TOBIAS

TOBIAS is a 2013 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in May 2026, along with 78 deficiencies, 3 operational controls and 1 casualty investigation in 2019.

Records from 2016 to 2026. Most recent: inspection, 26 May 2026.

Built
2013
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN9612
1241020
Flag
UNITED STATES
Maury page id
psix-1241020

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TORTUGA Passenger (Inspected) · MISLE 1436428 · 4 January 2019 · activity 6647190

Inspection history · 22

26 May 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8377071
17 September 2025 Hull Examination · Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8235222
13 July 2025 Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8185039
5 July 2025 Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8187286
31 May 2025 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8148791
31 May 2025 Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8151731
25 July 2024 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7966921
28 July 2023 Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7754682
7 July 2023 COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7725628
12 September 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7557160
20 July 2021 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7261797
26 April 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7183386
15 July 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7006808
6 August 2019 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6774743
17 July 2019 Administrative Inspection · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6741510
5 January 2019 Deficiency Check · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6605853
4 January 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6647190
10 July 2018 COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6473889
7 October 2017 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288919
26 July 2017 Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6219171
11 July 2017 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6205056
10 August 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5968173

Deficiency record · 78

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2026 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge;(2) An audible alarm that sounds upon discharge; and(3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. The indicating light, audible alarm, and reset device were inoperable. Repair the systems and demonstrate their function. 46 CFR 181.420(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2026
Resolution: Satisfactory testing.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 May 2026 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The visual and audible high water alarms were inoperable in all three compartments. The visual bilge alarm was inoperable in the forward compartment. Demonstrate the function of the alarms. 46 CFR 182.530 (a)(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 June 2026
Resolution: High water alarms tested and found in normal operations.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 May 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. The hydrostatic release for the EPIRB was expired and the batteries inside the EPIRB were expired. Replace the hydrostatic release and the batteries. 46 CFR 176.808 (a)(5)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2026
Resolution: Provided photographic evidence of new batteries and hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 May 2026 Resolved
The float free link for the life float must be: secured to the painter at one end, and to the vessel on the other end. The link was not secured. Secure the link to the vessel. 46 CFR 180.137 (b)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2026
Resolution: Provided photographic evidence of link secured to vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 May 2026 Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly. Testing was not documented in the vessel log. Demonstrate evidence of testing. 46 CFR 185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 29 May 2026
Resolution: Provided vessel log entry of EPIRB testing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2026 Resolved
The Master shall conduct frequent abandon ship, and man overboard drills to ensure crew familiarity with emergency duties every month but at least once every three month period. Drills must be formally recorded in the vessel’s official logbook, including the date of the drill and a summary of the instructions given. Drills were not documented in the vessel log. Demonstrate evidence of drills. 46 CFR 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 29 May 2026
Resolution: Provided vessel log entry of drills.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 May 2026 Resolved
The inspection and maintenance of survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. Maintenance was not documented in the vessel log. Demonstrate evidence of maintenance. 46 CFR 185.702(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 29 May 2026
Resolution: Provided vessel log entry of maintenance.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 May 2026 Resolved
Marine employers must ensure personnel directly involved in a Serious Marine Incident (SMI) undergo alcohol testing (breath, blood, or saliva) within two (2) hours. On board saliva swabs were expired, the breathalyzer was uncalibrated, and the personnel were not trained to administer tests. 46 CFR 4.06-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 29 May 2026
Resolution: Provided photographic evidence of testing strips.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 26 May 2026 Resolved
The float free link for the life float must be: Certified to meet § 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. The link was missing the identification tag. Replace the tag. 46 CFR 180.137
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 28 May 2026
Resolution: Provided photograph of the installed tag.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2026 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The name was worn. Rewrite the name. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 29 May 2026
Resolution: Provided photographic evidence of buoy with legible name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2026 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The life jacket stowage location was not marked. Add the marking. 46 CFR 180.78
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 28 May 2026
Resolution: Provided photographic evidence of child lifejacket compartment marking.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 May 2026 Resolved
