SEA LEOPARD

SEA LEOPARD is a 2011 tank ship. The Coast Guard has recorded 2 inspections since 2016, most recently in May 2019, along with 1 deficiency.

Records from 2016 to 2019. Most recent: inspection, 23 May 2019.

Built
2011
Last inspected
23 May 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9422615
1238858
Flag
MARSHALL ISLANDS
Maury page id
psix-1238858

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 2 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it161969 - Convention (Subpart B), Gross Ton
161969 - Regulatory (Subpart C or D), Gross Ton
112281 - Convention (Subpart B), Net Ton
112281 - Regulatory (Subpart C or D), Net Ton
314000 - Dead Weight, Metric Ton
343912 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

23 May 2019 COC-TVE Renew · Ballast Water Examination · ISPS II Exam · COE-Offshore
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6684068
2 March 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5825494

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 23 May 2019 Resolved
SOLAS 74 (2014) II-2/4.5.5.3.2 FSS Code 15.2.2.3.1 The inert gas system refferred to in paragraph 5.5.3.1 shall be designed, constructed and tested in accordance with the Fire Safety Systems Code. At least two blowers shall be fitted and be capable of delivering to the cargo tanks at least the volume of gas required by paragraphs 2.2.1.2 and 2.2.1.3. #3 blower has repair welds not approved by Classification Society. #2 blower was leaking inert as into the space and has a malfunctioning discharge valve.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 May 2019
Resolution: Lloyd's Register class report recived attesting to the repairs of the #2 and #3 blowers.