Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 2 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton 735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 20
13 November 2025COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8268688
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date, except as specified in paragraph (b) of this section. Vessel missed 90 day window to schedule an annual inspection. Vessel will need to complete a COI renewal.
46 CFR 31.10-17(a)
Action required: 10 - Deficiency Rectified
Resolved 14 November 2025
Resolution: Conducted COI inspection for vessel. Renewing current COI.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 3 April 2023Resolved
Safety relief valves shall be tested by bench testing or other suitable means. This test shall be conducted at the time of the inspection for certification.
Vessel's High Velocity P.V. Valve was last bench tested at the previous COI Apr 2019.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 4 April 2023
Resolution: Rep provided documentation of test
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 April 2023Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open.
The stamped inspection date on the relief valve was 2019.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 4 April 2023
Resolution: Rep. provided test certificate.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 April 2023Resolved
Cargo pump pressure gage shall be tested at least once a year for accuracy.
No documentation or proof of testing was provided at the time of inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 4 April 2023
Resolution: Rep provided certificate of testing
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 April 2023Resolved
The cargo discharge piping of all tank vessels shall be tested at least once each year for tightness, at the maximum working pressure.
No documentation or proof of testing was provided at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2023
Resolved 4 April 2023
Resolution: Rep provide testing certificate.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 May 2019Resolved
High Level Alarm sensor was non operational
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 May 2019
Resolved 2 May 2019
Resolution: Sensor was replaced