Provision must be made for closing all supply duct openings for a space protected by a fixed gas extinguishing systmen. Under seat air dampeners for the machinery space fire extinguishing system are blocked by PFDs, preventing rapid emergency closure. Clear PFDs from the dampener access area and stencil the closure locations for immediate visibility.46 CFR 182.465 (h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 29 May 2026
Resolution: Provided photographic evidence of clear damper access and marking.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 26 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Three dead end wires were located under the operating station. Properly remove or cover the wires. 46 CFR 183.200 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 10 July 2026
Resolution: Wires removed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 May 2026 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The life float had multiple fractures. Repair the fractures. 46 CFR 180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 10 July 2026
Resolution: Fractures sufficiently repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Three adult life jackets were inoperable. Replace the life jackets. 46 CFR 180.71
Action required: 10 - Deficiency Rectified
Due 26 May 2026
Resolved 26 May 2026
Resolution: Replaced 03 adult life jackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2025 Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. The vessel was found employing 02 crewmembers onboard that are not part of the chemical testing program established by the marine employer. 46 CFR 16.230 (a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacture's instruction. There are two openings one port and one stbd in the forward engine room bulkhead. Make the two openings vapor tight so the extinguish medium will not escape the engine room to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2024
Resolved 1 August 2024
Resolution: Received photos of the fire resistant foam filled in the through hole penetrations.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2024 Resolved
The Rules concerning lights shall be complied with from sunset to sunrise. Stbd navigation light not working. Restricted to daytime operations until replaced to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2024
Resolved 1 August 2024
Resolution: Received photos of the navigation light operational.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 July 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release unit for EPIRB is expired. Vessel is restricted to operate within 3nm until replaced to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2024
Resolved 1 August 2024
Resolution: Installed new hydrostatic release in accordance with 46 CFR 185.740(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 July 2024 Resolved
A hatch exposed to the weather must be watertight. Port engine room hatch gasket was torn where it seats on the knife edge. Replace to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2024
Resolved 8 August 2024
Resolution: Received photos of the new gasket.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 31 July 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Multiple dead-end wires were found underneath the main operating station. Rectify to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2024
Resolved 8 August 2024
Resolution: Received photos of the dead end wires caped.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 September 2022 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: A space containing propulsion machinery. Vessel's pre-engineered fixed gas fire extinguishing system bottle was found to be leaking contents. Bottle must be replaced and certified operable by technician. Testing of system to include engine shutdown and over ride must be witnessed by attending marine inspectors. 46CFR181.400(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2022
Resolution: New system installed and tested.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 September 2022 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Inspectors identified fracture in center void space on a structural longitudinal member on the port side of the vessel beneath the waterline. Crew must clean and expose area to identify extent of damage and needed repairs. 46CFR176.840
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2022
Resolution: Repaird FRP and reinforced.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 September 2022 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. While inspection forepeak void, minor de-lamination was noticed on the port side where anchor line is stored. Repair de-laminated area to satisfaction of attending inspector. 46CFR176.802
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2022
Resolution: De lamination sanded down and repaired.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 September 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port side damper does not latch closed and is missing pieces of gasketing which would create a tight closure when shut. Replace gasketing and adjust latch assembly so damper can be securely closed. 46CFR182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2022
Resolution: Damped locking mechanism was replaced as was gasketing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel crew created 02 inspection/cleaning ports on both the port and stb fuel tanks. No special consideration letter was issued to vessel and pressure testing of each tank never took place. Crew must submit documentation regarding alteration, any testing done, and prepare for pressure testing in the presence of attending marine inspector. 46CFR176.600
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Vessel will be submitting special consideration for access ports.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 12 September 2022 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The equipment required for lifefloats and buoyant apparatus must meet the following specifications: The painter must be stowed in such a way that it runs out freely when the life float or buoyant apparatus floats away from a sinking vessel. Lifefloat painter line is stowed in metal apparatus which has a fractured metal guard. This guard, since broken, now leaves an exposed end which no longer guides the line but will instead catch when unspooling. Repair/replace metal guard to prevent catching of painter line during emergency. 46CFR180.175(f)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: New cage was isntalled.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 September 2022 Resolved
