DEVBULK GULTEN

DEVBULK GULTEN is a 2013 freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in November 2025, along with 9 deficiencies and 3 operational controls.

Records from 2017 to 2025. Most recent: inspection, 7 November 2025.

Built
2013
Last inspected
7 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9659189
1237970
Flag
HONG KONG
Maury page id
psix-1237970

Documentation record

Tonnage as PSIX records it11814 - Convention (Subpart B), Net Ton
38302 - Dead Weight, Metric Ton
46558 - Displacement, Metric Ton
23749 - Regulatory (Subpart C or D), Gross Ton
11814 - Regulatory (Subpart C or D), Net Ton
23749 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

7 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8265632
14 February 2024 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7861061
7 February 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7385488
5 February 2022 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7391246
10 June 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6971528
9 October 2019 Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6822619
16 July 2019 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6745166
20 April 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6122951

Deficiency record · 9

14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 14 February 2024 Resolved
14799 - THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF ANY VESSEL EQUIPPED WITH BALLAST WATER TANKS THAT OPERATES IN THE WATERS OF THE UNITED STATES MUST FOLLOW THESE PRACTICES: REMOVE FOULING ORGANISMS FROM THE VESSEL'S HULL... AND DISPOSE OF ANY REMOVED SUBSTANCES IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGUALTIONS. PSCO OBSERVED EXCESSIVE HULL GROWTH ON THE MAJORITY OF THE SHIP'S HULL BELOW THE PLIMSOLL MARK. 33CFR151.2050F/40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 March 2024
Resolution: RECEIVED SURVEY REPORT ATTESTING TO RECTIFICATION OF DEFICIENCY.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 June 2020 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution, and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed fuel oil leaks and pooled oil on the three ship service generators and main engine. Additionally, numerous oil soaked rages were found presenting a significant fire hazard. 74 SOLAS 14 II-2/4.2.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2020
Resolved 10 June 2020
Resolution: Received ABS Class report, attached.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 10 June 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed port side stern mooring. Winch with hydraulic leak and numberous oil soaked rags underneath. 74 SOLAS 14 I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2020
Resolved 10 June 2020
Resolution: Received ABS Class report, attached.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 16 July 2019 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The vessel's crew failed to report nonconformities of critical items and functions IAW Chapter 9 of their SMS as indicated by deficiency #2. It is recommended that an external third party audit of the SMS be completed with regard to deficiency #2. 74 SOLAS(14)IX/3.1, ISM CODE 10.1, 30abc
Condition: Invalid
Action required: 30 - Ship detained
Due 16 July 2019
Resolved 24 July 2019
Resolution: Received, reviewed, and accepted ISM Audit from ABS stating Major Non-Conformity was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. Temporary repairs were found in the following spaces: Piping for the Fire/Ballast/Bilge pump has 2 temporary repairs; 1 repair has failed and is actively leaking. Piping for the Fire/General Service pump has 2 temporary repairs; 1 repair has failed and is actively leaking. Seawater cooling pump piping has a failed, leaking temporary patch and main engine cooling line has 1 temporary repair. Main engine heat exchanger seawater piping has two temporary repairs. The freshwater generator had 2 temporary repairs and one pinhole leak. Generator heat exchanger has two temporary repairs.74 SOLAS(14)II-1/26.1, 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 16 July 2019
Resolved 24 July 2019
Resolution: Received, reviewed, and accepted ABS class report stating vessel permanently repaired all piping issues. See attachment for specifics.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2019 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. PSCO identified multiple steam leaks from piping associated with the boiler system. Steam leak on the boiler, purifier flat and the #2 F. O. Tank steam piping on lowest deck of engine room. In addition, PSCO identified a temporary repair to the steam condenser for the cascade tank and weeping coming from the outboard side of the condenser indicating a material failure of the unit. 74 SOLAS(14) II-1/33.1, 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2019
Resolved 24 July 2019
Resolution: Received, reviewed, and accepted ABS class report stating steam system was permanently repaired. See attached report for specifics.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 16 July 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. BWMS showed multiple alarms , indicating it was not operating as designed. 74 SOLAS(14) 1-11(a) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2019
Resolved 24 July 2019
Resolution: Received, reviewed, and accepted class report issuing class recommendation for repair and proper operation of the BWTS until 23SEP19.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 16 July 2019 Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in tunnels which normally allow exhaust ventilation and closure of ventilator dampers. Main engine ventilation damper located above the scavenging airbox was missing.74 SOLAS(14) II-2/5.2.2, 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2019
Resolved 24 July 2019
Resolution: Received, reviewed, and accepted ABS class report stating new damper was installed and tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2019 Resolved
To discharge ballast water into waters of the United States, the master owner operator agent or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard as defined in 151.2030(a), use an AMS as described in 151.2025(a)(3) or ballast exclusively with water from a us public water system as described in 151.2025(a)(2). Vessels crew did not conduct ballast water treatment in accordance with their ballast water management plan. 33CFR 151.2035(a), 40c
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2019
Resolved 9 October 2019
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating the deficiency was rectified. Techcross technician verified that the ECS-RCM rectifier control module was replaced enabling BWMS to operate in emergency local control.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.