Records from 1991 to 2014. Most recent: inspection, 5 May 2014.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
5 May 2014
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4851004
19 August 2011
Hull Examination · Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4120754
18 August 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3332146
24 March 2008
COI Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3170302
19 April 2005
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2337428
8 April 2004
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2039847
7 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1741224
25 January 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1482550
16 January 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382113
14 January 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453707
12 January 1999
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400905
6 February 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1112021
16 January 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372094
23 July 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1115533
14 February 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1105991
17 January 1997
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419702
21 December 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 875778
17 March 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 870301
4 January 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1161373
15 September 1993
Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459817
4 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 943206
17 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248806
9 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243767
2 April 1991
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928926
Construction/Loadline › Hull › Hull Plating
Issued 5 May 2014
No resolution recorded
Vessel found in a substantially substandard condition. Vessel has at least 25 very large holes in both the internal and outer portions of the deck. Hull condition is such that the vessel must be inspected by a certified marine survey and repair proposals submited for approval to the CG. Vessel must undergo a new Hull, ISE, and COI inspection prior to returning to service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 August 2011
Resolved
Install emergency lighting by escape in enginroom.
Action required: 705 - Other - as specified
Resolved 29 August 2011
Resolution: Vessel installed emer lighting near escape.
Communications › Alarms/Indicators › General Alarm
Issued 19 August 2011
Resolved
Demenstrate proper operation of tilt alarm.
Action required: 705 - Other - as specified
Resolved 30 August 2011
Resolution: Witnessed sat operation of tilt alarm.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 August 2011
Resolved
Demenstrate proper operation of nav lights.
Action required: 705 - Other - as specified
Resolved 30 August 2011
Resolution: Witnessed sat operation of nav lights.
Fire Fighting › Fire Pumps › Pressure
Issued 19 August 2011
Resolved
Demonstrate proper operation of the fire pump.
Action required: 705 - Other - as specified
Resolved 29 August 2011
Resolution: Conducted operational test of fire pump. all sat
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 August 2011
Resolved
Repair crack on stbd leg HYD supply line.
Action required: 705 - Other - as specified
Resolved 29 August 2011
Resolution: Pipe was repaired and pressure tested. All sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 August 2011
Resolved
Remove dead-end wires in enginroom.
Action required: 705 - Other - as specified
Resolved 30 August 2011
Resolution: Dead end wires removed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 March 2008
Resolved
Show proper operation of emergency fuel shut off.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 24 March 2008
Resolved
Show proper operation of installed tachometers for Main Engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Lifesaving › Lifefloat › Float Free
Issued 24 March 2008
Resolved
Replace Float free weak link
Due 15 May 2008
Resolved 16 April 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 March 2008
Resolved
Mark lifejacket stowage locker with proper number of life jackets
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Lifesaving › Rescue Boat Equipment › Painter
Issued 24 March 2008
Resolved
Replace rescue skiff lifting sling.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Documentation › Certificates/Documents › FCC SSL
Issued 24 March 2008
Resolved
Obtain FCC Radio Station license and operator's permit
Due 15 May 2008
Resolved 23 April 2008
Operations/Management › Drills/Instruction › Fire
Issued 24 March 2008
Resolved
Post Emergency Instructions
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 March 2008
Resolved
Install blanks on switchboard to prevent accidental contact with electrical source. Panel door- install latch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 24 March 2008
Resolved
Install latches on refrigerator, freezer, an oven
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Engineering › Lubricating Oil Service System › Piping
Issued 24 March 2008
Resolved
Replace deteriorated flexible piping on Port Main lube oil pressure supply line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Engineering › Reduction Gearing/Clutches › Shaft
Issued 24 March 2008
Resolved
Install shaft speed rpm guage or create a chart for rpm/shaft ratio @ 50 rpm increments
Due 15 May 2008
Resolved 16 April 2008
Resolution: Createdc hart
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 March 2008
Resolved
Have new crew practice drills and perform upon followup
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Construction/Loadline › Structures › Door
Issued 24 March 2008
Resolved
Make all doors and windows on main deck weather tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 25 January 2002
Resolved
Crop & renew 18" of wasted bottom angle IWO stbd bow.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2002
Resolution: Bottom angle replaced.
Construction/Loadline
Issued 16 January 1998
Resolved
PROVE HULL AREA AND REMOVE RED HAND FROM STERN BILGE AREA AND SUBMIT REPAIRPROPOSAL.
Condition: Unknown
Due 15 February 1998
Resolved 12 February 1998
Lifesaving
Issued 16 January 1998
Resolved
PROVIDE PROPER HYDROSTATIC RELEASE FOR 406 EPIRB INSTALLED ON BOARD.
Condition: Unknown
Due 15 February 1998
Resolved 12 February 1998
Engineering
Issued 16 January 1998
Resolved
PROVE PROPER OPERATION OF FUEL SHUT-DOWN.
Condition: Unknown
Due 15 February 1998
Resolved 12 February 1998
Electrical
Issued 16 January 1998
Resolved
PERMANENTLY WIRE AND PROVIDE WATERTIGHT PLUG AND MAKE PROPER PENETRATION FOR SHORE TIE ELECTRICAL CABLE.
Condition: Unknown
Due 15 February 1998
Resolved 12 February 1998
Navigation
Issued 17 January 1997
Resolved
PROVIDE ON BOARD 46 CFR SUBCHAPTER I, COAST PILOT, AND TIDE TABLES.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Documentation
Issued 17 January 1997
Resolved
PROVE REGISTRATION OF CAT 1 EPIRB, WITH NOAA.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Documentation
Issued 2 April 1991
Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Navigation
Issued 2 April 1991
Resolved
CALIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld], LA.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Documentation
Issued 2 April 1991
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER,WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Documentation
Issued 2 April 1991
Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Documentation
Issued 2 April 1991
Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C., VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL ISRECEIVED.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Electrical
Issued 2 April 1991
Resolved
PROVE PROPER OPERATION OF GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991