Equipment specifications for life floats and buoyant apparatus. The equipment required for lifefloats and buoyant apparatus must meet the following specifications: (2) Paddle. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Paddles were not lashed to lifefloats. 46CFR180.175(f)(2)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Paddles were lashed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 September 2022 Resolved
In addition to meeting § 180.130, each life float and buoyant apparatus must be stowed as required under this section, (f) Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Vessel had life floats stacked with no spacers. 46 CFR 180.137(f)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Spacers were inserted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2022 Resolved
Inspection and testing. All portable fire extinguishers, must be inspected or tested at least once every 12 months. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Monthly checks were not logged or carried out. 46 CFR 142.240(a)(1)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Crew was instructed and will log and condcut monthly inspections.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 September 2022 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel did not have COI or stability letter posted. 46 CFR 176.306
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: posted.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 12 September 2022 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include -(1) Closing each valve leading to an overboard discharge and removing the handle;(2) Padlocking each valve leading to an overboard discharge in the closed position; or(3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Vessel did not have a means of securing MSD. 33 CFR 159.7(c)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Space to overboard valve will be isolated in port and overbaord shut.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2022 Resolved
All cable and wire must be protected from the weather. Dead end cable were found on the stbd aft section of the engine space. Remove dead end wires. 46 CFR 183.340(b)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Removed cables.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 September 2022 Resolved
The manufacturer's instructions for onboard maintenance of survival craft, rescue boats, and launching appliances, manufactured on or after March 11, 1996, must be readily available for a vessel of not more than 19.8 meters (65 feet) in length. The vessel has a two inch by three inch area of wastage on the top most lifefloat. Repair as per manufacturers instructions. 46CFR185.702
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Life float was repaired and wrapped for protection. Vessel was informed that this manner is not consitent with manufacturer repair guidelines, however does protect and keep lifefloat redily availble for use.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 September 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. vessel lacked instructions for heavy weather at the operating station. 46CFR185.510
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: added.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2022 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel must conduct fire and man overboard drills. 46CFR176.840
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2022
Resolved 4 October 2022
Resolution: Talked through process and procedures for man overbaord and fire drill.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 May 2021 Resolved
The machinery space must be equipped with a fixed fire extinguishing system. Vessel self-reported accidental discharge of fireboy while conducting maintenance. Vessel issued code 17 until fireboy system is serviced and certified to be operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2021
Resolution: Vessel representative sent paperwork demonstrating the fireboy was serviced and certified to be working via operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. The protective outer jacket of the wire used for the manual discharge of the fire boy was wasted and peeling off. The wasted part of the wire is located in the forward void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 11 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 April 2021 Resolved
An adult life jacket must be provided for each person carried on board. The vessel COI allows for 52 passengers; the vessel had 51 life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2021 Resolved
The number of life jackets must be marked and clearly legible where they are stowed. Life jackets stowed overhead did not display the correct number of life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2021 Resolved
The vessel must carry one floating water light with its ring life buoy. The water light battery was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2021 Resolved
Each life float must be fitted with a light. Batteries for the water lights were inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 April 2021 Resolved
When stowed in tiers, life floats must be separated by spacers. Life floats were missing spacers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2021 Resolved
Each EPIRB must be tested monthly, and logged. EPIRB testing did not appear in vessel log.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 April 2021 Resolved
Abandon ship, man overboard, and fire drills shall be conducted monthly, and logged. Drills did not appear in vessel log.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 April 2021 Resolved
A hatch exposed to the weather must be watertight. The rubber gasket on the forward hatch was not properly attached.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 21 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 July 2020 Resolved
A vessel on a limited coastwise route must carry six red distress signals and six hand orange smoke distress signals. Vessel was missing two distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 8 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 July 2020 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. Visual high level alarm was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 8 September 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2020 Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon fire buckets. Vessel was missing one fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 14 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2020 Resolved
Connection must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Both batteries contain wing nuts on the battery posts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 8 September 2020
