← All vessels
ROBIN
Offshore Supply Vessel · Offshore class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named ROBIN
ROBIN is a 2015 offshore supply vessel. The Coast Guard has recorded 24 inspections since 2014, most recently in December 2025, along with 43 deficiencies and 1 operational control.
Records from 2014 to 2025. Most recent: inspection, 12 December 2025.
- Built
- 2015
- Last inspected
- 12 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 43 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1258838
9732474 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDI3726
1234099
Flag
UNITED STATES
367691280
Maury page id
psix-1234099
Inspections, by type
…with no type recorded4
Years with a record
10 calendar years (2014–2025)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)250.0 ft × 57.0 ft × 20.0 ft
Registered tonnagegross 2,499 / net 1,117
ITC dimensions (L × B × D)250.0 ft × 57.0 ft × 20.0 ft
ITC tonnagegross 2,499 / net 1,117
BuilderBOLLINGER MARINE FABRICATORS INC · AMELIA, LA, UNITED STATES · built 2015
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3807 - Dead Weight, Metric Ton
2499 - Convention (Subpart B), Gross Ton
1117 - Convention (Subpart B), Net Ton
2499 - Convention (Subpart B), Gross Ton
1117 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI3726MMSI 367691280 · active · compulsorily equipped · granted 21 August 2025, expires 11 September 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 24
12 December 2025
COI Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8282784
10 December 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8271491
20 November 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8037459
19 December 2023
Annual Inspection · Annual Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7830498
18 December 2023
Internal Structural Exam · Cargo Tank Internal · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7840371
31 January 2023
Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7628948
28 August 2022
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7545641
28 August 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7557427
4 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7406143
8 December 2020
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7107801
16 June 2020
Administrative Inspection · Appeal
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6978380
20 March 2020
Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6929442
26 March 2019
Periodic Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6649181
3 January 2019
Cargo Tank Internal · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6607496
26 July 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6513291
15 December 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6324987
24 October 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6299108
25 September 2017
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6274679
15 September 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6267065
3 February 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6082187
8 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6040881
29 May 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5915834
17 April 2016
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5904164
5 March 2014
Hull Examination · Administrative Inspection · Internal Structural Exam · Construction Oversight · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5737364
Deficiency record · 43
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 January 2026
Resolved
Each OSV assigned a load line must meet Subchapter E (Load Lines) for closure of openings. The watertight escape hatches in the main machinery space and the rudder room were not watertight (daylight shining through closed hatch).
46 CFR 125.140(a)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 January 2026
Resolved
Required alarms in high ambient noise areas must be supplemented by visual means that are visible throughout these areas. Amber automation light in the engine room was inoperable.
46 CFR 62.25(d)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 January 2026
Resolved
Where pressure-indicating gages are used, the upper range of the gage must not be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. The relief valves on the bulk tanks were set to 90 psi, but the upper range of the gages were 200 psi.
46 CFR 54.15-5(f)
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 November 2024
Resolved
The emergency generator shall be started automatically upon failure of the electrical supply from the main source of electrical power and shall be automatically connected to the emergency switchboard. When the vessel went dark-ship for an operational test the emergency generator did not start.
74 SOLAS CONS 2014
2-1 Reg 42.3.1.2
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 November 2024
Resolved
Each OSV assigned a load line must meet Subchapter E (Load Lines) for closure of openings. The watertight escape within the main machinery space had daylight coming through after being dogged down, and was not watertight.
46 CFR 125.140(a)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 November 2024
Resolved
Structural fire protection including fire resisting divisions shall be kept in good order so as to ensure their required performance if a fire occurs. Multiple self-closing fire doors on the main stairwell were not self closing.
74 SOLAS CONS 2014
II-2 Reg 14.2.1.1.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 November 2024
Resolved
Cargo tanks shall be fitted with a visual and audible high-level alarm which complies with 15.19.1 to 15.19.5 and indicates when the liquid level in the cargo tank approaches the normal full condition. Vessel has CG-ENG mitigation letter to address IBC Code amendments dated 17FEB23 with an implementation due date by the vessel’s next dry docking following the date of the issuance of the letter. Vessel dry docked in DEC23 and was reissued a Certificate of Fitness by Class in APR24 and does not have the high-level alarm installed. Install prior to carriage of drilling brines containing calcium bromide.
