← All vessels
THE PROSPECTOR
THE PROSPECTOR is a 2013 tank ship. The Coast Guard has recorded 11 inspections since 2014, most recently in May 2026, along with 7 deficiencies and 1 operational control.
Records from 2014 to 2026. Most recent: inspection, 22 May 2026.
- Built
- 2013
- Last inspected
- 22 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9492323 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7AK6
1236503
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1236503
Inspections, by type
…with no type recorded2
Years with a record
7 calendar years (2014–2026)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it10830 - Convention (Subpart B), Gross Ton
3612 - Convention (Subpart B), Net Ton
21402 - Displacement, Ton
14968 - Dead Weight, Ton
3612 - Convention (Subpart B), Net Ton
21402 - Displacement, Ton
14968 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
22 May 2026
COC-CHEM & TVE Renew · Deficiency Check · PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8377842
21 November 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8036731
24 January 2020
In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6895468
24 January 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6900467
21 January 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6892936
26 September 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6818854
22 October 2016
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6025547
24 August 2016
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5981764
11 August 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5970193
26 October 2015
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam · COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5751217
6 October 2014
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4997749
Deficiency record · 7
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 22 May 2026
Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapour concentrations, together with a sufficient set of spares. Suitable means shall be provided for the calibration of such instruments. PSCO observed both portable gas instruments were not functioning as design.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 November 2024
Resolved
74 SOLAS (2009) II-2/9.4.2.2 Doors required to be self-closing shall not be fitted with hold-back hooks. However, hold back arrangements fitted with remote release devices of the fail-safe type may be utilized. Galley door is required by the fire control plan to be self-closing and was fitted with hold-back arrangements that required manual release from inside the space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 November 2024
Resolved
74 SOLAS (2009) II-2/9.4.2.1 The fire resistance of doors shall be equivalent of that of the division in which they are fitted, this being determined in accordance with the fire test procedures code... Doors fitted in boundary bulkheads of machinery spaces of Category A shall be reasonably gas tight and self-closing. Three (3) A-Class doors in machinery space were unable to close properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 November 2024
Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. For this purpose, the following functional requirements shall be met: escape routes shall be maintained in a safe condition. Two of the escape trunks from the machinery space (aft steering) had seized latches/dogs and were unable to be manipulated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2024
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, e.g. in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores, or similar spaces, unless the administration is satisfied that such equipment is appropriated certified for safe usage in the dusts, vapors, or gases likely to be encountered. Three (3) of the explosion-proof lights in the cargo pump room were broken and exposed to the surrounding atmosphere.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 21 November 2024
Resolved
Accumulator batteries shall be suitably housed, and compartments used primarily for their accomodation shall be properly constructed and efficiently ventilated. Battery room had two (2) loose batteries on the floor, and two (2) others were on the floor and secured with a rope.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 January 2020
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. While transiting to the berth at Centerpoint, the vessel suffered a reduction in maneuverability. PSCO received notification that the controllable pitch propeller controls in the engine control room malfunctioned.
SOLAS (2014) II-I/31.1 17ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.