ATLAS is a 2012 freight ship. The Coast Guard has recorded 5 inspections since 2014, most recently in May 2019, along with 3 deficiencies and 1 operational control.
Records from 2014 to 2019. Most recent: inspection, 3 May 2019.
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for ATLAS, retrieved 18 September 2026. mauryrecords.com/v/psix-1241077.html
Documentation record
Tonnage as PSIX records it88762 - Displacement, Metric Ton 75124 - Dead Weight, Metric Ton 41091 - Convention (Subpart B), Gross Ton 25573 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
3 May 2019Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6669224
22 March 2017Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6109666
19 June 2016Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5907503
28 October 2014Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5013958
5 August 2014ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4944361
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 3 May 2019Resolved
PSCO observed a blocking device (metal pipe) wired to the valve stem on the M/E HFO service tank quick closing valve and a metal object was observed in the valve on the MGO service tank, preventing valve from closing in the event of fire in the space.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2019
Resolved 11 May 2019
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 3 May 2019Resolved
Objective evidence was discovered in an expanded ISM exam revealing the following non-conformity: vessel failed to fully implement the requirments of the SMS as evident by deficiency #1 (fire safety). An external audit is recommended.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 15 May 2019
Resolution: Received, reviewed and accepted documentation stating corrective action has been implemented and audit will be conducted at next annual verification
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 19 June 2016Resolved
0750-Fire prevention-Doors required to be self closing shall not be fitted with hold back hooks. PSCO observed that the self closing fire rated door between the galley and the provisions identified on the fire control plan did nto self clease with the intalled mechanism, additionally a rope was being used to keep the door in the open position. SOLAS (14) II-2/9.4.2.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 19 June 2016
Resolution: Condition corrected on the spot. Rope was removed and closing device was repaired/adjusted to close fully.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.