MAURY USCG vessel records
← All vessels

MISTRAL I

MISTRAL I is a 2013 freight ship. The Coast Guard has recorded 9 inspections since 2017, most recently in February 2026, along with 7 deficiencies — 1 with no resolution recorded — and 5 operational controls.

Records from 2017 to 2026. Most recent: inspection, 11 February 2026.

Built
2013
Last inspected
11 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 February 2026
…with no type recorded4
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9650860
1241252
Flag
PANAMA
Maury page id
psix-1241252

Documentation record

Tonnage as PSIX records it81814 - Dead Weight, Metric Ton
96127 - Displacement, Metric Ton
44980 - Convention (Subpart B), Gross Ton
27045 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

11 February 2026 Deficiency Check · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8304114
17 October 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7566291
2 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6351986
15 February 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6356019
12 February 2018 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6354074
30 October 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6297405
24 October 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6294067
20 October 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6291550
19 October 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6285712

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 11 February 2026 Resolved
Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the fire safety systems code.. The connection shall be kept aboard the ship together with a gasket for both the port and starboard international shore connection. Solas 74 (Cons.), II-2/10.2.1.7, FSS Code CH. 2/2.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 February 2026
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Gasket has been installed on both port and starboard international shore tie connections.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2026 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed exposed electrical wires on the stern light fixtures. Conduct repairs prior to cargo operations. 74 SOLAS (Cons.) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2026
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. The panels on the electrical covers have been re-installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2026 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the administration. PSCO observed a approx. 10 inch crack in the port side electrical conduct box between cargo holds #4 and #5. Conduct repairs prior to cargo operations. 74 SOLAS (Cons.) II-1/45.5.4
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2026
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified.Crack on the electrical conduct box has been repaired via re-welding by the crew.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 February 2026 Resolved
Fire protections systems and firefighting system and appliances shall be maintained ready for use. PSCO observed a bag covering the engine room workshop smoke detector. 74 SOLAS (cons.) II-2/14.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 11 February 2026
Resolution: Bag removed and operation of the smoke detector witnessed by PSCO.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 11 February 2026 No resolution recorded
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical nature of the deficiencies 03 and 04 provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit report satisfaction to the OCMI must be submitted within 90 days prior to clearance of this deficiency. 74 SOLAS (Cons.) IX/3 ISM Code 10
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 October 2022 Resolved
The purpose of this regulations is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed several areas where the accumulation of oil and oil leaks were present in the purifier floor. Overflow piping near seachest, main engine fuel return line #1-#6 74SOLAS(20), II-2/Reg 4.1.1 - 17 a,c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2022
Resolution: RECEIVED, REVIEWED AND ACCEPTED CLASS REPORT FROM BV STATING THAT ALL OIL IN E/R HAD BEEN CLEANED AND NO ACTIVE LEAKS WERE FOUND.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 October 2022 Resolved
All steering gear component and rudder stock shall be of a sounds and reliable construction to the satisfaction of administration. In local control on the #1 steering gear pump, PSCO observed the rudder drifting to starboard one degree every twenty seconds. 74 SOLAS(20),II-1/29.2.1 - 17 a, c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2022
Resolution: RECEIVED, REVIEWED AND ACCEPTED CLASS REPORT FROM BV STATING THAT STEERING GEAR DRIFT WAS FIXED BY ADJUSTING THE SERVO PUMP PRESSURE. STEERING GEAR WAS TESTED FROM BRIDGE AND LOCALLY AND FOUND TO BE OPERATING PROPERLY.

Ownership record