard Portside forward,
Submit proposal and make repair available for marine inspector prior to credit drydock.
46 CFR 176.610(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 21 May 2019
Resolution: Repaired crack to bottom of hull gel coat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 May 2019
Resolved
An internal structural examination conducted in compliance with §176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing,
Inspector found delamination of transverse strong back in port for-peak.
Submit proposal and make repair available for marine inspector prior to credit drydock.
46 CFR 176.610(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 21 May 2019
Resolution: Repaired strong back.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 May 2019
Resolved
During the examination all accessible parts of the vessel’s under- water body and all through hull fit- tings, including the hull plating and planking, and appendages shall be made available for examination.
Inspector found through hull plate cover gaskets in need of replacement.
Replace through hull plate cover gaskets.
46 CFR 176.610(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 21 May 2019
Resolution: Secured and sealed through hull covers.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 May 2019
Resolved
During the examination all accessible parts of the vessel’s under- water body and all through hull fit- tings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination.
Inspector found delamination on port-quarter deck exposing core material.
Submit proposal and make repair available for marine inspector prior to credit drydock.
46 CFR 176.610(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 21 May 2019
Resolution: Repaired port quarter hull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 May 2019
Resolved
During the examination all accessible parts of the vessel’s under- water body and all through hull fit- tings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination.
Inspector found port outboard engine skeg broken at the tip.
Repair or replace skeg and make repair available for marine inspector prior to credit drydock.
46 CFR 176.610(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 23 May 2019
Resolution: Replaced lower unit and skeg.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 May 2019
Resolved
During the examination all accessible parts of the vessel’s under- water body and all through hull fit- tings, including the hull plating and planking, appendages, propellers, shafts, bearings, and rudders shall be made available for examination.
Inspector found loose castle nuts on port and starboard propeller shaft.
Tighten port and starboard castle nuts to manufacturers specifications.
46 CFR 176.610(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 23 May 2019
Resolution: Tightened port and starboard castle nuts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 August 2018
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Found port side FRP hull reinforcement material wasted/worn beyond serviceable life. Vessel restricted from Beaching Operations as identified on COI until repairs are made. Provide repair proposal. 46 CFR 185.100
Action required: 705 - Other - as specified
Resolved 13 August 2018
Resolution: Verified satisfactory FRP repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 July 2018
Resolved
Vessel must undergo an inspection for certifiaction. You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection, as required in 46 CFR 176.105 of this part.
Vessel is operating with an expired COI. Submit application for renewal. 46 CFR 176.500(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2018
Resolution: Vessel completed renewal inspection on 10JUL2018.