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 23 July 2020 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the oprating station, emergency instructions containing the actions to be taken in the of fire, heavy weather, or man overboard condiitions. Vessel owner couldn't provided emergency instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 14 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, and the vessel from electrical hazards. Vessel had dead end cables at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 14 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 July 2020 Resolved
Placards containing instructions for the donning and use of life jackets aboard the vessel must be posted, in place that are regularly accessible and visible to the crew and passengers. Vessel did not have a life jacket placard posted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 8 September 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 July 2020 Resolved
Abandon ship and man overboard drills and training shall be logged or documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training, and general description of the drill scenario and taining topics. Details for drills and logs provided were insufficient.
Action required: 10 - Deficiency Rectified
Due 20 August 2020
Resolved 23 July 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 July 2020 Resolved
Transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit of the class required below. Current captain of the vessel could not provide a radio operator permit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 8 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 January 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Both port and starboard main engines are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2019
Resolution: Shafts were re-aligned and sea-trails were conducted with no issues noted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2018 Resolved
Two (02) of the three (03) portable fire extinguishers need to be serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 16 July 2018
Resolution: Completed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 July 2018 Resolved
Both life floats were not affixed with a float-free link.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2018
Resolved 16 July 2018
Resolution: Link was installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 October 2017 Resolved
Demonstrate proper functioning of bilge pump suction system
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2017
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 7 October 2017 Resolved
Secure Railing COnnections to canopy framing with appropriate hardware
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 October 2017 Resolved
Pump-out fwd void ahead of collison bulkhead and prepare for internal inspectoin
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 7 October 2017 Resolved
Provide working high water bilge alarm indication
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 25 January 2018
Resolution: The light was replaced and tested.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 July 2017 Resolved
Loose screws at the base of control console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 July 2017
Electrical › Electrical Distribution System (service) › Busway
Issued 26 July 2017 Resolved
Provide drain holes in PVC conduit every 5 feet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 July 2017
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 26 July 2017 Resolved
PVC electrical conduit is not sealed in engine room bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 July 2017
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 July 2017 Resolved
Conduct minor fiberglass repair in compartment fwd of e/r transom.
Action required: 705 - Other - as specified
Resolved 28 July 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 26 July 2017 Resolved
5 fittings on hydraulic lines are corroded and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 July 2017
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 July 2017 Resolved
Add positive shut off valve for the old generator overboard discharge line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 July 2017
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 July 2017 Resolved
Replace the faulty cooling water through hull valve for Port MDE as the current one does not fully close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 July 2017
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 26 July 2017 Resolved
After treating fuel in tanks, the high pressure fuel pump needed replacement.
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 6 August 2017
Engineering › Bilge Water Management System › Pump
Issued 11 July 2017 Resolved
Replace 03 non-UL submersible bilge pumps with UL-version (laz & E/R).
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 26 July 2017
Construction/Loadline › Structures › Deck Plating
Issued 11 July 2017 Resolved
Properly repair delamination in forward compartment.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 26 July 2017
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 July 2017 Resolved
Provide draft marks in accordance with 46 CFR 185.602.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 13 November 2017
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 July 2017 Resolved
Provide 2014 edition of NAV Rules.
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 26 July 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 August 2016 Resolved
Repair or renew the navigation light cover for portside (red) light.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: A new navigation light was installed.
Construction/Loadline › Structures › Superstructure
Issued 10 August 2016 Resolved
Properly repair the fractures located in the upper deck by the operating station for the awning framing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: All fractures identified during the inspection were repaired with a patch.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 August 2016 Resolved
VHF radio must be upgraded to VHF-DSC class A radio.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: A new radio compatible with their existing GPS was installed and MMSI number was entered. New radio was showing actual position during the test.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 August 2016 Resolved
Correct Emergency Instructions.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 31 August 2016
Resolution: New emergency instructions with current information were posted in the vessel in areas accessible to passengers.

Casualty record · 1

4 January 2019Routine · role: Involved in a Marine Casualty · activity 6647190
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.