74 SOLAS CONS 2014 VII Reg 10.1 // IBC Code 15.19
CG-ENG Policy Letter No. 03-12, CH-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 November 2024
Resolved
Where pressure-indicating gages are used in no case shall the upper range of the gauge be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. The port/Starboard start air receivers had 200 PSI gauges installed and relief valve settings at 198. The gauges are lower than the required range.
46 CFR 54.15-5(f)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 November 2024
Resolved
Each lens or diffuser of a lighting fixture must have a high strength guard or be made of high strength
material. In the main machinery space one light aft of the start air receivers had a busted lens and one above STBD breaker panels was melted.
46 CFR 129.410 (a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2024
Resolved
Each OSV must have, at the pilothouse, controls to start a fire pump and monitor the pressure in the fire main. During testing of the fire main, the pump pressure indicators were not reading correct values and showing only 02 PSI while the main was putting out adequate pressure.
46 CFR 130.430
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 November 2024
Resolved
Electrical equipment must be installed to minimize accidental personal contact with energized parts. Two breaker panels along the port bulkhead of the main machinery space were missing blanks, and there was a dead end wire on a distribution panel aft of the starboard air receiver.
46 CFR 129.200(c)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 November 2024
Resolved
Nothing in this part shall be construed as limiting the inspector from making such tests or inspections as he
deemed necessary to assure the safety and seaworthiness of the vessel. Vessels automation alarm light in the bow thruster space was inoperable, crew replaced the bulb and it was then made operable.
46 CFR 126.100
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 19 December 2023
Resolved
Design, construction, equipment, and operation of ships certified to carry NLS in bulk identified in Chapter 17 of the IBC Code, shall be in compliance with the IBC Code; vessel didn't have eyewash station or valves for sounding installed per letter 16714/2022-12-14T112434.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 19 December 2023
Resolved
A self-propelled vessel of at least 65 feet shall have a properly installed AIS Class A device; AIS was operational but couldn't be updated manually.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 December 2023
Resolved
Vessel must have an RAI at the steering control station; RAI (port rudder) at aft steering station in pilothouse reflected 05 degrees off while amidships.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 January 2023
Resolved
(1) Nonmetallic flexible hose must be in accordance with SAE J1942. The starboard MDE fuel hose was cracked at the bends. Replace hose with fuel standard hose meeting standard above.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 January 2023
Resolved
(a) Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. The fuel transfer meter and flange showed signs of leaking and presence of fuel. Repair and test.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2023
Resolved
(b) Each battery must be located as high above the bilge as practicable within the space the battery is located in and be secured to protect against shifting due to roll, pitch, and heave motions or vibration of the vessel, and free from exposure to splash or spray of water. The spare batteries in the E-gen space were not in containers and the posts were exposed. Secure and cover the posts.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 January 2023
Resolved
The fire integrity of the openings and penetrations shall be maintained. The fwd engine room bulkhead ventilation penetration fire stop was wasted. Replace sealant at penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 March 2022
Resolved
Each lifebuoy line must be fitted with line resistant to deterioration. Lifebuoy forward of the house had dry rotted line, must be replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 March 2022
Resolved
Each lifebuoy must be marked in block capitol letters with the name of the OSV and name of the vessel’s port. Ring life buoy on the aft deck port side must be stenciled in legible block letters, to be re-stenciled.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 7 March 2022
Resolved
Vessel must be provided with a recognized mobile satellite service ship station capable of transmitting and receiving distress and safety communications using direct-printing telegraphy. GMDSS printer not functioning, must be repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 March 2022
Resolved
All rescue boats must be properly constructed to be readily maneuverable. Rescue boats shall be constructed of materials accepted by the OCMI, as OCMI has final jurisdiction of construction. Fast rescue boat breaking through gel coat on upper port side. Must make repairs by an authorized party.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2022
Resolved
Gears, couplings, flywheels, and all machinery capable of injuring personnel shall be provided with adequate covers or guards. Aft rudder room p/s exhaust grates sustained substantial corroded from exhaust, must be replaced.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 8 December 2020
