Records from 2017 to 2024. Most recent: inspection, 23 January 2024.
Inspection history · 9
23 January 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7853238
4 December 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7828622
14 April 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7668796
4 March 2022
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7405691
12 June 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6974939
27 February 2020
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6912294
7 April 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6387085
22 March 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6371804
31 January 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6076293
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2023
Resolved
Electrical instalations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed electrical switch for washing machine in laundry room secured with zip ties and electrical tape due to broken bracket.
74SOLAS(20)II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2023
Resolved 23 January 2024
Resolution: A new electrical switch for washing machine in laundry room has been fitted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 December 2023
Resolved
Means of identifying the ship to which the lifeboat belongs and the number of the lifeboat shall be marked in such a way that they are visable from above. PSCO observed missing/worn call sign on top of lifeboat.
74SOLAS(20)III/34 LSA Code 4.4.9.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2023
Resolved 23 January 2024
Resolution: The call sign of ship to which the lifeboat belongs has been marked on top of lifeboat and is now visible from above.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 December 2023
Resolved
The name and port nof registry of the ship to which the lifeboat belongs shall be marked on each side of the lifeboats bow. PSCO observed missing name and port of registry marking on bow of freefall lifeboat.
74SOLAS(20)III/34 LSA Code 4.4.9.2
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2023
Resolved 23 January 2024
Resolution: The name and port of registry to which the lifeboat belongs has been marked on port and starboard side of the lifeboat. The lifeboat number has been marked on the lifeboat (fwd).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 February 2020
Resolved
15102 - Safety Management Systems - In meeting these requirements the company should ensure that appropriate corrective action is taken. NO.2 HFO tank sensor inoperable, vessel informed company in 2017 submitting part request which is still open. - 74SOLAS(14)IX/3.1 / ISM 10.2.3.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 February 2021
Resolved 12 June 2020
Resolution: received Survey attesting to repairs
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 22 March 2018
Resolved
0620-Inflatable Liferafts-Forward 6 man liferaft was not in it's stowed position. PSCO observed that the liferaft was damaged. C/O stated that damaged to forward liferaft occured during heavy weather encountered during transit. SOLAS 74 (2014) III/31.1.1.4
Action required: 705 - Other - as specified
Resolved 7 April 2018
Resolution: 07Apr18: Received class report from DNV GL Surveyor [name withheld], stating all outstanding deficiencies have been rectified. The class report stated: Forward liferaft replaced on board by new equipment.
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 22 March 2018
Resolved
0999-Other(safety in general)-Cargo hold not being properly ventilated. Cargo hold number 1 ventilation fan damaged. C/O stated that the damamge occured during heavy weather experienced during transit. SOLAS 74 (2014)I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2018
Resolution: 07Apr18: Received class report from DNV GL Surveyor [name withheld], stating all outstanding deficiencies have been rectified. The class report stated: Vessel removed damaged mushroom type vent head. Ventilation trunk was made watertight with blind
plate.