Records from 2017 to 2026. Most recent: inspection, 17 April 2026.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 15.3 ft × 5.3 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderH & H MARINE INC · STEUBEN, ME, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFISHERS ISLAND, NY
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 21 November 2013
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
17 April 2026
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8351327
24 September 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8239132
14 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8097156
26 February 2024
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7854131
14 September 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7765049
3 April 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7647189
25 March 2022
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7403036
28 October 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7341928
12 May 2021
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7195361
12 March 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7145387
24 January 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6895652
17 October 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6812842
13 March 2019
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6641153
27 February 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6363142
27 November 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6313483
7 March 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6100475
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 March 2025
Resolved
Provide proof of servicing for the Fire Boy in the engine room. All portable FF was tagged, except the Fire Boy. Tested shut down and override sat.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 March 2025
Resolution: Proof of servicing provided
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 March 2025
Resolved
Steering space high water alarm is stuck in the on position (water sensor won't dry), repair/replace and prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 March 2025
Resolution: New High Water alarm installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 March 2025
Resolved
Repair/Renew stern light (flickering), not solid on. Restricted to daytime operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2025
Resolved 20 March 2025
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 14 March 2025
Resolved
Suspected hydraulic leak found Engine Room forward bulkhead (steering). Provide findings and how repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2025
Resolved 20 March 2025
Resolution: Completed, tightened fitting
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 February 2024
Resolved
Vessel req'd visual and audible signal at operating station for bilge alarms. Could not get E/R bilge alarm to go off. Repair/replace sensor or switch. This was corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 26 February 2024
Resolution: corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 March 2021
Resolved
Provide copy of IBA servicing certificate. Current inspection paperwork is expired. Route restriction to LBS w/in 1 mile of shore.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 May 2021
Resolution: Rec'd servicing certificate.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 March 2021
Resolved
Provide new hydrostatic release for the float free EPIRB. Attached hydro is expired. Vessel route restriction to w/in 3 miles of shore.
Action required: 705 - Other - as specified
Resolved 24 March 2021
Resolution: New hydro installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 March 2020
Resolved
At least one ring life buoy shall be fitted with a lifeline. No lifeline provided on the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 16 March 2020
Resolution: line provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2020
Resolved
Each child life jacket must be stowed separated from adult life jackets. Must provide barrier between adult and child PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 16 March 2020
Resolution: barrier provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 March 2020
Resolved
Provide portable hand bilge pump for vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 16 March 2020
Resolution: Pump provided
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2020
Resolved
Visual and audible alarms must be provided for all bilge high level alarms. Prove operation of steering and lazarette high water level alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2020
Resolved 16 March 2020
Resolution: Properly operating
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 March 2019
Resolved
Provide working bilge alarms for following compartments: Engine, Steering and Lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: all bilge alarms are working
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 March 2019
Resolved
Provide copy of new FCC Safety Certificate. (most current expired 25Feb2019).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: FCC Safety issued 3/15/2019 and expires 3/15/2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2019
Resolved
Provide a working approved battery for waterlight on Ring Life Buoy. Vessel is restricted to daylight operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2019
Resolved 20 March 2019
Resolution: new battery installed
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 13 March 2019
Resolved
Provide vessel with a current training logbook.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: logbook provided
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 March 2017
Resolved
Renew drip less shaft packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Installed new drip less shaft packing
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 7 March 2017
Resolved
Sewake tank leak
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Used 5200 caulk to secure leak
Engineering › Bilge Water Management System › Pump
Issued 7 March 2017
Resolved
Provide handle for portable bilge pump
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Purchased new portable bilge pump
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 March 2017
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Labeled buoy with vessel name/port
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 7 March 2017
Resolved
Leak (cooling) on 2 & 3 cylinder head discovered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Operator monitored area of leak. No further leaking or new leaks discovered. Provided pictures as evidence.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 March 2017
Resolved
Old bow thruster electrical components not removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 7 April 2017
Resolution: Removed all electrical equipment