PRINCE TLP

Built
2000
Last inspected
16 January 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF 8662
Flag
UNITED STATES
Maury page id
psix-12359

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

16 January 2026 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8297468
19 September 2025 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8238860
26 June 2024 Administrative Inspection · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7943732
2 February 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7931651
20 March 2023 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7654290
20 June 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482252
14 April 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7431304
10 June 2021 Administrative Inspection · COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7214320
18 September 2020 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7062122
6 September 2019 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6804940
29 October 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6570298
16 August 2018 Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6514824
26 July 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6222152
1 March 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6096984
27 February 2017 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6153636
26 May 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5887781

Deficiency record · 24

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 June 2024 Resolved
All marine engineering details, such as boilers, pressure vessels, main and auxiliary machinery, piping, valves, and fittings, shall be designed, constructed, and installed in accordance with the provisions of this subchapter. Observed the Main Gas Turbine A had severely corroded enclosure walls leaving large gap on lower section rendering the enclosure ineffective for its respective CO2 fire fighting suppression system. Main Gas Turbien A shall not be used until the enclosure structure is restored to its original strength as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2024
Resolution: Received docuentation and report of pictures showing new turbine enclosure walls installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2022 Resolved
Each applicant for approval of plans must submit three copies of each of the plans, specifications, and structural calculations concerning the construction, arrangement, required equipment, and safety features of the unit as described in 33 CFR 107.305. These include General Arrangement, Hull Structure, Stability, Fire Control, Marine Engineering, Electrical Engineering, Life Saving Equipment, Personnel Accommodations, Construction Portfolios, and the Operating Manual. The OCMI Office recognized on 4/14/22 that Portable Accommodation Modules (PAMs) were installed prior to CG Approval. Submit all approved plans for final review to the D8 OCMI Office and request inspection before occupying any of the three newly-installed PAMs.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 April 2022
Resolved 10 May 2022
Resolution: Satisfactorily examined installation of approved PAMs on the faciltiy.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 6 September 2019 Resolved
An employee may request an exemption from the restrictions of employment in 33 CFR 141.15..The operating company authorized Sonoco to bring out persons without citizenship requirements or exemption letter. Prince is not an authorized facility. 33 CFR 141.20(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2019
Resolved 13 November 2019
Resolution: Received CVC Approval Letter. Scanned into docs.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 6 September 2019 Resolved
Lifeboats which are also rescue boats are required to have a data plate which states they have been prototyped to 46 CFR 156. Provide required data plate. 46 CFR 160.156-17
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 2 October 2019
Resolution: Received email with photos of new data plates as well as a statement they were installed on each lifeboat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 September 2019 Resolved
The emergency equipment provided... shall be maintained in good condition at all times. Monthly maintenance of releasing gear is not being conducted IAW manufacturers recommendations. Implement and provide feedback. 33 CFR 146.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2019
Resolved 12 September 2019
Resolution: Received report from satisfactory third party testing.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 6 September 2019 Resolved
Each unit must carry at least one rescue boat approved under 46 CFR 160.156..and must have a rapid recovery winch. Prove by documentation or demonstrable evidence that winch meets rapid recovery standards. 46 CFR 108.560 and 108.570 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2019
Resolution: Received report from company attesting to satisfactory recovery test and document sshowing the same. Awaiting new placard from manufacturer.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 September 2019 Resolved
The emergency equipment provided, shall be maintained in good condition at all times. Lifeboat A and B have wastage at lowering/recovery sheaves and lifeboat B has a broken/modified cable pulley mount. Provide NDE and evaluation report from a third party to verify the integrity of welds and modifications/repairs. 33 CFR 146.15
Action required: 705 - Other - as specified
Due 13 September 2019
Resolved 12 September 2019
Resolution: Received report from third party, and repairs were made.
Electrical › Electric Generation Source (emergency) › Generator
Issued 26 July 2017 Resolved
