C-INSTALLER is a 2014 industrial vessel. The Coast Guard has recorded 17 inspections since 2016, most recently in April 2026, along with 10 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 8 April 2026.

Built
2014
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9670377
WDH2956
1235029
Flag
UNITED STATES
Maury page id
psix-1235029

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)278.4 ft × 66.0 ft × 26.0 ft
Registered tonnagegross 5,454 / net 1,737
ITC dimensions (L × B × D)278.4 ft × 66.0 ft × 26.0 ft
ITC tonnagegross 5,454 / net 1,737
BuilderNORTH AMERICAN SHIPBUILDING LLC · LAROSE, LA, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 January 2026 · expires 28 February 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9300 - Displacement, Gross Ton
5027 - Dead Weight, Gross Ton
5454 - Convention (Subpart B), Gross Ton
1737 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

8 April 2026 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8345139
22 February 2026 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8295715
16 February 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8311257
24 February 2025 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8060567
13 December 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8047192
28 June 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7986665
20 May 2024 TPO Audit · ISM Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7915907
28 February 2024 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7848665
23 August 2023 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7774529
14 June 2022 Annual Inspection · ACP Annual Oversight · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7457921
3 June 2021 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7221626
30 January 2020 MTSA/ISPS Verification · Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6899754
21 February 2019 ACP COI Oversight · MTSA/ISPS Verification · Re-Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6629537
6 April 2018 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6386346
27 February 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6362326
18 May 2017 Administrative Inspection · Periodic Inspection · ACP Periodic Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6150071
5 May 2016 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6084620

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 February 2026 Resolved
Unless otherwise expressly provided for in this subpart, the master, owner, operator, agent, or person in charge of vessels employing a Coast Guard-approved BWMS must meet the applicable ballast water discharge standard (BWDS), found in § 151.2030 of this subpart, at all times of discharge into the waters of the United States. USCG Sector New Orleans DMI received a report that the vessel has reported a malfunction in their ballast water treatment system due to a damaged UV Lamp and Sleeve. Vessel is restricted from discharging untreated ballast in waters of the United States until repairs are completed and a Class report attesting to satisfactory repair of the BWTS to Coast Guard Marine Inspectors.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2026
Resolution: Received satisfactory class report.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2025 Resolved
SOLAS 74 II-2/14.2 Three Semi-Portable fire extinguisher required as additional fire fighting equipment for the carriage of Methanol were found needing servicing and refilling.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 25 April 2025
Resolution: Received class report clearing requirement.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 June 2022 Resolved
Machinery spaces of cat A above 500m3 in volume shall in addition to fixed fire extinguishing system required in paragraph 5.1.1 be protected by an approved type of fixed water based or equivalent local application fire extinguishing system, based on the guidelines developed by the organization. MI observed water mist system activated in 3 zones - Stbd MDE, aft gen and fwd gen while testing remote activation test on the stbd MDE. Provide technician report to RO and CG stating system is operating as designed. 74solas2020 II-2/10.5.6.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 June 2022
Resolution: Received class report stating system is operating as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 14 June 2022 Resolved
Unless expressly provided otherwise, launching embarkation appliances complying with the requirements of section 6.1 of the code shall be provided for all survival craft. Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off power before the davit arms reach the stops in order to prevent over stressing the falls or davit, unless the motor is designed to prevent such over stressing. MI observed safety failed test of the limit switch.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: Davit limited switch was repaired and a sat test was witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 June 2022 Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self igniting lights complying with the requirements of paragraph 2.1.2 of the code. MI observed multiple ring buoys lifts that were not rigged as designed to be self ignited in case of deployment of ring buoy. 74solas 2020 III/7.1.3
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: all ring buoys lights were properly rigged
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 June 2021 Resolved
The training manual, which may be comprise of several volumes, shall contain instructions and information, in easily understood terms illustrated wherever possible, on the life-saving appliances provided. The SOLAS Training Manual on board the vessel is missing vital ship specific lifesaving appliances and training pertaining to the vessel. Vessel to provide a corrective action plan to update the vessels SOLAS Training Manual to reflect the actual lifesaving equipment on-board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2021
Resolution: The Training Manual was immediately updated with current Davit details, corrected with proper instructions. Actions to prevent recurrence has been taken in place by the Company.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 February 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Forwartd and aft generators were found to have one nonmetallic expansion joint located above each expansion tank showing severesigns of deterioration. Inspectors marked joints with an X. Replace both expansion joints prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 February 2020
Resolution: Expansion joint were replaced by vessel personnel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 February 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Three nonmetallic expansion joints were found to be in need of replacement due to cracks and dry rotting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 1 April 2020
Resolution: Vessel personnel replaced expansion joints with new ones. ABS cleared deficiency remotely due to COVID 19.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 21 February 2020 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Except as provided in regulation 14(2)m such covers shall be weathertight and fitted with gaskets and clamping devices. 02 Engineroom dampers and 02 cargo room dampers did not have the proper gasket that will provide with a proper seal.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2020
Resolved 1 April 2020
Resolution: Vessel personnel replaced seals with suitable material. ABS cleared deficiency remotely due to COVID 19.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard.Relief valves on one of the compressors were found to be with a higher PSI than required by the manufacturer. Requirement is 100 PSI on head and 150 on the line.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 February 2020
Resolution: Vessel personnel replaced relief valves with new ones with appropriate relief pressure.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.