MAURY USCG vessel records
← All vessels

NIMERTIS

NIMERTIS is a 2013 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in October 2024, along with 5 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 23 October 2024.

Built
2013
Last inspected
23 October 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9650999
1235351
Flag
LIBERIA
Maury page id
psix-1235351

Inspections, by type

Years with a record 6 calendar years (2016–2024)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it17025 - Convention (Subpart B), Gross Ton
10108 - Convention (Subpart B), Net Ton
34766 - Displacement, Ton
28396 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

23 October 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8023286
15 June 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7715919
12 October 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7575607
22 July 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6758296
15 July 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6750375
16 June 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6715420
20 July 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6214164
29 September 2016 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6009974

Deficiency record · 5

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 15 July 2019 Resolved
11102 FOOD RATIONS TOTALLY NOT LESS THAN 10,000 KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMMODATE; THESE RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING. THE AIRTIGHT PACKAGING FAILED ON 19 OF THE 25 FOOD RATIONS IN THE FREE-FALL LIFEBOAT. 74 SOLAS (14) III/31.1.1.1 LSA 4.4.8.12
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2019
Resolved 22 July 2019
Resolution: Class and CG verified that vessel purchased 25 new food packets and recieved them onboard stowed in lifeboat to replace damaged food.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 15 July 2019 Resolved
11124 MUSTER AND EMBARKATION STATIONS SHALL BE ADEQUATELY ILLUMINATED BY LIGHTING. LIGHTING AT FORWARD EMBARKATION AREA IS NOT WORKING 74 SOLAS (14)/11.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2019
Resolved 22 July 2019
Resolution: Class provided a report and CG verified onboard lights were in working order.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 July 2017 Resolved
PSCO FOUND 2KG EXTINGUISHER IN LIFE BOAT WAS DISCHARGED AND NOT MAINTAINED.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2017
Resolved 20 July 2017
Resolution: 2KG FIRE EXTINGUISHER WAS REPLACED PRIOR TO THE END OF EXAMINATION.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 20 July 2017 Resolved
PSCO NOTED 02 FIRE EXTINGUISHERS IN E/R HAD MISSING MONTHLY INSPECTIONS. VESSEL COMPANY IS TO PROVIDE CORRECTIVE ACTION PLAN.
Action required: 705 - Other - as specified
Due 20 August 2017
Resolved 10 August 2017
Resolution: RCVD DOCUMENTATION FROM COMPANY EXPLAINING ROOT CAUSE AND WHAT PREVENTATIVE MEASURES WILL BE TAKEN
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 20 July 2017 Resolved
PSCO NOTED A HOLD BACK DEVICE KEEPING THE SELF CLOSING SIGHT GLASS VALVE ON MAIN DIESEL ENGINE CYL OIL TANK IN THE OPEN POSITION.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 20 July 2017
Resolution: HOLD BACK DEVICE ON SELF CLOSING VALVE WAS REMOVED PRIOR TO THE END OF EXAMINATION.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.