Records from 2016 to 2024. Most recent: inspection, 29 November 2024.
Inspection history · 45
29 November 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8041135
11 June 2024
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7932693
6 May 2024
Deficiency Check · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7904075
29 March 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7887138
27 March 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7884758
14 August 2023
Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7767834
1 February 2023
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7630215
6 July 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7498770
13 May 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7450136
20 March 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7415098
31 January 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7384634
7 December 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7364141
19 October 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7335640
28 August 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7298672
10 July 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7251397
26 May 2021
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7207124
24 May 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7205124
24 May 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7205341
20 May 2021
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7201786
12 May 2021
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7194953
11 February 2021
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7135633
9 February 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7138716
20 December 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7114890
29 October 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7086679
9 September 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7055077
9 September 2020
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7060180
30 July 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7020057
21 July 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7013159
21 July 2020
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7018345
10 March 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6921743
15 January 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6887048
3 December 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6865452
24 August 2019
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6790708
6 July 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6738091
11 May 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6685149
10 May 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6681572
20 February 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6628612
20 February 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6628613
27 August 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6524099
5 July 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6464451
26 June 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6456441
25 June 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6453800
25 June 2018
COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6455895
31 January 2017
NPV Safety Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6079843
31 March 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5842697
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 May 2024
Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and self closing doors. Class "A" self closing door to bridge did not self close and was held open with a tie back.
74SOLAS(04)II-2/9.2.3.4.1
Action: 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 May 2024
Resolved 6 May 2024
Resolution: Crew adjusted door self closing mechanism and removed tie back.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 March 2024
Resolved
Power ventilation...shall be capable of being stopped from an easily accessible position outside the space being served. Louvers on cargo deck 8 were not able to close fully.
74 SOLAS (04) II-2/5.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2024
Resolved 27 March 2024
Resolution: Vessel was able to fix louvers with the PSCO observing them in operation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 March 2024
Resolved
The following fire protection systems shall be kept in good order..including fire resisiting divisions, and protection of openings and penetrations in these divisions. 02 fire doors on decks 9 and 11 did not have self-closing capabilities.
74 SOLAS (04) II-2/14.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2024
Resolved 27 March 2024
Resolution: Crew was able to make repairs on the spot to the satisfaction of the PSCO.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 March 2024
Resolved
The marking required by paragraphs 4.2.6.3.5 on liferafts equipped in accordance with paragraph 4.1.5.1 shall be "SOLAS A PACK" in block capitals of the Roman Alphabet. Port liferaft was labeled as "NON OP for production only" for the Emergency pack type.
74 SOLAS (20) III/34
LSA Code 4.1.5.2
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 July 2018
Resolved
Access doors shall open outward, and bulkheads and decks, including doors and other means of closing any opening therein, which form the boundaries between such rooms and adjacent enclosed spaces shall be gastight. Port State Control Officers observed main access door to low-pressure CO2 room opens inward.
(Cite) 74 SOLAS (14) II-2/10.4.3 (Action Taken) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 August 2018
Resolution: Vessel submitted class report attesting to rectification.