MAURY USCG vessel records Sign in
← All vessels

IB1064

IB1064 is a 2013 tank barge. The Coast Guard has recorded 13 inspections since 2013, most recently in August 2023, along with 1 deficiency.

Records from 2013 to 2023. Most recent: inspection, 1 August 2023.

Built
2013
Last inspected
1 August 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1240011
Flag
UNITED STATES
—
Maury page id
psix-1240011

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (2013–2023)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.0 ft
Registered tonnagegross 705 / net 705
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · CARUTHERSVILLE, MO, UNITED STATES · built 2013
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it705 - Simplified, Gross Ton
705 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

1 August 2023 Cargo Tank Internal · MTSA Verification · Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7742409
12 September 2019 Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6810366
13 July 2019 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6750347
27 July 2018 Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6488748
14 September 2017 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6282201
18 April 2017 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6127524
14 November 2016 Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6040850
10 October 2016 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6053935
24 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5982188
14 September 2015 Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5718379
29 October 2014 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5017952
29 October 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5022717
8 August 2013 Internal Structural Exam · Administrative Inspection · Initial Certification · Drydock Exam · MTSA Verification · Cargo Tank Internal · Initial Construction-Excluding Oversight
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4679049

Deficiency record · 1

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 August 2023 Resolved
The vent header shall be fitted with a flame arrester or pressure vacuum relief valve. Flame screen on mast riser had significant debris build up. Repair or replace to operate as designed. Rectify prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2023
Resolution: Renewed flame screen.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.