Resolved
Indication of the rudder angle must be provided both at the main steering station in pilothouse and in the steering gear compartment. Rudder angle indicator in the steering gear compartment was inaccurate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2020
Resolved
At least two (02) lifebuoys must be fitted with a self-activating smoke signal. Both bridge buoys had dryrotted bouyant line and the smoke signal was deattached.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 December 2020
Resolved
Each liferaft must be arranged for free-float launching. The arrangement must ensure that the liferaft when released and inflated, are not dragged under by the sinking OSV. Four (04) of the six (06) liferafts were incorrectly configured to not be float-free and remain attached to the vessel, if it were to sink.46CFR133.310(b)(7)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 December 2020
Resolved
Each vessel must have an amplifier-type announcing (PA) system that will supplement the general alarm. The PA system in the tank farm was inoperable.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 March 2020
Resolved
Before any vessel leaves protected waters, the master shall ensure that the vessel's exposed cargo hatches and other opening sin the hull are closed; made properly watertight by use of gaskets; and properly secured for sea. MI noted that escape hatch from dry bulk tank farm to aft deck was not watertight; forward section of hatch had exposed sunlight coming through opening between knife edge & gasket. Owner shall make escape hatch watertight prior to departure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 March 2020
Resolved
Any ship of 400 GT and above shall be fitted with oil filtering equipment that will ensure that any oil mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. MI discovered that pre-wash tank of installed oily water separator onboard was covered with black algae and the oil content meter was unable to function as prescribed by the manufacturer. Owner shall provide evidence of proper operation of the system to include filtering.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 March 2020
Resolved
MI noted extensive exhaust leak from port main diesel engine exhaust manifold. Owner shall repair leak to satisfaction of attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 March 2020
Resolved
In cargo ships of 2,000 GT and above, machinery spaces of category A above 500 cubic meters in volume shall be protected by an approved type of fixed water-based local application firefighting system. During testing of installed high pressure watermist system, the piping on the local pump station failed. Owner shall provide satisfactory operation of the installed fixed water-based local application firefighting system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 March 2020
Resolved
Each generator arranged for parallel operation must have reverse power or reverse-current trips. Owner shall provide proof of satisfactory reverse-power relays for two (02) installed generators.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
Deadend wires found in the engine room starboard side in the vicinity of the fuel transfer pump. Wires need to be removed or put in a junction box.
129.200
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2019
Resolved
Dead end wire found in the emergency generator room on the fuel tank just below generator. Wire needs to be removed or put in a junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2019
Resolved
Nonmetallic hoses from lube oil sump to turbo have 1 clamp on each connection point. Each connection point needs to be double calmmped on each generator and forward thruster prime mover.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 September 2017
Resolved
Vessel has unauthorized electrical equipment (Deck Lights) installed on deck in hazardous zones. ABS Electrical Hazardous Plan (Dwg E34 alt A0 02/08/17). Lights within the hazardous zones shall be Locked out/ Tagged out during flow-back operations and when independent tanks on the back deck are not certified gas free. Master must conduct JSA and ensure adequate lighting prior to night operations.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 3 February 2017
Resolved
Emberkation lights at port side embarkation station found not functioning.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 5 January 2016
Resolved
Vessel needs to place required marking for located at range disconnect
Communications › Radio Communications › EPIRB
Issued 5 January 2016
Resolved
ERIRB not properly registered with NOAA
Fire Fighting › Semiportable CO2 Fire Extinguishers › Securing Means
Issued 5 January 2016
Resolved
Semi-portable fire extinguishers needs to be properly secure to prevent movement during vessel operations
Fire Fighting › Ventilation Systems › Ducts
Issued 5 January 2016
Resolved
exhuast ducts leading into bow thuster room coming from engine space not properly sealed all the way around. Fire protection requirement due A-60
Stability › Weathertight Integrity › General
Issued 5 January 2016
Resolved
vsl needs to ensure all doors leading from bow thuster room up through accomandation up to bridge needs to properly close.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.