← All vessels
LILA CUMBERLAND
LILA CUMBERLAND is a 2013 freight ship. The Coast Guard has recorded 3 inspections since 2022, most recently in November 2025, along with 3 deficiencies.
Records from 2022 to 2025. Most recent: inspection, 18 November 2025.
- Built
- 2013
- Last inspected
- 18 November 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9666649
5LLE7
1236512
Flag
LIBERIA
Maury page id
psix-1236512
Inspections, by type
Years with a record
2 calendar years (2022–2025)
The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it56531 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
33092 - Convention (Subpart B), Gross Ton
19229 - Convention (Subpart B), Net Ton
67681 - Displacement, Metric Ton
33092 - Convention (Subpart B), Gross Ton
19229 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
18 November 2025
PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8270910
31 May 2025
Deficiency Check · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8148701
3 January 2022
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7374822
Deficiency record · 3
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 November 2025
Resolved
steering gear control shall be provided where the main steering gear is arranged in accordance with paragraph 6, by two independent control systems, both operable from the navigation bridge.
PSCO observed inoperable non follow up control for pump one on navigation bridge. 74 SOLAS (14) II-1/29.7.2
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 9 June 2025
Resolved
The elecrical power available shall be sufficient to supply those services that are essential for safety in an emergency, due regard being paid to such services as may have to be operated simultaneously.
PSCO observed remote fuel supply valve closed for emergency generator.
16 (a) (c)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 June 2025
Resolved
Provisions shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery including boilers and pressure vessels.
PSCO observed oil accumulation for common rail on main diesel engine and throughout the engine room.
16 (a) (c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.