During testing of the emergency generator, MI's observed loose fuel rail brackets. Remove all fuel rail brackets, inspect fuel rail, and repair to the satisfaction of the attending USCG Marine Inspector.
Due 2 August 2017
Resolved 2 August 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 July 2017 Resolved
During the inspection of the newly installed portable quarters, MI's observed the doors were listed as A60 Fire doors. However, no label was found and insufficient gasket material. Provide documentation attesting to fire class designation/rating and install to the satisfaction of the attending USCG marine inspector.
Due 26 August 2017
Resolved 2 August 2017
Lifesaving › Launching Appliances › Falls
Issued 27 February 2017 Resolved
Lifeboats A&B are past 4 yr fall renewal date. Lifeboats taken out of service and standby vessel required until boats are placed back in service. Operational control issued.
Due 10 March 2017
Resolved 10 March 2017
Resolution: Lifeboat falls renewed and load test completed. Proof provided via 3rd party report and verified by e-mail and site visit.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 27 February 2017 Resolved
Lifeboats A&B failed to start during inspection. Both boats already taken out of service due to fall renewal dates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 10 March 2017
Resolution: Lifeboats A&B starting system renewed via replacement of starters and alternators. Verified by e-mail with 3rd party report and by later inspection
Lifesaving › Lifeboat › Propulsion Engine
Issued 27 February 2017 Resolved
Lifeboats A-C have multiple repairs called out during last 3rd party servicing report with no resolutions >30days. Most notable were bad alternators on boats A&B and fuel leak on lifeboat A. It was noted that several smaller issues were noted, but no resolution taken. This resulted in an expanded SMS exam with BSEE to ensure the safety management system properly tracked maintenance and repairs.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 4 May 2017
Resolution: All items in 3rd party lifesaving report were cleared, including an new fuel tank installed in Lifeboat A. This def was extended due to lead time on fuel tank replacement by manufacturer. A report was provide by 3rd party service.
Lifesaving › Lifeboat › Fire Protection (general)
Issued 31 May 2016 Resolved
Lifeboat C is to be taken out of service until air bottle is changed out/recharged. Current bottle has no pressure therefore boat has no internal air supply and lacks adeqaute fire protection. 33 CFR 146.15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 1 June 2016
Resolution: new gauge + new bottle
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 31 May 2016 Resolved
Compressor control panels in hazardous location area is not sealed properly. Install control panel to Class I Div II requirements. PAJB5 Box has bare electrical wires. Install stuffing tubes to meet Class I Div II. [46 CFR 111.105]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 2 June 2016
Resolution: New parts installed
Fire Fighting › Fire Pumps › Power Source
Issued 31 May 2016 Resolved
Fire pumps A and B nitrogen bottles and guages are not functioning. Recharge bottles as needed (starting bottles) and replaces guages as needed. [46 CFR 108.415]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2016
Resolved 13 June 2016
Resolution: New bottles installed
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 May 2016 Resolved
Post fire control plan [46 CFR 109.563(a)]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 12 June 2016
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 31 May 2016 Resolved
Galley door does not latch. Install proper latch and remove hold back. [46 CFR 108.137]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 June 2016
Fire Fighting › Structural - B Class Divisions › Accommodation Spaces
Issued 31 May 2016 Resolved
B Class doors in accommodation spaces are modified (latches missing, handle plates/locks missing or modified) and are required to be restored to original. [46 CFR 108.143(a)]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 15 June 2016
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 31 May 2016 Resolved
Accommodation and TLP electrical distribution panels are not labeled properly. [46 CFR 111.40-11 (a + b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 1 June 2016
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 31 May 2016 Resolved
At least one door in the stairway is required to be self-closing/latching. Doors are modified and neither latch. Repair to original condition / replace. [46 CFR 108.143(a)]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 June 2016
Lifesaving › Lifeboat › Drain Valve
Issued 31 May 2016 Resolved
Remove diesel fuel from lifeboat A bilge, clear drain plug of obstructing debris.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 1 June 2016
Lifesaving › Launching Appliances › Davit
Issued 31 May 2016 Resolved
Grease sheaves IAW plan; provide maintenance plan for sheaves and falls. Sheaves squeeled excessveily during tests. BS stated that they never grease sheaves and solely rely on annaul maintenance by 3rd party. It had been 6 months + since last maintenance or inspection of davit, sheaves, falls, etc. [46 CFR 109.301(b)]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 1 June 2016
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 31 May 2016 Resolved
A-60 door in washroom TLQ does not latch; modified. Repair to original condition. [46 CFR 108.137]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 June 2016
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 31 May 2016 Resolved
Properly execute lock-out / tag-out procedures w/ distrubtion panels. [46 CFR 111.01-1(a)]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 1 June 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.