Records from 2016 to 2024. Most recent: inspection, 11 April 2024.
Inspection history · 13
11 April 2024
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7893800
11 April 2024
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7935010
2 April 2024
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7883642
31 August 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7781883
24 August 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7775388
28 September 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7568150
18 June 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7480767
24 September 2020
PSC A
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7061638
11 February 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6623803
16 December 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6590640
14 December 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6598948
31 July 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226252
25 October 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6029134
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 April 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel suffered an allision with another vessel after breaking free from its moorings in Tampa FL. PSCO observed damage on the port quarter of the vessel, yet was unable to verify condition of vessel below the waterline at the point of impact. Vessel is not permitted to depart berth 219 until deficiency is cleared.
74SOLAS (20) I/ 11
60 a.c.
Action required: 60 - Rectify deficiencies prior to movement
Due 11 April 2024
Resolved 13 April 2024
Resolution: Upon review of Class report, deficiency is resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 24 September 2020
Resolved
RESCUE BOATS SHALL BE STOWED: IN A STATE OF CONTINUOUS READINESS FOR LAUNCHING IN NOT MORE THAT 05 MINUTES. VESSEL'S DAVIT FOR RESCUE BOAT DOES NOT SWING HORIZONTALLY; THEREFORE VESSEL IS UNABLE TO LAUNCH THE RESCUE BOAT WITHIN THE 05 MINUTE REQUIREMENT. 74SOLAS(14)III/14.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2020
Resolved 25 September 2020
Resolution: Class carried out survey to verify rectification of deficiency issued regarding rescue boat davit. Documentation provided by class verifying operation of davit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 December 2018
Resolved
2199- Other(MARPOL operational Def.) After any survey of the ship has been completed, no change shall be made in structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. Vessel sewage plant arrangements provided a connection from the sewage collection tank to the gray water holding tank for retention of processed sewage. Crew is using a hose from the sewage shore tie connection to the aft peak tank without class society approval. In addition, the Sewage Certificate does not reflect the installed arrangements. 74 SOLAS(14) I/11(b)-40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 December 2018
Resolved 11 February 2019
Resolution: Vessel provided class approval of modifications to the vessel sewage plant arrangements
Fire Fighting › Means of Escape › Doorways
Issued 25 October 2016
Resolved
0960:Below teh lowest open deck the means of escape shall be a stairway and teh second escape may bea trunk or stairway. Door on main deck from stearing gear room exit was observed to be locked from teh outside; restricting the means of escape.
74 SOLAS (14) II-2/13.3.3.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2016
Resolved 29 October 2016
Resolution: Received class report attesting to repairs.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 25 October 2016
Resolved
The training manual shall be written in the working language of the ship. Observed the training manual in the crew mess room and throughout the ship written in English. The working language of the ship Chinese. 74 SOLAS (14) III/35.5
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2016
Resolved 29 October 2016
Resolution: Received class report of attesting to training manual in crews working language now present on board.
Lifesaving › Inflatable Liferafts › Markings
Issued 25 October 2016
Resolved
Provision shall be made for marking each liferaft with the name and port of registry of the ship to which it belongs. Observed starboard liferaft missing identification card.
74 SOLAS (14) III/31.1.3.1 LSA Chap. IV/4.2.7.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2016
Resolved 29 October 2016
Resolution: Received class report attesting to installation of identification card.